Web Analytics Made Easy - StatCounter

Vacuum Controller Tenders

Get complete information related to latest Vacuum Controller Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Controller Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Controller Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45491008 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : repair/ maint and replacement of unsv street lights, perimeter light, flood light, timer panel, pole box and related items under ge (af) jorhat

Central Government/Public Sector

CTN :45733913 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For repair/maint to various types of lights fitting, s/l panel, feeder pillar box and other connected works at pocket a at patiala under ge (south) patiala

Central Government/Public Sector

CTN :45582056 Due date: 14 Jul, 202614 Jul, 2026 49.00 Lacs
Tender For corrigendum : repair/maint and improvement of lt distribution network, lt panel, fp box and other allied works in sector c and sector d md accn in army area under ge (a) no.1 jodhpur

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

CTN :45711090 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109

CTN :45551266 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr

CTN :45292709 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For bid to ras supply of coducter complete set with all accessories , pvc armoured cable 16 sqmm 4 core make havells comma finolex comma polycab , mcb box 8 way make l and t comma usha comma cg , recess mounting light 2 x 2 make bajaj comma crompton comma philips comma cg , ceiling fan 1200 mm sweep make bajaj comma usha comma cg comma khaitan , ms hook 12mm rod for fan , led tube light 20 watt 4ft complete make bajaj comma usha , led bulb 10 watt make philips comma anchor comma bajaj , exhaust fan 300 mm make philips comma anchor comma bajaj , mcb 63 amp make philips comma anchor comma bajaj , mcb 40 amp make philips comma anchor comma bajaj , mcb 5 to 30 amp make philips comma anchor comma bajaj , mcb 16 amp make philips comma anchor comma bajaj , cooler motor 6100rpm desert cooler 450mm make philips comma usha comma bajaj , desert cooler motor make philips comma usha comma bajaj , desert cooler water pump make philips comma usha comma bajaj , ceiling rose , pvc cable xlpe 25 sqmm 4 core make havells comma finolex comma polycab , led tube light fitting 10 watt 2 ft complete make bajaj comma usha , switch socket combination 15 amp make anchor comma bajaj , switch socket combination 5 amp make anchor comma bajaj , desert cooler 6100rpm make philips comma usha comma bajaj , switch 15 amp modular type make bajaj comma philips comma siemens comma anchor comma equivalent isi marked , bulk head fitting make philips comma bajaj , pvc swithc board 7 inch x 4 inch make anchor comma bajaj , pvc swithc board 10 inch x4 inch make anchor comma bajaj , socket 15 amp make anchor comma bajaj , flood light 100w make philips comma bajaj , security light 100w make philips comma bajaj , ro membrane for 1000lph make adelino comma leo comma cg comma kirloskar , fuel filter for 62 point 5 kva make kirloskar , oil filter for 62 point 5 kva make kirloskar , fan belt for 62 point 5 kva make kirloskar , oil temp guage for 62 point 5 kva make kirloskar , oil pressuer guage for 62 point 5 kva make kirloskar , exhaust fan for 62 point 5 kva make kirloskar , fuel guage for 62 point 5 kva make kirloskar , battery 12 v150 ah make exide comma amaron , engine oil make castrol , fuel filter for 30 kva make kirloskar , oil filter for 30 kva make kirloskar , fan belt for 30 kva make kirloskar , air filter paper type for 30 kva make kirloskar , panel box repair make kirloskar , alternator winding 62 point 5kva make kirloskar , router winding 62 point 5kva make kirloskar , excider winding 62 point 5kva make kirloskar , avr card make kirloskar , diode make kirloskar , starter motor repair make kirloskar , flywheel ring gear make kirloskar , fuel pipe make kirloskar , alternator winding 30kva make kirloskar , rotor winding 30kva make kirloskar , exciter winding 30kva make kirloskar , change over switch 100amp , submersible pump rewinding , change over switch 64amp

CTN :45438320 Due date: 06 Jul, 202606 Jul, 2026 45.00 Lacs
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box

Central Government/Public Sector

CTN :45469070 Due date: 02 Jul, 202602 Jul, 2026 6.75 Crore
Location: Goa - Goa Goa - Goa
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be

corporations/Associations/Others

CTN :45712936 Due date: 13 Jul, 202613 Jul, 2026 19.20 Lacs
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
 Loading, Please wait...

Connect us via What's Up