Get complete information related to latest Vacuum Crystallizer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Crystallizer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Crystallizer Tenders.
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuumcrystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For supply of cartridge for active inlet valve 600bar , solvent inlet filter, stainless steel , standard flow cell 10mm, 13ul, 120bar , quick-connect heat exchanger large id , loop st , ferrule , tube peek 0.18x5000mm, 1.6mm , peek fitting finger , ro membrane and integrated pretreatment for smart2pure system , polishing cartridge for smart2pure system , ro membrane filter for ro water purification system , acrylic ftir enclosure for ac room
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref