Tender For machinery equipments for laundry plant - hygienic barrier washer extractor 15 kg, fully automatic washer extractor 130kg, fully automatic washer extractor 60 kg, fully automatic washer extractor 11 kg, industrial drying tumbler (11 kgs), industrial drying tumbler (60 kgs), industrial drying tumbler (30 kg), flat work ironer (roller heated) ( single roll - front feed and rear return)- roller dia 600 mm x roller length 3000 mm, flat work ironer (roller heated) ( single roll - front feed and front return)- roller dia 400 mm x roller length 1600 mm, general utility press, vacuum ironing table with steam press, electric boiler (18 w), electric boiler (60 w), sewing machine, mobile table (10x2.5), mobile table (4x2.5), dry linen trolley, wet linen trolley, spotting machine (with sink), scrubbing station (double sink), shelf trolley, air compressor (3 hp)
Tender For custom bid for services - process plant activities for transformer manufacturing-work: process (heating +vacuum) plant activities a. for plant in trm (instr trfr) div. a. preparation for vacuum in ct, b. leakage checking of vacuum in ct, c. monitoring of vacuum/ heating in ovens of ct & cvt lot, d. oil preparation for oil filling (circulation & coordination of testing of oil), e. disconnect the vacuum pipes of cts, f. topping up of oil in cts, g. oil sampling for parameter check, h. process record. b. for various plants in cpm/bcm div. process operations of 7nos process plants, 5nos ovens and 3nos. filtration plant in cpm division and 7nos process plants, 8nos ovens and 2nos. filtration plant in bcm division for 24 hrs continuous processing including sunday & holiday. general processing work will be as follows for all plants:- (a) temperature & vacuum recording as per desired proforma, (b) flooding operations (firm has to perform above activities in any combination depending upon shop requirement as desired by shop executive) 3. quantity: 29,664 technology hours..
Tender For corrigendum : supply of sewage treatment plant and vacuum toilet system for yard - stp with vacuum toilet system_321000000013_2121 , wc-white vitreous china- with accesories_321006000018_2121 , 20 tph sewage discharge pump_321000000014_2121 , obs for stp and vts_321000760065_2121 , tools for stp and vts_321000770006_2121 , documentation for stp and vts_321000810013_2121 , instl and comm spares for stp and vts_321000820005_2121 , training for stp and vts_ser10640_2121 , service of engineers_ser10641_2121 , warranty extension charge for 1st year_2121 , warranty extension charge for 2nd year_2121
Tender For corrigendum : deposit-air vacuum plant -additional electrical works in air vacuum plant govt. medical college hospital, manjeri, malappuram.-general electrical work
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th