Get complete information related to latest Vacuum Pumps Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Pumps Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Pumps Tenders.
Tender For e- tender for nctps i - se/mi circle aoh (25-26) - tm dn. fws overhauling of boiler feed booster pump, cep andcondenser vacuumpumps and its auxiliaries in feed watersystem in unit i, ii & iii during overhaul work for the year 2025- 26
Tender For corrigendum : miscellaneous works during overhauling of turbine side auxiliaries and equipments such as bfps booster pump hydraulic coupling ceps and vacuumpumps phes valves etc of unit 9 of dtps kasimpur aligarh
Tender For nctps i se mi circle aoh 25 26 tm dn fws overhauling of boiler feed booster pump cep and condenser vacuumpumps and its auxiliaries in feed water system in unit i ii iii during overhaul work for the year 2025 26
Tender For carrying out mechanical maintenance works of turbine, ms & hrh strainers, hpbp, lpbp, auxiliaries like cep, bfp, drive turbine, lops, vacuumpumps, dmcw-sg & tg pumps, dozing pumps, compressors, heat exchangers, hotwell pumps, cw & acw pumps, eot cranes & monorail hoists of above system in unit-i, ii (2x500mw) & iii (1x700mw) of btps for a period of one year.
Tender For corrigendum : supply of hei standards and typical specifications for tray type deaerators, 11th edition, 2023 , hei standards for steam surface condensers, 12th edition, 2017 , hei performance standard for liquid ring vacuumpumps and compressors, 5th edition, 2017
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and