Get complete information related to latest Vacuum Tube Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Tube Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Tube Scrap Tenders.
Tender For supply of lt enabled terrain modelling video conferencing system , intel core ultra 7 270k plus, 32 gb, 1tb ssd, gpu 16gb , high resolution video conferencing 4k camera , audio conferencing system , 16 port matrix switcher , miscellaneous equipment , ups on line 20kva 20kw , lnstallation and commissioning
Tender For e.i. work/providing shed (foundations) for placing the ht/lt equipment for the work augmentation of electrical system at main pump house (replacement of main panel, starter panel with drive panel for smooth operation) in pu campus sector 14 chandigar
Tender For providing of operation and maintenance of substation - round the clock operation and comprehensive annual maintenance contract of different type of electrical substation equipment transformer breaker panel & lt/ht cable (33/11kv, 0.440 kv and line distribution at government medical college, budaun
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be
Tender For auction sale of depot ferrous scrap - cond. and u/s ferrous fabricated materials of ms/ci scrap in nature such as weld mesh, ms duct, anti slip arrangement, earthen bond, galvanized (gi) sheet, ms sheet of various sorts and sizes, blower rotary forging, liner, guide fixtures, side frame fixtures, trolley of various sorts and sizes, trolley wheel & frame, battery fixing iron tray, ms pipe, coach/wagon stand, conveyor belt, ferrous body of auto change over panel, wire mesh, emu coach cut parts, ferrous portion of cab window assembly, sign on iron stand,castiron tems,girder base with concrete adhearings,gearset,grill,vcb panel boxes,gipipes,nuts and bolts,angles,rails,panel boxes,fissureplates,wheels,cupboard, structural items, different type of packing channels, trolley, lat, coach cut up parts, head stock, ms tank, grill gate, rolling shutter,wheel with plate, bins,regulator empty box, dolley, fob fencing, corrugated sheets, rectangular square tube &galvanised sheets, bogie mounted brake beam,brake blocks, gi sheets, pipe,square &rectangular tubes,stair case and handle,ferrous body of various types of motor, angle and channel fabricated with nut, bolt with or without brick and concrete,ladder,plate,grill, barricade, bolts, nuts, tray under frame, cut rod, rails of various sorts and sizes with/without concrete/brick/mud adhering,cut rails or rails used in support structures, coach head stock, coach parts,battery tray, ladder, all types of trolley wheels with minor nfs attachments, screens, channel post, sheets, stand, track machine cut up parts, ms pipes covered with or without rope &with or without parts of rubber, dome, vrla rack, vcb in dismantled condition, vrla battery box & clamp, stand, dtmf way station equipment box, led line display board, hydraulic lifting table with available fittings, vrla battery empty container, bed/base plate, fabricated cut rods,gi pipes, ci pipes and fittings, ms plate, roofsheets, angle, plate, platform bench, spring plank, clamps, cabinet, ms grill, sheets, ladder, steel gate, trolley,ms water tank, fire tender tank,roof truss supporting columns,purlins, sand box, fencing, tl rod, vcb panel, train display board, battery stand, boards, tools box, empty regulator &empty battery container, cut rod, ticket punching cut parts, hand rail, fabricated post/pipe/rod, strips, hoods, impellor, base plates, meshes, battery box frame, grs box, control panel, fan down rod, ac window covers ,angle / channels with/without rails, angle of tld, rack, lt panels, ferrous electrical panel boxes,i beam,transmission rods,fissure plates, main switch panel board w/o nfs attachments, ebc & rbc frame &enclosure,emu sliding door, high beam, silencer, , garden light post, tap changer cover with fiber attachments, empty battery container, stretcher, cupboard, dust bin, iron step, empty rotary junction box, empty regulator box, iron metal box, air reserviour compressor cylinder of varous sorts & sizes, garden light post, stand, mdb w/o non ferrous attachments, st light tubular post, gi/ms window, luggage rack, ,bed portion of weighing scale l with or without any minor non-ferrous attachments and all other scrap excluding ms hand hold in fabricated nature of sorts and sizes full/broken with/without other fs/ci/gi fittings in as is where is condition.pl no 98050126. note:(1) cutting is permitted to loadable size and for heavy nature items only. 2) during delivery if any major non-ferrous items found the same may be handed over to custodian. 3) jcb/crane loading permitted. location: (1)behind a row bin 3&4, (2)near old e-ii ward annexe
Tender For supply of ecsg 75 mm dark brown , ecsg 75 mm lt green , ecsg 50 mm light green , ecsg 50 mm grass green , ec net jute , equipment camouflage net pin iron
Tender For corrigendum : expression of interest (eoi) from any reputed manufacturers for budgetary quotations for supply of electrical equipment materials within the jurisdiction of dhbvnl on for destination basis- heat shrinkable termination kit for 11 kv xlpe cable (outdoor type) , 3cx50mm2 , 3cx95mm2 , 3cx120mm2 , 3cx185mm2 , 3cx300mm2 , 3cx400mm2 , scx630mm2 , heat shrinkable termination kit for 11 kv xlpe cable (indoor type) , 3cx50mm2 , 3cx95mm2 , 3cx120mm2 , 3cx185mm2 , 3cx300mm2 , 3cx400mm2 , scx630mm2 , 11 kv 3/c cable heat shrink type straight through joint of sizes , 3/cx50mm2 cable , 3/cx95mm2 cable , 3/cx120mm2 cable , 3/cx185mm2 cable , 3/cx300mm2 cable , 3/cx400mm2 cable , s/cx630mm2 cable , sleeve , sleeve, 11 kv insulated medium voltage line cover (mvlc) for acsr conductor (sleeve) suitable for size upto 100 mm2 as per nigam's technical specification /relevant iss and latest amendments thereof , un-armoured copper control cable , 2c x 4mm2 , 2c x 6mm2 , 3c x 4mm2 , 4c x 4mm2 , 6c x 4mm2 , 7c x 2.5mm2 , 10c x 2.5mm2 , lt xlpe armoured cable , lt xlpe mm2 cable un-armored 1c*300 , lt xlpe armoured 2c*16 mm2 cable , 33 kv ht tr-xlpe cable , 3/c 300mm2 , 3/cx400mm2 , 11 kv h.t. tr-xlpe cables , 11 kv 3c*400 mm2 tr-xlpe armoured cable(hdpe extruded cable duct) co- , 11 kv 3c*300 mm2 tr-xlpe armoured cable(hdpe extruded cable duct) co-, , 11 kv 3c*185 mm2 tr-xlpe armoured cable(hdpe co-extruded cable duct), , lt feeder panel and lt switchgear, , 400 amps acb, 4 pole, manual operated, fixed type with enclosure, , 200 amps mccb with enclosure, , 100 amps mccb with enclosure, , 7 way distribution feeder panel with 2 nos. mccbs, 4 pole, 3phase, 415 v, 400 amps for incoming and 5 nos. outgoing mccbs 4 pole, 3phase, 415 v, 100 amps rating type suitable for outdoor installation, in accordance with technical specification (type-d), , 33 kv rmus, , outdoor type 33 kv sf6 type extensible and motorized 5 way rmu (2lbs+3vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts, , outdoor type 33 kv sf6 type extensible and motorized 5 way, , outdoor type 33 kv sf6 type extensible and motorized 4 way rmu (2lbs+2vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 4 way rmu (2lbs+2vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (2lbs+1vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (2lbs+1vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (1lbs+2vcb) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (1lbs+2vcb) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (3lbs) with fpi as per is (without frtu) with the provision of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 3 way rmu (3lbs) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) with the provision, , of self-powered supply through 1 kva aux transformer (33/0.230 kv) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) as per ts., , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (2lbs) with fpi as per is (without frtu) as per ts. (both side extensible), , outdoor type 33 kv sf6 type extensible and motorized 2 way rmu (1lbs+1vcb)
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp