Get complete information related to latest Valve Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Valve Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Valve Relay Tenders.
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For tmb part no 2520 012589 slave cyleender , tmb part no 2641 2910 0117 clutch master cylender 90 point 5 dia , stln part no 5930 72 0466969 2 pole isolate switch , tata part no 2154 8110 6903 grab handle rh , tata part no 2564 7230 0130 assy inner handle lh , desire wiper blade , desire bumpper front , desire radiator fan , desire motor radiator , tata part no 2574 5420 9915 temp transducer , stln part no f 4650510 mounting bracket , stln part no 2530 72 0461342 valverelay air pressure , stln part no 2530 018232 valverelay air pressure , hmv part no 502442100135 assy spring brake actuator typ , hmv part no 502442100136 assy spring brake actuator typ , hmv part no 501726800103 assy pressure regulator 5 point 5 bar , stln part no 4320 004124 ram hydraulic ram assy , desire bonnet lock , desire beading , desire clutch cable , desire clutch release brg , hmv part no 987 0610 high pressure hose * /bid number : gem/2026/b/7654652 + /dated: 11-06-2026 ' ' / bid document 1 / 19
Tender For corrigendum : : work of maintenance of various equipment’s at 33 kv control panel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).
Tender For technical bid for supply of hvac operational spares , bearing (6206) size: od, 60 mm x id 50 mm ball bearing desig: 6001-z, ball bearing desig: 6307/2z c3 universal hvac/r controller, armoured 4 core x 6 sqmm xlpe copper cable. 1 sqmm frls multi stranded copper cable (single wire), 10 sqmm frls multi stranded copper cable (single wire) 4 sqmm frls multi stranded copper cable (single wire), fibre glass insulated copper wire for heater size: 6 sqmm, alkaline battery volt: 9vf sealed maintenance free (smf) lean-acid battery 7ah 12v, brush width: 3 inch for painting work. loctite 495 adhesive, kiwi drain cleaner heavy duty industrial safety gloves - cut-resistant (mechanical work), spray foam insulation (pfu) can qty: 750 ml wd 40 multipurpose spray size: 500 ml, green paint (bus green synthetic enamel black paint (synthetic enamel), ms flat bar size: 40 x 5 mm ms l- angle size: 25 x 25 x 5 mm, ms l- angle size: 40 x 40 x 5 mm metal primer (red oxide), black color spary paint 400 ml thread repair helicoil insert ss-m18 x 2.5mm x 1.5d, thread repair helicoil insert ss-m20 x 2.5mm x 1.5d thread repair helicoil, insert ss-m24 x 3mm x 1.5d thinner for oil-based paints, wire type buffing whee bench grinder wheel -heavy grade, dial test indicator (dti) gauge with flexible stem magnetic base stand, digital clamp meter capacity: 600a ac trms heavy duty exhaust fan, size: 9 inch backward curved fan with motor size: 355, mm dia ventilation fan for electrical panel sweep, dia: 12 cm induction motor fan, blade shaft size: 20 mm & blade dia: 130 mm, induction motor fan blade shaft size: 25 mm, & blade dia: 110 mm gi 6 mm x 25 mm bolt & nut with washer, anchor bolt with nut & washer size: 10 mm anchor bolt with nut &, washer size: 8 mm anchor fastner size: 10, mm for threaded rod gi self tapping screw, size: 3/4 inch (20 mm) head type: truss, pop screw size: 1 inch (25 mm) head type: flat (csk). ss self tapping screw size: 2 inch (50 mm), head type: hex din rail size: 35 x 7.5 mm, add on auxiliary contact block (1 no +1 nc) casing and capping size: 20mm (3/4 inch), casing and capping size: 50mm (2 inch) copper strip for electrical motor size: 25 x 3 mm, current transformer (for mfm/ammeter), ratio: 10/5a current transformer (for mfm/ammeter), ratio: 15/5a, current transformer (for mfm/ammeter), ratio: 20/5a current transformer (for mfm/ammeter), ratio: 30/5a, current transformer (for mfm/ammeter), ratio: 5/5a emergency stop switch, metal enclosure electrical junction box, size: 200mmx200mmx150mm, metal enclosure electrical junction box size:, 300mmx300mmx200mm three pole neutral (4p), 32 amps miniature circuit breaker (mcb) 4-way mcb metal enclosure, 2- module surface mounted pvc box. thermal overload relay, range: 14-23 amps electronic fan regulator, single module porcelain heater insulators or terminal. blocks, led indicator color: amber pin type lug size: 1.5 sqmm, pin type lug size: 2.5 sqmm pin type lug size: 4 sqmm, pin type lug size: 6 sqmm spade type lug size: 1.5 sqmm, spade type lug size: 2.5 sqmm metal flexible conduit size:19, motor protection circuit breaker (mpcb) range: 6.3-10 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 2.5 amps (rotary), motor protection circuit breaker (mpcb) inst trip rating: 25 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 50 amps (rotary), ms conduit size: 25 mm motor terminal block range: 10 hp/7.5 kw, motor terminal block range: 40 hp/30 kw thermal overload relay(olr) range: 20-33 amps, thermal overload relay(olr) range: 42-69 amps plug top 3 pin capacity: 5 amps, 4 pole power contactor capacity: mnx 12 4 pole power contactor capacity: mnx 18, 4 pole power contactor capacity: mnx 9 push button (illuminated) color: green, push button (illuminated) color: red plugable interface relay (4 c/o, 230 vac) with base, plugable interface relay (4 c/o, 24 vac) with base analog timer controller for split ac's, terminal block range: 0.2-2.5 sqmm,