Get complete information related to latest Valve Rotator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Valve Rotator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Valve Rotator Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For supply of screw compresor boq b b - air filter, part no. 39588777 , coolant filter element, part no. 39907175 , separator element, part no. 54595442 , blowdown solenoid valve, part no. 22124085 , kit high air temperature switch, part no. 37952264 , minimum pressure check valve, part no 70662416 , temperature sensor, part no 37952439 , v belt, part no 54524343 , gas spring, part no 39592951 , element thermo valve, part no 39441944 , inlet valve, part no 39840418 , shaft seal kit , part no 42486597 , kit unloader repair, part no 42385948 , belt, in 15 by 7 bar, part no. 54400726 , element separator, part no. 22388045 or 24121212 , element oil filter, part no. 39329602 , element air filter , part no. 88171913 , elbow 1by4 inch bspt x 6mm, part no. 54403266 , kit rebuild mpcv, part no. 18983262 , kit inlet valve rebuild sd, part no. 18983700 , switch pressure 7 bar in 7.5-15, part no. 70278999 or 23672744 * /bid number : gem/2026/b/7714185 + /dated: 26-06-2026 ' ' / bid document 1 / 24
Tender For supply of tata safari compressor and ac gas pipe repair , ciaz wiper blade motor repair , fly wheel skimming of tata 2.5 ton , repair of pressure valve of tata 2.5 ton , repair of re piston head injector nozzle
Tender For annual maintenance contract of hvac and drinking water equipments at rmc parel mumbai 400 012 - deep freezers, capacity up to 500 itrs. (below 0 cto-75 °c), quantity - 8 nos. , refrigerators, capacity up to 400 ltrs. quantity -23 nos., , exhaust blower with ms casing on terrace (size & make - as per existing site), quantity - 2 nos., , fan coil units (above false ceiling/high wall mounting), capacity up-to-3tr, quantity - 12 nos., , servicing/breakdown repair of following electrical and water related equipments as per technical specifications., , refrigeration type water coolers (qty-4 nos.), , water purifier of various makes of barc based technology like jaltara/rupali/dolphin/nirmal aqua as per tender specifications. (qty-18, handset with dry cell for split or window air-conditioners, capacity-2.0tr, , metallic capacitor (approx. 50 microfarad), , replacement of rotary compressor (upto 2.0 tr capacity) of window & split type air conditioners with new compressor including dismantling of defective compressor, installation of new compressor, vacuuming, leak testing, gas charging, testing & commissionine as ner technical specifications., , supply, installation, testing & commissioning of following equipments as per technical specifications., , 3 stage water purifier based on barc developed technology, , fan coil units, upto 3 tr capacity, , fan filter units, 2 x 4 ft size, , plastic jar with float valve, , fabrication, supply and installation of ms structure as per technical specifications., , replacement of old candles of water purifier with following new ones as per technical specifications., , prefilter paper candle, , membrane candle, , carbon candle, , odour candle
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia