Get complete information related to latest Valves Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Valves Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Valves Repair Tenders.
Tender For supply of flash back arrestor (dry type) for regulator end of oxygen lines to prevent flash backs in oxy fuel system conforming to en 730/iso 5175-1/is 11006 standards with flame arrestor (fa) andnon return valve (nrv) and thermal cut off valve (tv). working pressure: 15 bar. end connections g 3/8" rh to en 560/iso 3253 standards. make: messer (dgn oxy) or esab (protex ro) or gce (fr-34 r oxy) or witt (oxygen rf53n) only. [ warranty period: 30 months after the date of delivery ]
Tender For repair maintenance of distribution pipe line valves, repair to valve pits at shikargrah and other area under ge (army) no 2 jodhpur as per cpp ser no 08
Tender For supply of 2.flash back arrestor (dry type) for regulator end of acetylene/lpg lines to prevent flash backs in oxy fuel system conforming to en 730/ iso:5175-1/ is:11006/2011,(ra2021),amd-1 of dec.2013 standards with flame arrestor (fa) and non-return valve (nrv) and thermal cut off valve (tv) working pressure: 1.5 bar for acetylene/5.0 bar for lpg. end connections g 3/8" lh to en 560/iso 3253 standards. make: messer (dgn fuel) or esab (protex ra) or gce (fr-34 r fuel) or weldstar or witt only. note:1) offers of oems or their authorised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppliers shall send test certificate from govt. authorised test house. in case of international brand, the test certificate from reputed institute like bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash back arrestors and calibration. the purchaser has the right to inspect these installations. as per specn. en 730/iso 5175-1/is 11006/2011,(ra-2021), amd-1 of dec 2013 [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of repair minor maintenance of complete electrical system at awrs etp , removal reinstallation replacement of 0. 4 kv, 160 to 200 kw motors , removal reinstallation replacement of 0. 4 kv, 130 kw motors , removal reinstallation replacement of 0. 4 kv, 30 kw motors , removal re-installation replacement of 0. 4 kv, 0. 7kw to 5. 5 kw motors , servicing maintenance of bearings testing of 0. 4 kv 130 kw motors , servicing maintenance of bearings testing of 0. 4 kv 130kw upto 200 kwl motors , servicing maintenance of bearings testing of 0. 4 kv 375 kw motors , servicing maintenance of bearings testing of 0. 4 kv 30 kw motors , servicing maintenance of bearings testing of 0. 4 kv 0. 7kw to 5. 5 kw motors , servicing maintenance testing of modules of motors incomer section up to 200 kw , laying of l. t power cable 3c x 26 to 240 mm2 3. 5c x 25 to 185 mm2 , aying of l. t power cable 1c x 1000 mm2 2c x 400 mm2 , end termination of power cable 3c x 26 to 240 mm2 3. 5c x 25 to 185 mm2 , end termination of power cable 1c x1000 mm2 2c x 400 mm2 , oh cleaning reconditioning 200ah- 600ah batteries 350v-360v dc , load test for various size battery of ups , oh of bus bars tightness checking and replacement of damaged switches , cleaning and painting of the wooden battery stands of ups , amc of air conditioners repairing and servicing , gas charging work of ac , rewinding of burnt fan motor of air conditioners , repairing of actuators of nozzle valves , repairing of flame scanner system , repairing of hea system , repairing of solenoids of hag , repairing of actuators had and cad , repairing servicing and installation at site of atomizing steam nozzle valve ) /bid number: gem/2026/b/7314308 * /dated: 05-03-2026 & & / bid document1 / 27
Tender For supply of flash back arrestor(dry type) for torch end of acetylene/lpg lines to prevent flash backs in oxy fuel system conforming to en 730/iso 5175-1/is 11006/2011, (ra-2021), amd-1 of dec-2013 standards with flame arrestor (fa) and non return valve (nrv) working pressure: 1.5 bar for acetylene/5.0 bar for lpg. end connections g 3/8" lh to en 560/iso 3253 standards. make: messer (cg-91 fuel) or esab (fr-18) or gce (fr-20t fuel) or weldstar or witt only. note:1) offers of oems or their authorised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppliersshall send test certificate from govt. authorised test house. in case of international brand, the test certificate from reputed institute like bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash back arrestors and calibration. the purchaser has the right to inspect these installations. as per specn. en 730/iso 5175-1/is 11006/2011, (ra-2021), amd-1 of dec-2013 [ warranty period: 30 months after the date of delivery ]
Tender For supply of flash back arrestor(dry type) for torch end of acetylene/lpg lines to prevent flash backs in oxy fuel system conforming to en 730/iso 5175-1/is 11006 standards with flame arrestor(fa) and non return valve(nrv) working pressure: 1.5 bar for acetylene/5.0 bar for lpg. end connections g 3/8" lh to en 560/iso 3253 standards. make: messer(cg-91 fuel) or esab(fr-18) or gce(fr-20t fuel) only. note:1) offers of oems or their authorised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppliers shall send test certificate from govt. authorised test house. in case of international brand, the test certificate from reputed institute like bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash back arrestors and calibration. the purchaser has theright to inspect these installations. as per specn. en 730/iso 5175-1/is 11006 [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of a set of flash back arrestors (dry type) suitable for use in oxy-fuel gas cutting/welding systems, for both oxygen and fuel gas (acetylene/lpg/bcg) lines, for installation at torch end and regulator end, to prevent flash backs. the flash back arrestors shall conform to en 730 / iso 5175-1 / is 11006:2011 (ra-2021), amendment-1 of december 2013 standards. one set shall consist of four (04) numbers of flash back arrestors, comprising one(01) number for oxygen regulator-end installation ,one(01) number for fuel gas (acetylene/lpg/bcg) regulator-end installation, one (01) number for torch-end installation for oxygen supply and one(01) number for torch-end installation for fuel gas (acetylene/lpg/bcg) , as applicable. the flash back arrestor shall be provided with flame arrestor (fa) and non-return valve (nrv) as minimum safety features. for regulator-end applications, the flash back arrestor shall additionally be provided with a thermal cut-off valve (tv). end connections shall be g 3/8" threads conforming to en 560 / iso 3253 standards, suitable for right-hand (rh) threads for oxygen line connections and left-hand (lh) threads for fuel gas (bcg/acetylene/lpg) line connections, as applicable. the working pressure and configuration shall be suitable for oxygen lines (up to 15 bar) and fuel gas lines (1.5 bar for acetylene / 5.0 bar for bcg/lpg) as per application. accepted makes shall be of messer / esab / gce / weldstar / ador/witt. offers shall beaccepted only from oems or their authorized dealers. valid authorized dealership certificate shall be enclosed. suppliers shall submit test certificates from a government-authorized test house. in case of international brands, test certificate from a reputed institute such as bam, germany is mandatory. suppliers shall possess in-house facilities for testing and calibration of flash back arrestors. the purchaser reserves the right to inspect these facilities. note: four (04) samples shall be supplied in advance and suitability approval fromthe consignee shall be obtained before commencement of production and bulk supply. [ warranty period: 12 months after the date of delivery ]