Web Analytics Made Easy - StatCounter

Variable Frequency Drive Panel Tenders

Get complete information related to latest Variable Frequency Drive Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Variable Frequency Drive Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Variable Frequency Drive Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40428054 Due date: 19 Jun, 202519 Jun, 2025 NA
Tender For supply of 200 tr cooling tower with 5.5 kw variable frequency drive panel

CTN :40344961 Due date: 05 Jun, 202505 Jun, 2025 2.22 Lacs
Tender For supply of sterile water 500ml bottle , t-piece resuscitator with adjustable peep controller disposable circuit , air vo2 tubing with humidifier infant

Central Government/Public Sector

CTN :40329148 Due date: 26 May, 202526 May, 2025 NA
Tender For supply of fully automatic star delta smart controller suitable for 25 hp pump/motor 3 phase, 415v ac, 24-42 a with in built antith eft protection, dry run, locked rotor & short circuit protection, voltage & current based protection, hour based & real time clock based t imer with line voltage, phase current, power factor, energy metering, total run time of pump. complete operation (remote on/off) thro ugh sms or ltlk mobile connect mobile app or ivrs in hindi & english language, micro controller based technology. [ warranty peri od: 30 months after the date of delivery ]

Central Government And Public Sector

CTN :40329622 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For supply and commissioning of oil chiller unit with the following specification: (1) rated operat ing voltage: 3phase, 415 v ac, 50 hz (2) nominal cooling capacity: 9,000 kcal/h/10.4 kw/3.0 tr (3) refrige rant used: r-407c or any environmental friendly refrigerant with lesser gwp. (4) medium of cooling hydrau lic oil viscosity grade: is0 vg 32 to 68 cst @ 40-degree c (5) duty type: indoor, continuous duty type (6) p umping capacity: minimum 40 lpm, geared pump with 3 phase, 415 v ac, motor (7) tank: without storage tank (8) temperature range ambient: +15-degree c to +45-degree c (9) temperature range of medium: + 15-degree c to +35-degree c (10). oil connection both suction & delivery: 1" bsp (11) type of enclosure: i ndustrial enclosure (12) compressor: hermetically sealed, air cooled, reciprocating/scroll compressor. (13 ) condenser: air cooled condenser, made of copper tube with aluminium fins, air inlet from the side & air o utlet on the top. (14) evaporator: stainless steel brazed plate heat exchanger (15) drier: filter drier (16) ex pansion device: expansion valve (17) pressure switches: low/high pressure switches (18) temperature co ntroller cum display unit: microprocessor based, programmable controller with digital display (19) auxiliary contact: potential free contact for general alarm 1 no & 1nc (20) motor protection: all motors with motor p rotection circuit breaker (mpcb). (21) conforming to ce compliance. [ warranty period: 12 months after t he date of delivery ]

CTN :40329853 Due date: 19 May, 202519 May, 2025 NA
Tender For supply, erection, installation, commissioning and testing of 132kw vfd (variable frequency drive) panel with 132 kw hd vfd as per details technical specifications and features attached in annexure -a. [ warranty period: 30 months after the date of delivery ]

CTN :40254432 Due date: 17 May, 202517 May, 2025 NA
Tender For supply of p. c. b. of xeno alpha+ (amtek make) fadeometer , power supply circuit board for xeno alpha+ (amtek make) fadeometer , board drive controller for xeno alpha+ (amtek make) fadeometer , quartz filter for xeno alpha+ (amtek make) fadeometer , xenosensive for xeno alpha+ (amtek make) fadeometer

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
 Loading, Please wait...

Connect us via What's Up