Get complete information related to latest Variac Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Variac Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Variac Tenders.
Tender For corrigendum : supply of 1250kva,415v/0-470v,1600amps per phase, 3-phase variable auto transformer or variac or dimmerstat for conducting hv test(forward charging) at dr. nttps
Tender For supply and fitment of 3 phase variac (dimmer) input : 0-415 volt ac , output : 440 v ac enclosed in a box. as per attached specification. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of set of items consisting:- (1) variable ac regulator variac/dimmerstat/auto transformer singlephase 220v-230v 10 ampere closed type, make-vevor, crown, denko or similar, qty- 04 nos. (2) dc voltmeter analog panel voltage gauge volt meter 2.5% error 0-150v, make- siemens, l&t or similar, qty-02 nos. (3) dc ammeter analog panel meter amp meter current panel meter gauge 0-30a(75mv) make- siemens, l&t or similar, qty-02 nos. (4) analog voltmeter(0-500v) ac 72mm size singel (v) meter. make- siemens, l&t or similar, qty-02 nos. (5) analog amper meter (0-30a) analog voltmeter (0-500v) ac 72mm. make- siemens, l&t or similar, qty- 02 nos. (6) panel meter for dc voltage current, 200v, 10a dual display. make- siemens, l&t or similar, qty-02 nos. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and replacement of spares for relay test bench at lgds of make: m/s advance instrumentation n control systems(aics) 1) supply and replacement of single phase variac in relay test bench of make aics- 01 no 2) supply and replacement of diode bridge assembly in relay test bench of make aics- 01 no [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of test lead-lcr-12. test lead with kelvin clip. make. gw instek , ac variac input 230v ac, output 0-300vac ac/10 amps. make dataera ev systems or vep2 , ac variac input 230v ac, output 0-300vac ac/15 amps. make dataera ev systems or vep2
Tender For corrigendum : tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for pfc and tri
Tender For procurement and installation of eee lab equipments - procurement and installation of eee lab equipments, dc series motor with starting and loading arrangement with electrical work bench motor rating: 5 hp , 220 v , 1500 rpm, loading arrangement : mechanical rope with aluminum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s workbench: with back side lock 1. 2 point starter 2. ammeter ( 0 - 30a) dc 3. voltmeter ( 0- 300v) dc 4. rheostat - 1 no., single phase transformer step dwon, single phase, 2kva , 230/115 v , 4a / 8a, 3 phase transformer step down three phase, 2kva, 440/220v., transformer oil bdv test kit single phase, 230v, output voltage 60kv with timer, acidity test kit single phase, ac 230v,50hz, astm d974, rating scale, ,color chart, required, test tunes & solutions, three phase auto transformer three phase variac, 415 / (0-470)v, 15a, linear variable differential transformer measurement trainer input voltage : 230 v ac / 50 hz lcd display, digital voltmeterlvdt stroke length : 25mm potentiometer includedoperating temperature :10 c to 50 c, dso bandwidth: 50 mhz channels: 2 (dual trace)sampling rate: 1 gsa/s time base & voltage controls: variable display: color lcdprobes: 2 nos supplied interface: usb
Tender For supply of mechanical engineering lab materials - mechanical engineering lab materials, serve motor drive kitinterface l293d motor driver ic with arduino to control direction of rotation of two dc motors), bldc motor kitbldc motor 1 nobldc motor drive -1noinbuilt volt and ammeter and rpm meterinbuilt power supplyinput 230v ac, lvdt trainer kit complete educational trainer for linear variable differential transformer (lvdt) displacement measurement. built-in ac excitation source and signal conditioning circuitry for lvdt operation. micrometer assembly for precise linear movement of the lvdt core. displacement range ~10 mm with clear front-panel adjustments for zero & calibration. digital display (typically 3 -digit) for direct readout of conditioned output/displacement values. test points and banana sockets for signal observation on external instruments. self-contained unit in a durable enclosure with labeled controls and educational layout. includes user manual and patch cords for experiments. operates on 230 v ac, 50 hz mains supply., multi-cylinder petrolphase : single phase load: mechanical load with ropenumber of cylinders : 4displacement : rope brakepower : 65hp,4000 rpm,1396 ccbrand material : mild steelengine type : 4 stroke self startfrequency : 15hzfuel consumption : petrolfuel tank capacity : 5 letermorh s test rig, tail stock assemblyheavy-duty lathe tailstock assembly for training; cast iron body with base, barrel (quill) ~50 75 mm stroke, hand wheel feed, dead centre mt2/mt3, set over screws for taper turning, spindle clamp, complete with all internal parts for dismantling and reassembly; suitable for 300 400 mm centre height training lathe., dc motorvoltage 220-440 v dcpower - 180 w speed - 200 rpm, hydraulic cylinderdouble acting hydraulic cylinder, bore 40 50 mm, stroke 200 300 mm, working pressure up to 100 160 bar, steel tube with honed bore, hard chromed piston rod, front & rear end caps, piston with seals and wear rings. supplied as standalone unit with suitable mounting for dismantling, inspection and reassembly., hydraulic opreated directional control valve (dcv)manually operated 3/2 or 4/2 way spool type hydraulic directional control valve, nominal size ng06 (cetop 3) or equivalent, rated pressure 210 bar, flow 20 40 lpm; valve body with hardened and ground spool, centering springs, ports p a b t clearly marked. supplied on small mounting plate for dismantling, inspection and assembly practice., bearing with shaft assemblyteaching unit with shaft 25 35 mm dia mounted in housing with deep groove ball bearings (6205 / 6206 class) at both ends; includes locking arrangements (circlips, lock nuts, covers). designed for repeated removal, cleaning, lubrication and refitting of bearings, with provision to mount on bench or test rig., coupling unit using driving and driven shaft plumber block bearing unit1. the plummer block housingmaterial: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing).sealing: felt seals or v-ring seals (to demonstrate lubrication retention).lubrication: provided with a grease nipple at the top center for manual lubrication practice.2. the bearingtype: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series).bore diameter: standard 25mm or 30 mm (ideal for lab scale).mounting: adapter sleeve mounting (h-series) to teach students how to lock a bearing onto a smooth shaft.3. shafting and couplingshaft material: ground carbon steel (en8 or en9) for high surface finish.coupling type: * flexible coupling: to demonstrate the bearings ability to handle slight misalignment.rigid flange coupling: to demonstrate traditional direct connection.driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven)., spring test machine load & displacement sensing load cel * capacity: 0 10 kno accuracy: 1% fs (better if 0.5% fs) displacement sensor * lvdt / digital encodero accur