Get complete information related to latest Vault Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vault Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vault Tenders.
Tender For corrigendum : supply of cold end gasket for the fm service area viewing window as per the sketch kaps-1&2-21322 1 , hot end outer gasket for fm service rea viewing window as per the sketch-kaps-1&2- 21322 -2 , hot end inner gasket for fm service rea viewing window as per the sketch-kaps-1&2-21322-3 , spacer for fm vault and fm service rea viewing window as per the sketch- kaps-1&2-21322-sketch-4
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For request for proposal (rfp) for selection of system integrator for supply, commissioning, testing, integration and operation and maintenance of aua kua solution with aadhaar data vault for the government of meghalaya
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; assistance in cobalt element replacement for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; coolant channel in-service inspection assistance in fueling machine vault for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; assistance in barcis erection activity in fueling machine vault for details refer boq; as per scope of work,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajasthan site unit-3 and 4; zig saw panels removal and installation, installation is to be done as per satisfaction and checking b the fhu section for detail..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rawatbhata rajas
Tender For auction sale of depot ferrous scrap - cond. & u/s bazaar scrap such as various types of filters, dust shield spring and including highly corroded nature of foot steps, berth frame, fs shutters, transfer trolley, trolley wheel, car body filter, showel w/wo handle, cot, vacuum cylinder, vacuum chamber, corroded/ dinged/ damaged wagon door, mortar pan, wire powrah, h s lamp, corroded drums of various capacity, zinc coated fs sheets, wagon floor sheet, g.i. sheet, guide spring, guide ring, foam ladder, small paint tins,saw blade, fire bucket, main switch stand, coach door, sliding door, battery boxes, battery box door, collapsible gate, thin spring of various shapes, sorts and sizes in corroded condition, highly corroded nature items (cut barrels, corroded paint drums & barrels), air filter,highly corroded nature items (paint drums), empty dpt can (bazaar), punches plate/ sheet/ screen, corroded shear cutups, ms angle,half cut barrels, traction motor filter (bazaar), channel, cut rails, roof light/tube light fitting, fl housing regulator box, carriage fan body cover/end shield/ guard/ blade, pedestal fan guard, air brake pipes, corr. barrels/paint drums, silent block, anchor block, wires, chains, boxes, hoop iron, lamps, wall protector, trough sheets, air filter, clips, panels, gi pipes with/without valves, ci covers, corroded/ damaged/ dinged condition coach/wagon cutup parts, sheets, equalizing stay, brake anchor, commode chutes, pins, rivets, bolts, nuts, small iron pieces, wire rope/safety rope with/without aluminum sling and all other ms/ci/fab items of highly corroded nature and all the above items are of sorts and sizes in full/cut/broken/damaged and with/without minor nfs attachments including loose bits as is where is condition. pl.no. 98090800. custodian: cdms-rsf-gsd-per. note: (1) cutting not permitted. (2) during delivery, if any major nfs items found, the same needs to be handed over to custodian. location: 1)14th pathway lhs adjacent to bin 1, 2)14th pathway lhs bin 1, 3)14th pathway rhs wall end.