Web Analytics Made Easy - StatCounter

Vcb Panel Board Tenders

Get complete information related to latest Vcb Panel Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vcb Panel Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vcb Panel Board Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45592259 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For rate contract for supply, installation, testing and commissioning of various materials required for maintenance of 33/11 kv receiving stations for smooth running of power supply from receiving stations under the jurisdiction of std pulwama for the fy 2026 27 - installation,testing and commissioning of 11 kv vcb panel board 12 kv, 1250a, 25 ka, (incommer), installation,testing and commissioning of 11 kv vcb panel board 12 kv, 1250a, 25 ka, (outgoing, installation,testing and commissioning of 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type), dismantalling of old, 11kv vcb panel complete, 33kv c&r panel complete, installation,testing and commissioning of of 33 kv c&r panel, supply, installation,testing and commissioning of fresh 11kv c.t confirming to iec 60044-1-2000 standards suitable for following 11kv vcb with ratio 800-400/5-5-5a, 600-300, 400-200, 100-50 of make like alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out 11 kv c.t, installation,testing and commissioning of fresh 11kv c.t by way of replacement of damaged/burnt out 11 kv c.t of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11kv vcb panels), supply,installation,testing and commissioning of 11kv p.t confirming to iec 60044-1-2000 standards (for 11kv vcb panels) by way of replacement of damaged/burnt out 11 kv p.t, installation,testing and commissioning of fresh 11kv p.t by way of replacement of damaged/burnt out 11 kv p.t of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11kv vcb panel), supply,installation,testing and commissioning of fresh male contact (set of 06 pcs) of following 11kv vcb of make alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, supply,installation,testing and commissioning of fresh female contact (set of 06 pcs) of following 11kv vcb of make alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, installation,testing and commissioning of fresh male/female contactof following 11kv vcb by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, supply,installation,testing and commissioning of 11kv vacuum interruptor by way of replacement of damaged/burnt out 11kv vacuum interruptor of same composition,type,make as already installed in 11kv vcb panel (1250amps) of following make, alsthom make, easun reyroll make, stelmec, vijay make, sudhir make, electric field, crompton greeves, allind, abb make, pascal make, hartek make, supply, installation,testing and commissioning of 33 kv vacuum interruptor for 33kv vcb panel by way of replacement of damaged/burnt out of following make, alsthom make, crompton greeves, abb make, megavwin make, fixing of fresh 33kv / 11kv vacuum interruptor by way of replacement of damaged/burnt out 11kv vacuum interruptor of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department), supply, installation,testing and commissioning of numerical/digital relay (a.c &d.c),type,make and class already installed in panel (3oc+1ef).all relays shall conform to the requirements of is:3231/iec-60255 and iec-61850 of operating voltage 30-36volts by way of replacement of damaged/burnt out of make, asida adr241b make, cg make, abb 615 make, abb rej601 make, fixing , testing and commissioning of numerical/digital relay of types, supply,installation,testing and commissioning of of panel insulator (supporting insulator for bu

State Government

CTN :45481921 Due date: 02 Jul, 202602 Jul, 2026 23.61 Lacs
Tender For supply, installation, testing and commissioning of 11kv vcb panel board (12kv 1250a 25ka with over current fault earth fault relays iec61850 mimic diagram voltmeter ammeter annunciation windows with annunciation relays 3 phase trivector meter 5amps dlms complaint with rs485 peernia rs

corporations/Associations/Others

CTN :45205777 Due date: 30 May, 202630 May, 2026 NA
Tender For etender cum auction for sale of non moving and obsolete items ferrous and non ferrous scraps etc in available at central store gcc trichy and substores virudhachalam - lot - 1 ( items -2) 1.ct 110 kv 150-75-50/1a (metering ct ) 0.2 s accurasy -15 nos. 2.copper cable scrap (thennur yard ) - 9354 kg the details are given in the specifications., lot - 2. ( items -2 ) 1. miscellaneous iron scrap-16432kg 2.gi scrap ( thennur yard)-6276 kg the details are given in the specifications., lot-3 (items-1) 1.miscellaneous iron scrap (thennur yard)-12352 kg the details are given in the specifications., lot-4 (items-7) 1. miscellaneous iron scrap (collectorate yard) -8230 kg 2.bolt and nut gi 70 x 20 mm-500 kg 3.bolt and nut gi 40 x 20 mm-500 kg 4.bolt and nut gi 45 x 20 mm - 550 kg 5.bolt and nut gi 65 x 20 mm-459 kg 6.bolt and nut gi 65 x 18 mm-100 kg 7.bolt and nut gi 60 x 20 mm-300 kg the details are given in the specifications., lot-5 (items-1) 1. gi scrap (collectorate yard)-18666 kg the details are given in the specifications., lot-6 (items-1) 1. acsr scrap (thennur yard)-30937 kg the details are given in the specifications., lot-7 (items-1) 1. acsr scrap (thennur yard)-30110 kg the details are given in the specifications., lot-8 (items-1) 1.gi wire scrap (thennur yard)-13300 kg the details are given in the specifications., lot-9 (items-1 ) 1. gi / ms tower angle scrap (thennur yard)-53023 kg the details are given in the specifications., lot- 10 (items- 1) 1.gi / ms tower angle scrap (collectorate yard)-50000kg the details are given in the specifications., lot-11 (items-1 ) 1. gi / ms tower angle scrap (collectorate yard) - 53439 kg the details are given in the specifications., lot-12 (items-1 ) 1.empty steel drum 3 to 6 dia (thennur-82 & collectorate-19) -101 no. the details are given in the specifications., lot-13 (items-2) 1.empty barrel 40/45 gl capacity leaky- 194 no 2.empty barrel 40/45 gl capacity sh- 173 no. the details are given in the specifications., lot-14 (items-17) 1. condemned gas cylinder various size-29 no. 2.condemned fire extingushers various size-13 no. 3.alu . incl .aac cutbits scrap-1993 kg 4.scrap alu lug cable -775 kg 5. scrap gi with porcelin-659 kg 6. condemned dc panel scrap-5 no 7. machinary parts scrap- 1588 kg 8.scrap teak wood-6 kg 9.scrap meters/meter parts-33 kg 10. scrap aluminium with insulation-535 kg 11.cond petrol chain saw machine 22"- 1 no. 12. cond window type a/c 1.5 ton-4 no 13. cond battery charger-1 no 14. cond walkie talkie (set of 2 nos)-1 no. 15.cond split ac various capacity-6 no. 16.cond binoculars-1 no. 17. cond gas leakage detector-1 no. the details are given in the specifications., lot-15 (items-1 ) condemned lorry 10 ton capacity reg no tn 45- k 6734, ashoke leyland with stepney, jacky with lever & wheel spanner available at 230 kv auto ss campus perambalur - 1 no. the details are given in the specifications., lot-16 (items-4) 1. cond mini bus 1) reg.no:tn 49 f 3640, make:eicher mlv with stepney, jacky & lever.2.reg.no:tn 45 f 3689, make: ashoke leyland with stepney, jacky & lever. 3.reg.no:tn 45 k 5956, make: eicher lmv with stepney, jacky & lever. 2. cond van/ reg.no: tn 45 f 7571 make: bajaj tempo ltd., with stepney,jacky & lever available at 110 kv grid ss store campus.the details are given in the specifications., lot-17 (items-2) condemned lorry 10 ton capacity: 1.reg no tn 45 - p 8575, ashoke leyland with stepney, jacky with lever & wheel spanner avalable at 110 kv grid ss campus, m.c.road, thanjavur. 2.reg no tn 45/ q 6201, ashoke leylandwith out stepney, jacky with lever & wheel spanner avalable at 110 kv grid ss campus, m.c.road, thanjavur. the details are given in the specifications., lot-18 (item-2 nos.) condemned lorry 10 ton capacity: 1. reg no tn 45/ m 9769, ashoke leyland with stepney, jacky with lever & wheel spanner available at 110 kv grid ss campus/trichy store. 2.reg no tn 45/ f 8341, ashoke leyland with stepney, jacky with l

corporations/Associations/Others

CTN :45294072 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For etender cum auction for sale of non moving and obsolete items ferrous and non ferrous scraps etc in available at central store gcc trichy and substores virudhachalam - lot - 1 ( items -2) 1.ct 110 kv 150-75-50/1a (metering ct ) 0.2 s accurasy -15 nos. 2.copper cable scrap (thennur yard ) - 9354 kg the details are given in the specifications., lot - 2. ( items -2 ) 1. miscellaneous iron scrap-16432kg 2.gi scrap ( thennur yard)-6276 kg the details are given in the specifications., lot-3 (items-1) 1.miscellaneous iron scrap (thennur yard)-12352 kg the details are given in the specifications., lot-4 (items-7) 1. miscellaneous iron scrap (collectorate yard) -8230 kg 2.bolt and nut gi 70 x 20 mm-500 kg 3.bolt and nut gi 40 x 20 mm-500 kg 4.bolt and nut gi 45 x 20 mm - 550 kg 5.bolt and nut gi 65 x 20 mm-459 kg 6.bolt and nut gi 65 x 18 mm-100 kg 7.bolt and nut gi 60 x 20 mm-300 kg the details are given in the specifications., lot-5 (items-1) 1. gi scrap (collectorate yard)-18666 kg the details are given in the specifications., lot-6 (items-1) 1. acsr scrap (thennur yard)-30937 kg the details are given in the specifications., lot-7 (items-1) 1. acsr scrap (thennur yard)-30110 kg the details are given in the specifications., lot-8 (items-1) 1.gi wire scrap (thennur yard)-13300 kg the details are given in the specifications., lot-9 (items-1 ) 1. gi / ms tower angle scrap (thennur yard)-53023 kg the details are given in the specifications., lot- 10 (items- 1) 1.gi / ms tower angle scrap (collectorate yard)-50000kg the details are given in the specifications., lot-11 (items-1 ) 1. gi / ms tower angle scrap (collectorate yard) - 53439 kg the details are given in the specifications., lot-12 (items-1 ) 1.empty steel drum 3 to 6 dia (thennur-82 & collectorate-19) -101 no. the details are given in the specifications., lot-13 (items-2) 1.empty barrel 40/45 gl capacity leaky- 194 no 2.empty barrel 40/45 gl capacity sh- 173 no. the details are given in the specifications., lot-14 (items-17) 1. condemned gas cylinder various size-29 no. 2.condemned fire extingushers various size-13 no. 3.alu . incl .aac cutbits scrap-1993 kg 4.scrap alu lug cable -775 kg 5. scrap gi with porcelin-659 kg 6. condemned dc panel scrap-5 no 7. machinary parts scrap- 1588 kg 8.scrap teak wood-6 kg 9.scrap meters/meter parts-33 kg 10. scrap aluminium with insulation-535 kg 11.cond petrol chain saw machine 22"- 1 no. 12. cond window type a/c 1.5 ton-4 no 13. cond battery charger-1 no 14. cond walkie talkie (set of 2 nos)-1 no. 15.cond split ac various capacity-6 no. 16.cond binoculars-1 no. 17. cond gas leakage detector-1 no. the details are given in the specifications., lot-15 (items-1 ) condemned lorry 10 ton capacity reg no tn 45- k 6734, ashoke leyland with stepney, jacky with lever & wheel spanner available at 230 kv auto ss campus perambalur - 1 no. the details are given in the specifications., lot-16 (items-4) 1. cond mini bus 1) reg.no:tn 49 f 3640, make:eicher mlv with stepney, jacky & lever.2.reg.no:tn 45 f 3689, make: ashoke leyland with stepney, jacky & lever. 3.reg.no:tn 45 k 5956, make: eicher lmv with stepney, jacky & lever. 2. cond van/ reg.no: tn 45 f 7571 make: bajaj tempo ltd., with stepney,jacky & lever available at 110 kv grid ss store campus.the details are given in the specifications., lot-17 (items-2) condemned lorry 10 ton capacity: 1.reg no tn 45 - p 8575, ashoke leyland with stepney, jacky with lever & wheel spanner avalable at 110 kv grid ss campus, m.c.road, thanjavur. 2.reg no tn 45/ q 6201, ashoke leylandwith out stepney, jacky with lever & wheel spanner avalable at 110 kv grid ss campus, m.c.road, thanjavur. the details are given in the specifications., lot-18 (item-2 nos.) condemned lorry 10 ton capacity: 1. reg no tn 45/ m 9769, ashoke leyland with stepney, jacky with lever & wheel spanner available at 110 kv grid ss campus/trichy store. 2.reg no tn 45/ f 8341, ashoke leyland with stepney, jacky with l

CTN :45083875 Due date: 26 May, 202626 May, 2026 35.00 Lacs
Tender For stage contract for supply of key materials required for maintenance of 33/11kv receiving stations along with their lines under the jurisdiction of std bijbehara during the year 2026-27 - electrical store/workshop items/: as per is standards, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (incommer) as per technical specifications of rec std, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (outgoing) as per technical specifications of rec std, 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type) as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with out differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv isolator with earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv isolator without earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv outdoor, oil cooled, live tank, single phase , 3 core ct set as per isi specification with accuracy class sp 10 for protection,0.5 for metering & ps for differential with ratio 800-400/5-5-5a ,600-300/5-5-5a , 500-250/5-5-5a, 400-200/5-5-5a (per set of 3 pieces), 33 kv outdoor, oil cooled, copper wound , single phase , pt set with rated primary voltage 33000/ 3 & rated secondary voltage 110/ 3 as per isi specification with accuracy class 0.5 (per set of 3 pieces)., 33 kv lightening arrestors (30 kv, 10ka, station class, zno, porcelain/polymer) gap less(per set of 3 pieces)., 33 kv post insulator (polymer/porcelain 36kv, 170kv impulse), galvanised steel structures(6" g i pipe with top,base & grouting bolts) as per rec, 11kv (e) grade armoured ,almunium,400 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 300 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium,240 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 185 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 120 sq mm,3-core,xlpe power cable, (std make), 2.5 sqmm 2 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 4 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 6 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 8 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), l t cable 3 1/2 16 sq.mm core armored , al conductor sheathed pvc insulated (std make), 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m or raychem make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 400sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 300sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 240sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 185sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 120sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for

corporations/Associations/Others

CTN :45087573 Due date: 14 May, 202614 May, 2026 29.92 Lacs
Tender For repairing servicing overhauling for ssg make vcb panel board and megawin borad including cleaning coating with anti oxidant treatment on all the insulating part at ess state guest house in nehru park zon
 Loading, Please wait...

Connect us via What's Up