Web Analytics Made Easy - StatCounter

Vcb Panel Repair Tenders

Get complete information related to latest Vcb Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vcb Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vcb Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45048307 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese

Central Government/Public Sector

CTN :45086045 Due date: 26 May, 202626 May, 2026 NA
Tender For supply of ht switchboard panel (nflp) / vcb panel, 6 panel, 6.6kv, 630a , ht switchboard panel (nflp) / vcb panel, 5 panel, 6.6kv, 630a , ht switchboard panel (nflp) / vcb panel, 14 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 14 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 13 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 13 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 10 panel, 3.3kv, 800a , ht switchboard panel (nflp) / vcb panel, 9 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 8 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 7 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 6 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 5 panel, 3.3kv, 630a , ht switchboard panel/ vcb panel comprising of single vcb (single vcb in nflp enclosure) , 3.3kv, 630a , ht switchboard panel/ vcb panel comprising of single vcb (single vcb in nflp enclosure) , 3.3kv, 400a

State Government

CTN :43634844 Due date: 16 Apr, 202616 Apr, 2026 3.43 Crore
Tender For corrigendum : supply, installation and commissioning of 11 kv vcb switchboard of specified ratings at the power house of rammam hydel project stage-ii, wbsedcl including dismantling of existing siemens 8bk20 panel and shifting of the same to store - supply, installation and commissioning of 11 kv vcb switchboard of rating and other details specified within the tender document at the power house of rammam hydel project stage-ii, wbsedcl including dismantling of existing siemens 8bk20 panel and shifting of the same to store
 Loading, Please wait...

Connect us via What's Up