Tender For supply of contactor (with diode) conforming to iec : 60497 for ventilationfan motor in lhb coaches of current rating 9 a, ac3 voltage rating 415 volts ac; main pole 3 no; auxiliary contact 1 nc, control voltage 77 to 143 volt dc with surge suppressor of type / make: tal9-30-01-62+rt5/150 of abb or lc1-d09fd of schneider or 3rt2016-1bf42 + 3rt2916-1jl00 of siemens as per rdso specificationno. rdso/pe/spec/ac/0184-2015 rev. 0. offers from oem or their authorized dealers will only accepted. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing & commissioning of 08 ft dia hvls gearless fan similar to mg fans model no. mg-pmsm-086 with all associated accessories like: hanging frame (upper & lower) motor with mounting frame blade mounting hub set fan blades guy wire control panel with vfd mcb hardware set 4 ? 2.5 sqmm copper cable (max. 30 meters per fan) as per specification . [ warranty period: 30 months after the date of delivery ] ]
Tender For maint repair replacement of point wiring replacement of led fittings repair maint of electric geysers building security lights exhaust fan control cables and connected items under ge 859 ews
Tender For corrigendum : supply of ultrasonic level transmitter , pressure gauge , load cell , magnetic flow transmitter , flow control valve , limit switch , pressure gaguge , pressure transmitter , zero speed switch , flow transmitter , pull cord switch , pressure switch 7 bar , pressure gauge , radar level transmitter , pneumatic operated on or off ball valves , temperature gauge , temperature switch , pressure indicating transmitter , level switch , solenoid valve to lift rack up and lower , pressure switch , limit switch , bed mass transmitter , bed level transmitter , rake level transmitter , moulded case circuit breaker , rotary drive kit , motor protection circuit breaker , power contactor , semiconductor fuse , vfd , miniature circuit breaker , control transformer , potential transformer , ups , led indicating lamp for r phase red , led indicating lamp for y phase yellow , led indicating lamp for b phase blue , led indicating lamp for feeder on red rating 230vac , led indicating lamp for feeder off green rating 230vac , led indicating lamp for feeder trip amber rating 230vac , opaque actuator with holder push button for feeder start green , no block , opaqueactuatorwith holder push button for feeder stop red , nc block , opaque actuator with holder push button for dosing pump speed , opaqueactuatorwith holder push button for alarm reset black , opaque actuator with holder push button for alarni acknowledge yellow , mushroom actuator , 1nc 1 nc contacts , 1 way plastic control stations with yellow cover , 2 pole 2 way selector switch for feeder local , auxiliary relay , socket , auxiliary plug , signal isolator , panel top indicator , power supply module , plc , pneumatic operated on off ball valves , di or do card , ai or ao card , di card , hmi , ethernet switch , industrial ethernet cable 2x2 , rj 45 connetor , door mounted limit switch , tube light , enclosure heater , thermostat , utility socket , 6 inch fan and filter , vacuum gauge 3 by 8 inch bsp , pressure gauge 3 by 8 inch bsp //bid details 2 / 74
Tender For supply of vdc mv o p 4 20ma , digital energy meter connection 3 phase 3 wire ct ratio 10000 5 amp pt ratio 1575 kv 110 v50 hz acc class 2s make seccure apex 150 , transformer pt 415v 110v , portable digital megger test voltage , thermal o l relay mn2 4 2 to 7 5a , thermal o l relay 2 5 4 amp , dc clamp meter dc current 0 1a to 200a ac current 0 1a to 200a dc ac voltage 0 1v to 600v continuity data hold fa make motwane , control transformer t 1 input voltage 0 440v output s1 0 110 220 and s2 0 110 220 as per sample rating 50va , control transformer t 2 input voltage 0 440v output 0 18 24 as per sample rating 50va , heating element of esp hopper 0 5kw , transformer oil drum 210 lit , dehy breather for hvr transformer of esp , buchholz relay type gor 1 with alarm trip contact 1no plus 1nc , magnetic oil gauge with one tripping contact , prismatic oil level indicator size 150mmx60mm , glove valve size 25mm brass both side flange end , crc contact cleaner 300 ml cane , neoprene rubber sheet 1x2mtr thick 10mm , aluminium lugs 70sq mm als 226 e bolt hole 13mm make dowells , aluminium lugs 185 sq mm als 235 e bolt hole 17mm make dowells , aluminium lugs 120sq mm als 230 e bolt hole 13mm make dowells , aluminium ferrule 120sq mm make dowells , aluminium ferrule 150 sq mm make dowells , copper ferrule size 185 sq mm make dowells , copper ferrule size 120 sq mm make dowells , push button on off with element , hrc fuse3na 7805 orc 16 a make siemens , hrc fuse3na 7820 orc 32 a make siemens , mccbn 16r 150a 3p , ns type fuse 32 amp , ns type fuse6 amp , ns type fuse 25 amp , on delay timer 0 5 sec to 100 hours 24 240v ac dc , local remote switch 25a 440v brand kaycee siemens havell l t , voltmeter sel switchmodel srp1373way off , din type fuse rating 100 a , din type fuse rating 125 a , hrc fuse t a 32 rated for 32 amp code no sfb 8116032 , pin type insulator 0 4kv , petroleum jelly for battery , din type fuse hrc size 3 current rating 500 amp , rectifier fuses 150 amps semiconductor type , led indication lamp red yellow blue green 220v ac dc , dd module 236 amp 1000piv , dd module 260 amp 1600piv , dd module 70 amp 1000piv , mccb 150a 3 pole , motor cooling fan with cover for 2 2 kw gt cooling fan motor , control fuse ns type 2amp , control fuse ns type 4 amp , control fuse ns type 6 amp , din type hrc fuse 25a 415v ac size 00 , din type hrc fuse 32a 415v ac size 00 , din type hrc fuse 63a 415v ac size 00 , analogue ac voltmeter range 0 500v , analogue ac voltmeter range 0 500v ptr 415 110 v , analogue ac ammeter range 0 50 amp ctr 50 , dc voltmeter moving iron jewel bearing range accuracy , ammeter range 0 15amp ctr 15 1 , moving iron analog ac ampere meter ct ratio 400 5a d , d c ammeter moving coil range , ac ammeter range 0 25amp , aux contactor 2no plus2nc coil voltage 24v ac , aux contactor 3no plus1nc coil voltage 24v ac , switch disconnector fuse unit 2pole current carrying capacity 315 amp max operating voltage 600 v 50hz for one to one replacement , power contactor 3pole current carrying capacity 315amp max operating voltage 600v coil voltage 220 250vac 50hz dc for one to one replacement , local remote selector switch 10a model type 2s26b or equivalent for one to one replacement , ammeter rotary switch 12a r y b off 4 position 90 degree , voltmeter selector switch 12a ry yb br off , local remote selector switch 3 pole2 way without off 16 amp , tnc rotary switch 25amp spring return to neutral model type , switch //bid details 2 / 59 fuse unit 63a 3p , switch fuse unit 125a , thermal overload relay
Tender For invitation quotation for data rates of electrical items. - releasing and refixing of 30 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of 12/16/20 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of tubular/ octagonal/conical poles of height 5 mtr to 10 mtr height. including labour, crane and transportation charges. (excluding foundation work), amc chagres for 180 to 200 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials included, amc chagres for 125 to 160 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials inclueded, amc chagres for 63 to 100 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. and other all material included, hire charges for servicing & maintaining of 3 ton cassette type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors.inspect fan for bent blade and correct as necessary, hire charges for servicing maintaining of 2 ton split type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors. inspect fan for bent blade and correct as necessary, servicing & maintaining of 10 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 5 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 3 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units, remote control and monitoring of individual streetlight using lora communication technology a lora-based street lighting system utilizes lora (long range) communication technology to create a low-power, wide-area network (lpwan) for the remote control and monitoring of streetlights. each streetlight node is equipped with a microcontroller, a lora transceiver, and sensors such as ldrs or pir for ambient light detection and motion sensing., supply and installation of electronic timer for streetlights consisting of microcontroller based electronic timer with rtc, 2x16 lcd wit back light, 5 tactile keys, supplying and installation of intelligent three phase centralised control and monitoring system for street lights, the ccms unit should be capable of switching on & off the lights of a particular switching or networked switching points from central control system automatically