Get complete information related to latest Ventilation Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ventilation Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ventilation Filter Tenders.
Tender For supply of set of filters for 3-phase underslung memu traction motor type tme-49-35-4. a) part no-sptsa017332r0001.- 01 no. b) part no-sptsa017333r0001. -01 no. [ warranty period: 30 months after the date of delivery ] ]
Tender For auction sale of depot ferrous scrap - ubl/gsd/c-0031/air filter /26/c [pl no.98412164] condemned and un- serviceable air filter scrap consisting of air filters, lhb fresh air filters, return air filters, inner air flitters and outer air filters vehicle air filter, forklift fuel/lube oil filters, demu bypass oil/lube oil filters ,compressor air/oil filters, dynacell filter, filter parts, air filter of 1400hp demu dpc cummins, outer /inner air filters, catepiller outer/inner air filters and other similar scrap, in different condition with or without ms/ss/aluminum/cloth/paper attachments . available under the custody of cdms/rs ward/gsd/ubl. note: purchaser has to physically inspect the lot before bidding.location: road no -02 gsd/ubl bin no-block: c-031. remarks-. delivery should start from one end. no pick and choose allowed.
Tender For supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: pre filter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: pre filter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For corrigendum : supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: pre filter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: pre filter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep