Tender For supply of 50 watt fm transmitter , internet radio for audio processing , 2 way dipole anteena , rf cable , 19 inch audio video equipment enclosure , 100w dummy load , self supported tower 30 mtr with lightening arrester and earthing , 100 watt active monitor speaker , 12 channel analog audio mixer , condenser microphone , desktop editing workstation for audio video processing , table top mic stand , suspension type mic stand , studio headphone , on air logger software , dynamic cardioid microphone , field recorder , 6 ch audio distribution unit , 6 ch headphone distribution unit , telephone hybrid , power conditioning unit 3 kva with battery set , backup power supply unit 10 kva with canopy , 2 into 2 warm studio light , electric work earthing and wiring complete studio , wall acoustic work , sound proof door , false ceiling treatment , sound proof flooring mat , furniture for production table to house the console outside production studio room comma onair studio table comma transmission room table comma reception table , installation material and freight charge bracket on cable comma connector for audio wiring bracket off , warning light bracket on recording bracket off , warning light bracket on on air bracket off , initial application charge , sacfa clearance charge , spectrum charges , bank guarantee charge , stamp paper charge , notary charges , public performance license for bundle music air time , station manager , technician , attender , radio jockey two member team , electricity bill , refreshment charges , fol charges , air internet , telephone and mobile charges ) /bid number : gem/2025/b/6380130 * /dated: 04-07-2025 & & / bid document 1 / 40
Tender For supply of community radio station at dirang - 50 w fm transmitter , two bay 2 dipole , rf cable rf co axial cable 50 mtr with n connector , 19inch ru eqpt rack for transmitter , 100w dummy load with matching transformer , manual change over panel with three patch card for switching between main and standby tx , supply installation testing and commissioning of 30mtr self supported tower on ground with foundation erection galvanizing earthing lightning arrestor aviation light , 10 band fm audio broadcast processor internet streamer with iphone android application , monitor speaker 50w , 12 ch analog mixer , 16 ch analog mixer , rj condenser microphone , desktop audio work station , 2 channel usb sound card , table top stand , flexible microphone stand , headphone , playout software with logger , dynamic cardioid microphone , hand held recorder , audio distribution amplifier 1 stereo input and 6 stereo output , headphone distribution amplifier 1 stereo input and 6 stereo output , studio on air light , misc installation material like audio cable connector etc for the installation of above mentioned eqpts , installation and commissioning work to make the crs fully functional include , wall acoustic work 10x12x2 , brick wall partition work for studio room , brick wall partition work for recording room , wooden sound proof door , observation window , production table to house the console , on air table , transmitter room table , electrical work , earthing , heat radiator , license crs , content creation ppl license , station manager , technician , radio jockey member one , radio jockey member two
Tender For supply of provn of non tech equipment for crs budgam - wall acoustic work incl outer shelter , wooden sound proof door , fall celling treatment , observation window , flooring carpet , wooden partitions , table 3 x 5 , 3kva online ups , running and maint to incl fol electricity bill sty tea minor repair and adm expdr , initial application charges , sacfa clearance charges , bank guarantee charges , stamp paper charges , spectrum charges 11 months wef initial agreement , notary charges , public performance license for bundle music air time , water dispenser , small locker , induction cooktop , fry pan , sauce pan , borosil glass 6 pcs set , cup 6 pcs set , tray , rotating chair , file rack , white board , table glass , printer , pen stand , digital wall clock , banner for crs , dust absorber machine vacuum clearner , salary of 02 months
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For shifting and overhauling of 5 kva single phase sound proof diesel generator from old criminal court compound to new criminal court building including allied e.i work at diamond harbour sub-division, south 24 praganas, pwd