Get complete information related to latest Ventilation System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ventilation System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ventilation System Tenders.
Tender For supply, termination installation, testing and commissioning of ventilationsystem in paint shop of lower parel workshop along with complete installation of industrial air blower with movable trolley, operating voltage 190v ac to 380 v ac, 50 hz, single/three phase supply, maximum power consumption shall be less than 600 watt, maximum speed of 400 rpm, air flow of 700 meter cube per minute, weight shallbe less than 60 kg and noise shall be less than 50db. size of blower shall not be more than 1500 mm diameter confirming to is 6272-1987 or latest all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt 1) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. materiat shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt. agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of ug bkr fsc : - suppy and construction of ug bunker fsc , cement of 43 grade opc , river sand , stone aggregate 40 mm , stone boulders for hard core , placing of ug bunker , video camera based entry system , hot and cool air conditioner , tunnel ventilationsystem , high efficiency heat exchanger , fire alarm system , hepa filters , activated carbon filters , pressurized oxygen tank , high efficiency solar panels , supply comma installing comma testing and commissioning , multi angle digital camera system , provision of duct for two way , installation of layered led lighting , highly efficient foldable table , modular storage racks , cool glove box , lockable compartments , gi plate 600mm x 600mm x 6mm , gi wire 4 mm , cast iron cover , charcoal , common sal , gi pipe 20 mm , nuts and bolts , lightening conductor , entrance canopy
Tender For supply of new fitting of air filter hose , overhauling and calibration of all injectors assy , complete servicing and cleaning of exhaust gas recirculation sys , ecm programming and scanning , complete servicing and cleaning of ac system
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49