Web Analytics Made Easy - StatCounter

Vesda System Tenders

Get complete information related to latest Vesda System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vesda System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vesda System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45261861 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of apollo make addressable type xp-95 optical detector as per attached specifications , apollo make addressable soteria multi-sensor detector as per attached spec , apollo make addressable xp-95 heat detector as per attached spec , apollo make addressable xp-95 manual call point as per attached spec , apollo make addressable xp-95 intrinsically safe optical detector as per attached spec , apollo make series 65 conventional optical smoke detector as per attached spec

CTN :45281871 Due date: 28 May, 202628 May, 2026 27.87 Lacs
Tender For moei, fans, 125 kva dg set, afas, wld system & vesda system, cctv, anti-rodent system, pa system, vrf system, cassette and split acs ups system at data centre and map section at census department, kendriya sadan, hyderabad for the year 2026-27.subwork/packages:moei, fans, 125 kva dg set, afas, wld system & vesda system, cctv, anti-rodent system, pa system, vrf system, cassette and split acs, ups system, at data centre and map section at census department, kendriya sadan, hyderabad for the year 2026-27.

CTN :45283647 Due date: 27 May, 202627 May, 2026 NA
Tender For supply of set of item require for lever locking arrangement for isolating cock of brake valve of vesda system as per drg. no. mi008044 alt. nil for fsds system. [ warranty period: 30 months after the date of delivery ] ]

CTN :45238057 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For tender for supply of lamp-asembly r/y/g/w , ups 2.4 kw spare-12 v 60 ah battery , terminal block 50/37 pin f/m , terminal block 50/37 pin f/m , fan , diode , 40.9v25.3a , vme fire detection interface(vfdi-4)cca , lamp-green , bilge liquid level switch , lamp-red , fuses fast-acting-3a , fuses fast-acting-5a , power supply ac/dc to ac , 115vav , 60hz , addressable uv detector , ir sensitive 0.1 lux camera , continuous level transduder(0-2m)is , liquid level switch(side mounted) , pressure transducer 0-5 bar , pressure transducer 0-10 bar , rugged rackmount console processor p4cpu , panel meter , anlog , 0-1000c , addressable dual ir flame detector , addressable interface module , circuit breaker din mount 20a , relay module 24vac/dcinput , 1spdt

Central Government/Public Sector

CTN :45194614 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of lever locking arrangement for isolating cock of brake valve of vesda system as per drg no mi008044 [ warranty period: 30 months after the date of delivery ] ]

CTN :44099758 Due date: 14 May, 202614 May, 2026 NA
Tender For bid to ras bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

Central Government/Public Sector

CTN :45121358 Due date: 21 May, 202621 May, 2026 NA
Tender For supply of analogue addressable multi sensor detector with multiple sensitivity (adjustable at site) levelse.g. smoke, heat, rate of rise heat etc, programmable for timed automatic sensitivity selection with base, and other accessories as required.as per rdso specification no. rdso/spn/217/2021 ver 3.0 or latest. [ warranty period: 30 months after the date of delivery ]

CTN :45072255 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges

Central Government And Public Sector

CTN :45064376 Due date: 23 May, 202623 May, 2026 8.18 Lacs
Tender For supply of addressable type fire alarm system at in north paravur : : - sitc of addressable main fire alarm panel , sitc of repeater panel , sitc of addressable photo thermal detector , sitc of addressable manual call point , sitc of addressable horn cum strobe , sitc of fault isolator , sitc of addressable fire control module , sitc of response indicator , supply and laying of 2x1.5 sqmm fire alarm armoured cable , sitc of mcp signage , sitc of relay module
 Loading, Please wait...

Connect us via What's Up