Get complete information related to latest Vhf Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vhf Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vhf Repair Tenders.
Tender For supply of sitc of network switch , sitc of switch rack , sitc of network controller , sitc of access points , sitc of rf device sender and receiver , sitc of rf device iron case , sitc of 4mp cctv cameras , sitc of 64 ch nvr , sitc of 3 kva online ups , sitc of network points io box , sitc of cables , sitc condute pipes , sitc of miscellaneous accessories
Tender For corrigendum : to award a rate contract for supply of isi marked, dlms compliant, lt static single phase and three phase smart meters along with rf network interface card (nic) and box
Tender For corrigendum : supply of vhf sets with accessories for cisf d d -portable digital radio set, , vhf repeater with high gain antenna , vhf base station radio sets , 5by8 3 db gain omindirectional antenna , rf coaxial cable with connectors 30mtr , 12vdc power supply unit 10amps batt , six slot charger for dmr handheld radios , network switch 24 port , liasoning charges , itc and programming of vhf system
Tender For supply, installation, testing and commissioning of dcus/gateways/ allocation of sim network service provider and the arrangement of sim cards to enable reliable medium for two-way communication between smart meter & amp:, hes (head end system) over rf mesh network/cellular network. 1. the dcu/gateway shall be compatible with the smart meters mentioned above. rf mesh network should use 865-867 mhz frequency band. 2. the data acquisition (push/pull) frequency shall be configurable 15 min, 30 min or 60 minutes. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. 3. it shall have provision for the cellular, wifi and ethernet communication for the backhaul tohes. 4. sufficient number of gateways shall be installed in such a way that all the meters are covered in the network efficiently. 5. it shall be capable to handle data of minimum 500 nos. of any type of smart meter (1ph/3ph). it shall be able to communicate with the nearest meters at a distance of at least 300 m, depending on topographical features. 6. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. 7. rfmesh shall support at least 15 no. of hops. 8. the equipment shall be weather-proof and dust-proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. 9. it shall have passed the following emc tests from reputed lab: conducted emission, electrostatic discharge (esd), radiated immunity, electrical fast transient (eft) - burst, surge, rf conducted disturbances. 10. rf mesh network shall be established to meet the slas as mentioned in tender document. 11. replacement warranty period shall be 66 (sixty-six) months from the date of supply or 60 (sixty) months from the date of commissioning, whichever is earlier. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : maintenance contract of computers printers ethernet switches and other peripherals supplied under lt billing project best phase i installed in various sections sub divisions division stores and mrt offices and maintenance of rf network
Tender For corrigendum : selection of bidder for design supply installation testing commissioning and maintenance of rf based network infrastructure in mauganj maihar pandhurna
Tender For supply, installation, testing and commissioning of telecom material (cctv surveillance system) in connection with ratlam division - upgradation and replacement of telecom passenger amenities and various facilities at various stations (simhastha 2028). - upgradation and replacement of telecom passenger amenities at variousstations (simhastha 2028). (project id:-15.05.53.25.3.54.016) , supply of full hd p/t/z (pan/tilt/zoom) ip colour camera as per rdso spec. no: rdso/spn/tc/ 65/2021 rev 6.0 or latest with amendment-1 or latest. this also included all required accessories as per instructions of the site in charge. , supply of full hd ip colour camera as per rdsospec. no: rdso/spn/tc/65/2021 rev 6.0 orlatest with amendment-1 or latest. this alsoincluded all required accessories as perinstructions of the site in charge , supply of wireless router/ access point for wi-ficonnectivity as per technical specification , supply of ont with dual- band wireless ac/n ggpon hgu with 4-port gbe lan and rf overlay as per technical specification , supply of 64 channel network video recorder and 64tb storage after raid 5/6 configuration with hdd (8 nos of hdd, capacity: 8 tb each should be supply along with nvr), 2 no's ethernet port complete with all other accessories as per rdso spec. no. rdso/spn/tc/65/2021 ver6.0 or latest, clause no.10.2. the software licenses should be as per rdso spec no.: rdso/spn/tc/65/2021 rev 6.0 or latest clause 20.0. , supply of iron cage for protection of cameras , supply of stp cat-6 cable (shielded twistedpair) stp compliant with latest tia/eia568c.2 , supply of network attached storage (nas) device, on site oem warranty 3 years. ,
Tender For selection of si for design, supply, installation, testing and commissioning of mpls vpn managed network services with rf as last mile based for wcl nagpur with comprehensive annual maintenance contract for a period upto 22.03.2028 on opex basis.
Tender For supply of vector signal generator , vector signal analyser , digital storage oscilloscope , digital multimeter , vector network analyzer , radio test set with rf and audio analyzer , ate accessories , sut integration and test gui development