Get complete information related to latest Vibration Controller Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vibration Controller Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vibration Controller Tenders.
Tender For supply of 250ma for mhs, maithon, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for phps, panchet, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for mhs, maithon, dvc , sync. transformer for scr controller unit for 150a float-cum-boost charger, 0-270- 300v_80-0-80v, 100ma for phps, panchet, dvc , sync. transformer for scr controller unit for 150a float-cum- boost charger, 0-270-300v_80-0-80v, 100ma for mhs, maithon, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for phps, panchet, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for mhs, maithon, dvc , blocking diode for battery charger for phps, panchet, dvc , blocking diode for battery charger for mhs, maithon, dvc , ac supply fail relay card static type 415v ac for phps, panchet, dvc , ac supply fail relay card static type 415v ac for mhs, maithon, dvc , semiconductor protection fuse, high speed, 200a for phps, panchet, dvc , semiconductor protection fuse, high speed, 200a for mhs, maithon, dvc , thyristor 150a, 1200v _h150tb12 for phps, panchet, dvc , thyristor 150a, 1200v _ h150tb12 for mhs, maithon, dvc , battery protection fuse _200 a hrc type for phps, panchet, dvc , battery protection fuse _200 a hrc type for mhs, maithon, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for phps, panchet, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for mhs, maithon, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for phps, panchet, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for mhs, maithon, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for phps, panchet, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for mhs, maithon, dvc
Tender For supply of sterile water 500ml bottle , t-piece resuscitator with adjustable peep controller disposable circuit , air vo2 tubing with humidifier infant
Tender For supply and commissioning of oil chiller unit with the following specification: (1) rated operat ing voltage: 3phase, 415 v ac, 50 hz (2) nominal cooling capacity: 9,000 kcal/h/10.4 kw/3.0 tr (3) refrige rant used: r-407c or any environmental friendly refrigerant with lesser gwp. (4) medium of cooling hydrau lic oil viscosity grade: is0 vg 32 to 68 cst @ 40-degree c (5) duty type: indoor, continuous duty type (6) p umping capacity: minimum 40 lpm, geared pump with 3 phase, 415 v ac, motor (7) tank: without storage tank (8) temperature range ambient: +15-degree c to +45-degree c (9) temperature range of medium: + 15-degree c to +35-degree c (10). oil connection both suction & delivery: 1" bsp (11) type of enclosure: i ndustrial enclosure (12) compressor: hermetically sealed, air cooled, reciprocating/scroll compressor. (13 ) condenser: air cooled condenser, made of copper tube with aluminium fins, air inlet from the side & air o utlet on the top. (14) evaporator: stainless steel brazed plate heat exchanger (15) drier: filter drier (16) ex pansion device: expansion valve (17) pressure switches: low/high pressure switches (18) temperature co ntroller cum display unit: microprocessor based, programmable controller with digital display (19) auxiliary contact: potential free contact for general alarm 1 no & 1nc (20) motor protection: all motors with motor p rotection circuit breaker (mpcb). (21) conforming to ce compliance. [ warranty period: 12 months after t he date of delivery ]
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above