Web Analytics Made Easy - StatCounter

Vibration Isolator Tenders

Get complete information related to latest Vibration Isolator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vibration Isolator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vibration Isolator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40978294 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For supply of impeller f/fan cd 84, cb doctor pvt ltd , anti vibration isolator ag2, cb doctor

State Government

CTN :40602511 Due date: 14 Jul, 202514 Jul, 2025 2.93 Lacs
Tender For corrigendum : carriage of various equipments materials diverted from various ss for new 160 mva tf-iii bay and replacement of 132 kv isolators and 132 kv bus pt at 220 kv ss etah under etd mainpuri

State Government

CTN :40983199 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For re-arranging of existing 'suspending type' 33kv feeder bay line isolators (16nos) to "horizontally mounted type" at 220kv ss moulali.

State Government

CTN :40950747 Due date: 18 Jul, 202518 Jul, 2025 1.77 Crore
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc

corporations/Associations/Others

CTN :40952815 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For ttps es circle em ii annual maintenance of lt switchgear lt breakers modules bus bars and isolators during the overhaul period of 25 26 at ahp stage ii

CTN :40603185 Due date: 07 Jul, 202507 Jul, 2025 21.50 Lacs
Tender For corrigendum : erection/extension and repairing work of 33 kv/11 kv/lt lines/pole and increasing capacity of 11 kv s/s, add. dt installation, replacement of damaged vcb panels, install. of line isolators and replacement of jarjar/damaged cond. under edd atarra

corporations/Associations/Others

CTN :40737358 Due date: 22 Jul, 202522 Jul, 2025 91.51 Crore
Tender For corrigendum : purchase of various class isolators for year 2024-25 & 2025-26 as per latest technical specification on firm price basis against tender no. ce(p&c)/ace(p&c)/ee(proc)/iii/e-3021/ various class isolators/2024-25 & 2025-26

State Government

CTN :40915404 Due date: 25 Jul, 202525 Jul, 2025 1.17 Lacs
Tender For erection work of 132 kv tendum isolators at 132 kv s/s foundry nagar under etd-ii agra

State Government

CTN :40934540 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For repairing of isolator rotating head assembly of 66 kv isolators (g-nandi make) at 220kv s/stn. sarita vihar

corporations/Associations/Others

CTN :40941624 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For various ratings of hrc fuses and various capacity of miniature circuit breaker and isolators
 Loading, Please wait...

Connect us via What's Up