Tender For providing of calibration services - calibration of fuel nozzle manifold test station; calibration of fuel nozzle manifold test station; nabl labs, csir labs, any other government approved labs / service provider; buyer premises (onsite)
Tender For supply of gasket , guide , spring , ferrule fuel manifold tube , clamp t bolt , cap kit , gasket , lub oil clr hsg , plug , expansion , clamp t bolt , cap screw , elbow male adapter , valve by pass , cap screw , knob , clamp hose , spring compressor , screw , pan head cap , plug , o ring , screw hexagon head cap , screw hexagon head cap , belt fan(c-51) , exchanger , heat , o ring , offset woodruff key , key , offset woodruff , union male , washer , cap screw , screw twelve point cap , gasket water pump , gasket water pump , bushing , shaft , fuel pump drive , gear tacho , flange crankshaft , element , seal , rectangular ring , diffuser , turbocharger , cover , fuel control , tube , water drain , screw , socket set , guide , valve steam , plug pipe , clamp hose , core cooler , guard belt , screw captive washer cap , screw , twelve point cap , seal , o ring , rod engine connecting , seal , o ring , vlave check , clamp v band , hose hump , valve pressure relief , pump , gear fuel , plunger , governor , control governor , plug , injector orifice , plug , injector orifice , spacer , mounting , screen filter , seal dust , injector , washer , plain , bushing , seal oil , gasket rocker lever housing , hose plain , gasket , exhaust manifold , insert valve , valve exhaust , piston ring set , screen , filter , housing actuator , sea water pump , dowel diamond , gasket , cover plate , screw , hex flange head cap , gasket after cooler cover , clip , tube , water transfer , tube , water transfer , insert rubber , shaft wtr.pump dr. , belt , vee , nut regular hexagon , kit inj barrel plunger , pulley sea water pump drive , seal , o ring , covar o ring , shield , turbocharger heat , screw , hex flange head cap , clamp v band , hose flexible , hose , flexible , hose , flexible , hose , flexible , slinger oil , injector , cover hand hole , coupling , bracket idler pulley , seal o ring , clamp , v band , pick up magnetic , hose flexible , gasket lub oil clr cover , element , air cleaner , seal , o ring , tappet valve , kit , upper engine gasket , seal , oil , shim , shim 002 , washer , plain , bearing trust , hose flexible , rocker arm hsg , coolant test kit - 3 way pack (set of 25 nos 3 way test stri , radiwash_5ltr , screw , hexagon head cap , elbow male adapter , screw , hexagon head cap , screw hexagon head cap , screw hexagon head cap , screw , hexagon head cap , nut heavy hexagon , washer lock , washer lock , tee , female pipe , sleeve , injector , head cylinder
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For seal piston cooling elbow to lube oil manifold pl no. 16170738 to emd pt no ? 8082587. to be procured from past proven source of same item in ir. warranty 30 month. test certificate, test button, test slab and warranty certificate to be send with supply. note: date of manufacturing, and fir m name to be printed on ring. [ warranty period: 30 months after the date of delivery ]