Get complete information related to latest Vibrometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vibrometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vibrometer Tenders.
Tender For supply of outdoor plinth mounted distribution transformer of rating 500 kva, 3-phase, 50hz , oil immersed, non-sealed type (transformer tank body and cover are bolted), primary winding in delta a nd secondary winding in star (vector symbol dyn11), onan cooled transformer, conforming to is 1180 (p art 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in cla use 20.1 of is 1180 (par1) latest with condition that drain-cum sampling valve will be applicable for all cap acity of transformers. oil temperature indicator & winding temperature indicators (for transformers above 200kva) will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/ iec 60137.the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provid ed as follows: a) for outdoor type: l.t. side b) for indoor type: h.t. side & l.t. side. along with following de tails: (i) kva rating of required transformer: 500kva (ii) no load voltage ratio: 6kv/415v-240v (iii) type o f mounting: plinth: (iv) the type of tap changer: off- circuit tap changer for variation of hv voltage from + 5% to -10% in steps of 2.5% (v) outdoor type (vi) energy efficiency level (latest)- 3 or higher. [ warranty p eriod: 30 months after the date of delivery ]
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficienc y level 3 of rating 500kva,3-phase, 11kv/415-240v, 50hz, oil immersed, non- sealed type (transformer ta nk body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (ve ctor symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1 terminal arrangement: the transformers shall be fi tted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage si de cable end box required. the high voltage bushings (3nos.) shall conform to is/iec 60137. the low voltag e bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 k va) for variation of hv voltage from +5% to -10% in steps of 2.5%. [ warranty period: 30 months after th e date of delivery ]
Tender For corrigendum : supply of w90311941141 oil module unit as per document no. 4-11939-j3500 size: l2 , w99311941638 pressure relief valve of jacking oil system (l2-module) kks tag: mav35aa151 set pressur , w99311939854 complete assembly of main oil pump without motor with compl ete coupling (design q= 69 , w99311939463 complete assembly of emergency oil pump with dc motor for l2 oil module , w99311939447 complete assembly of lifting oil pump with ac motor size: t7e 050 , w99311941646 following spares for 3way temp erature control valve for l2 module: 1. valve trim (incl , w99311941620 oil throttle valve in lube oil header for l2-module kks tag: mav21aa251 size: l2 , w99318137273 bearings of ac motor for lube oil centrifugal pump for oil module-l2 , w99318137338 bearings for ac motor of lifting oil pump for oil module-l2 , w99318137532 bearings for ac motor for oil mist seperator (oil vapour exhauster) of oil module-l2 , w99318137265 ac motor for lube oil centri- fugal pump of oil module-l2 (147.2 kw, 3000 rpm) , w99318137320 ac motor for lifting oil pump for oil module -l2 (82.8 kw, 1500rpm) , w99318137516 ac motor for oil mist seperator( oil vapour exhauster) of oil module-l2 , w99318137400 carbon brushes for dc motor of emergency oil pump for oil module-l2 , w99318137486 carbon brushes for dc motor for lifting oil pump of oil module , w99318137419 brush assembly for dc motor for emergency oil pump of oil module-l2 , w99318137494 brush assembly for dc motor for lifting oil pump of oil module , w99318137389 dc motor for emergency oil pump for oil module-l2 (28.2 kw) , w99318137575 dc motor for lifting oil pump of oil module , w99318137397 bearings for dc motor of emergency oil pump of oil module-l2 , w99318137478 bearings for dc motor for lifting oil pump of oil module , w99318137052 pressure transmitter for oil module, range 0-250 bar , w99318137060 pressure transmitter for oil module, range 0-6 bar , w99318137079 pressure transmitters for oil module, range 0-(-15) mbar , w99318137087 level transmitters for oil module l2, range (850-1750) mm , w99318137192 pressure switch for oil module, range- (0.5-10) bar , w99318137206 differential pressure switch for oil module, (0-4.2) bar , w99318137214 differential pressure switch for oil module, (0-1.2) bar , w99318137125 rtd for oil module, range- (0-100) degc , w99318137095 level indicators for oil module l2, range-(850-1750) mm , w99318137150 pressure gauges for oil module, range- (0-10) bar , w99318137168 pressure gauges for oil module, range-(0-400) bar , w99318137176 pressure gauges for oil module, range-[ (-) 60-0] mbar , w99318137184 pressure gauges for oil module range -[ (-) 160-0] mbar , w99318137141 temperature indicator for oil module, range- (0- 100) degc , w99318137915 pressure transmitter for oil module, range 0-10 bar , commissioning spares as per document no. 4-11939-om013 rev 01 (one set of commissioning spares shoul , lump sum per man day charges at site, including every expense at our site i. e. boarding & lodging, l , lump sum per visit charges (to&fro) including travelling time & all expenses up to our project site
Tender For standing order/rate contract for supply of instrument materials on door delivery and callup basis at hbl plant sugauli, east champaran and lauriya, west champaran, bihar. - load cell 100 kg strain gauge type, make-avery/ perciamoleen, 4 load cell junction card 4 input 1 out, make-avery/ perciamollen, signal isolater optical isolation type signal input/output 4-20 ma supply 18- 260 vac/vdc, make-radix, signal converter 0-5 a to 4-20 ma supply voltage 18-240 vac/vdc, make-radix./masibus/ p&f, zss controller with its proximity supply voltage 230vac, make-masibus, hall s effect type top roller lift sensors (asd-he-trls-10) and indicating transmitters (asd-he-trlit-1005-1-2), make-yu tech, infra red type donnelly chute level sensors, indicators & transmitters, make-yu tech, hall s effect type cane blanket level sensors( asd-he-cbls-10) and indicating transmitters (asd-he-cblit-1005-1-2), make-yu tech, pressure transmitter strain gauge type range 0-16 kg/cm2 output 4-20 ma loop powered processe connection 1/2 inch male threaded, make-honywell/ypkogawa, on off controller input signal universal, 2 relay output on set point, make-honywell, size 96x96 supply 230vac, weighing controller/ indicator for beltscale model no=40 bs, make-percia mollen, directional control solenoid operated valve (ng10): 4we 10 d a01-24dg/v, make-hydac, direction control valve, solenoid operated (ng6) type: 4we 6 d a01-24dg/v, make-hydac, pressure relief valve sandwich plate type for ng06(4we 6 d a01-24dg/v), pressure range 210 kg/cm2flow 120 l/min, manual adjustment, fkm sealing, make-hydac, electronic pressure indicator cum transmitter range 0- 300 kg/cm2 model no eds 3000, make-hydac/ above equivalent, make parker, strain gauge type dp switch across filter, make-hydac/ parker, pnp pproximity switch 2 wire range 15 mm od 15 mm male supply 24 vdc p&f, lvdt range 0-1100 mm probe od 10 mm 1/2 inch threaded connection, out put 4-20 ma model no. c01-1100-000 make hydac/ above equivalent, make-mts, model no. rhm1185md601a01, level indicator cum transmitter loop powered output 4-20 ma range 1000mm fluid hydaulic oil, make-parker, part no. 110558, model no. hblt-a1-6u, digital temperature indicator cum transmitter head mount range 0-100c probe od 8 mm loop powered output 4-20 ma, make-hydac/ parker probe length 700mm, solenoid coil connector 4 pin with led indicator, size-20mmx20 mm, lvdt probe connector with 10 mtr cable lid connector type 6 pole, m16 din female type, make-any reputed, plug in power relay with base, coil voltage 24 v dc model no my2n, make-omron, rtd pt100 type length 500mm od 6 mm, temperature transmittercum digital indicator remote field mounting input universal, loop powred, output 4-20 ma, make-rosemount/ honywell/abb/ yokogawa/p&f, 8 channel rtd transmitter input rtd pt100( field interface boards 8 channel linearized rtd/tc input), output 4-20 ma model no-mas-ai-u-o8d-9-1-0, make-masibus, pressure transmitter lvdt type range minus 2 kg/cm2 to 16 kg/cm2 loop powred output 4-20 ma 1/2 inch female threaded process coneection, field mounting hart enable, make-abb/ emerson/ rosemount/ yokogawa, diffrential pressure transmitter range minus2 kg/cm2 to 5 kg/cm2, field mounting process connection 1/2 inch ntp female threaded loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/ emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at higher side loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/ emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at both side 4 mtr capilary, loop powered 4-20 ma output hart enable, make-abb/ yokogawa/ rosemount/ emerson, perssure gauge burden tube type range 20 kg/cm2 dial size 6 inch process connection 1/2 inch ntp male threaded, make-warri/ hguru, perssure gauge burden tube type range 10 kg/cm
Tender For supply of vibrometer ipc-707 signal conditioner model 244-707-000- 012-a1-b1-c4905-d4-e10-f10000-g1 , vibrometer ipc-707 signal conditioner model 244-707-000-012-a1-b1-c9810-d4- e10-f10000-g1 , vibrometer galvanic separation unit model 244-127-000-021-a1-b04 , vibrometer tq 401 proximity transducer model 111-401-000-013-a1-b6-c023-d000- e010-f0-g000-h05
Tender For supply of outdoor type, plinth mounted, oil immersed, copper would, non-sealed type (transformer ta nk body and cover are bolted) distribution transformer 500 kva rating, 11 kv/415v, 3-phase, 50hz, primar y winding in delta and secondary winding in star (vector symbol -dyn 11) onan cooled, off-load tap chan ger for variation of hv voltage from +5% to 10% in steps of 2.5%, with all standard fittings as per clause 2 0.1 of is 1180 (part 1) and oil temperature indicator & winding temperature indicators, drain-cum-sampling valve with steel plug, energy efficiency level - 2 and above, conforming to is 1180 (part 1):2014 with amen dment nos. 1,2,3 and 4 or latest. make and description: as per latest cee description no ser/elec/gs/des cription/trans/4/rev-0/oct 2023, vide ltr no cee/s/185/519/genl. dated 10/10/2023 or latest, issued fr om pcee office time to time. make: indian make is approved [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of oil module unit as per document no. 4-11939-j7500 size l2 , oil module unit as per document no. 4-11939-j7500 size l2 , oil module unit as per document no. 4-11939-j7500 size l2 , complete assembly of main oil pump without motor with compl ete coupling (design q- 69.4lps design pr- 6+/-0.3bar) size l2 , complete assembly of jacking oil pump with ac motor with complete coupling (l2-module) size l2 , complete assembly of jacking oil pump with dc motor with complete coupling (l2 module) size l2 , emergency oil pump with motor with complete coupling for l2 module size l2 , following spares for duplex filter lube oil for l2-module 1. filter elements - 1 set 2. orings/gaskets - 1 set (one set is defined as number of items in both sides of filter housing) size l2 , basket strainer for main oil tank of l2 oil module size l2 , following spares for lifting oil filter (l2 oil module)- 1. filter elements - 1 set 2. orings/gaskets - 1 set (1 set is equal to items in both side of filter housing) size l2 module , drg l2 rev jacking oil pump pressure relief valve (safety pressure relief valve) for l2 module kks tag no. mav31/32 aa191 set pressure 200bar , startup valve of jacking oil pump mav31aa701 size t7e050 , pressure relief valve of jacking oil system (l2-module) kks tag mav35aa151 set pressure 155bar size l2 , ac motor for lube oil centri- fugal pump of oil module-l2 (147.2 kw , 3000 rpm) , ac motor for oil mist seperator( oil vapour exhauster) of oil module-l2 , dc motor for emergency oil pump for oil module-l2 (28.2 kw) , dc motor for lifting oil pump of oil module , pressure transmitter for oil module , range 0-250 bar , pressure transmitter for oil module , range 0-6 bar , pressure transmitters for oil module , range 0-(-15)mbar , level transmitters for oil module l2 , range (850-1750)mm , pressure switch for oil module , range- (0.5-10)bar , differential pressure switch for oil module , (0-4.2)bar , differential pressure switch for oil module , (0-1.2)bar , rtd for oil module , range- (0-100)degc , level indicators for oil module l2 , range-(850-1750)mm , pressure gauges for oil module , range- (0-10)bar , pressure gauges for oil module , range-(0-400) bar , pressure gauges for oil module range - ((-)160-0) mbar , temperature indicator for oil module , range- (0-100)degc , lube oil vapor exhauster fan with ac motor for l2 module (1 set is equal to items in one side of vapor exhauster) size l2 module , ac motor for lifting oil pump of oil module , drg 418101f9010a rev 00 resistance box for dc jop motor , drg 418101f9010a rev 00 resistance box for dc eop motor , commissioning spares as per document no. 4-11939-om013 rev 01 (one set of commissioning spares should be items of 2 x clause a + 1 x clause b of document no. 4-11939-om013 rev 01) , commissioning spares as per document no. 4-11939-om013 rev 01 (one set of commissioning spares should be items of 1 x clause a + 1 x clause b of document no. 4-11939-om013 rev 01) , lump sum per man day charges at site , including every expense at our site i.e. boarding & lodging , local travel etc. for supervision of commissioning , lump sum per man day charges at site , including every expense at our site i.e. boarding & lodging , local travel etc. for supervision of commissioning , lump sum per visit charges (to&fro) including travelling time & all expenses up to our project site for supervision of commissioning , lump sum per visit charges (to&fro) including travelling time & all expenses up to our project site for supervision of commissioning