Get complete information related to latest Video Splitter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Video Splitter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Video Splitter Tenders.
Tender For provision of ipis along with auto announcement pa system at pf no.-01 to 10 and circulating area, cctv system along with led panel based train indication board (tib) at patna jn. under danapur division.
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For comprehensive annual maintenance contract (camc) of infosoft digital design and services pvt. ltd, new delhi make with rdso specified cib/cgs,tib, outdoor & indoor videowall , auto announcement system with others accessories at mldt,nfk ,jrle, sbg,ppt, svrp, sbo, sgg,jmp, mgr,,baka ,goda & rjl for three years.
Tender For provision of coach guidance display boards and train information display boards at 11 number of abss stations of delhi division of northern railway and balance work in c/w provision of coach guidance system at nno, ssb, nur, bvh, & passenger amenities (telecom) at newly constructed platform at anand vihar railway stations and ipis auto announcement, tidb etc at stations where train handling facility is to be started due to station redevelopment of ndls station.
Tender For outsourcing of man-power for operation of coach indication board, train indication board, auto and manual announcement system and face to face enquiry, telephonic enquiry, coach guidance boards and other allied works pertaining to passenger announcement and information facilitation at bhubaneswar, cuttack, khurda road, puri, bhadrak, jajpur keonjhar road, brahmapur, balugaon, palasa, dhenkanal, angul, chatrapur, ichchapuram, sompeta, mancheswar, khallikot, lingaraj temple road, talcher road, nirakarpur, kaluparaghat, sakhigopal railway stations & commercial control of khurda raod division for a period of 482 days from the date of commencement of work.
Tender For corrigendum : supply of ptz dome camera 30x or better with mount bracket power supply and media converter etc , 2 megapixel fixed day night ip camera or better with mount bracket power supply poe injector and media conveter etc. , network video recording server with 45 days recording backup including vms software and required licence and workstation , poe switch 24 port giga ethernet 4 sfp port , poe switch 8 port giga ethernet 2 sfp port , sfp module 10g , 8 port unmanaged switch , indoor rack 9u with 24 port jack pannel fully loaded , outdoor rack 6u , 6 core ofc armored cable , sc lc ofc patch cord 3 mtr , 24 port liu loaded , 12 port liu loaded , hdpe pipe 32mm , pvc pipe 25 mm , stp cat 6a cable 305 mtr , utp cat 6a cable 305 mtr , utp cat 6a patch cord 2 mtr , utp cat 6a patch cord 1 mtr , i o cat 6a with face plate and backbox , stp rj 45 connector , power cable 1.5 sqmm 3core , armoured power cable 4 sqmm 3core , electrical junction box , surge protector , lighting arrester with chemical earthing , 3 mtr camera pole with self supported and earthing , 55 inch led display including hdmi cable of required length , video extender for display , videosplitter for display , installation integration testing and commission of the all equipments of the cctv survillance project including warranty of one year , post warranty comprehensive amc of all itmes i.e. active and passive used in the cctv survillance project of this location for three 03 years , ptz dome camera 30x or better, with mount bracket power supply and media converter etc. , 2 megapixel fixed day night ip camera or better, with mount bracket, power supply poe injector and media conveter etc. , outdoor acess point rf master , outdoor acess point rf slave , 01 kva online ups with 30minutes backup , 21 mtr tower with all accessories including lighting arrester with earthing , installation, integration, testing and commission of the all equipments of the cctv survillance project including warranty of one year , post warranty comprehensive amc of all itmes i.e. active and passive used in the cctv survillance project of this location for three years , ptz dome camera 30x or better, with mount bracket , network video recording server with 45 days recording backup including vms software and required licence and workstation. , indoor rack 6u with 24 port jack pannel fully loaded , lighting arrester with chemical earthing. , 3 mtr camera pole with self supported and earthing. , 10 kva online ups with 2hours backup , hdpe pipe 32 mm , installation, integration, testing and commission of the all equipments of the cctv survillance project including warranty of one year. , network video recording server with 45 days recording backup including vms software and required licence s and workstation. , post warranty comprehensive amc of all itmes used in the cctv survillance project of this location for three years , utp cat 6a cable , installation, integration, testing and commission of all components of lan including warranty of one year. //bid details 2 / 118
Tender For supply of computer based auto announcement system & technical specification as per annexure - 'a' [warranty period: 30 months after the date of delivery ]