Web Analytics Made Easy - StatCounter

Vinyl Film Tenders

Get complete information related to latest Vinyl Film Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vinyl Film Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vinyl Film Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45448930 Due date: 20 Jun, 202620 Jun, 2026 1.07 Crore
Tender For corrigendum : tender for supply of desluffer double layer instillation based wound healing system size medimum12x18x1 dash 2 cm compatible with cloud base npwt triage vac machine , desluffer double layer instillation based wound healing system sizelarge 15x26x1 dash 2 cm compatible with cloud base npwt triage vac machine , cycloflo double layer hydrophobic hydrophilic instillation based wound healing system medium size size 12 point 5 x 18 x 1 dash 2cm compatible with cloud base npwt triage vac machine , cycloflo double layer hydrophobic hydrophilic instillation based wound healing system large size 15 x 26 x 1 dash 2cm compatible with cloud base npwt triage vac machine , antimicrobial silver pu foam dressing small size 7 point 5 x 10 x 3 point 3cm compatible with cloud base npwt triage vac machine , antimicrobial silver pu foam dressing medium size 12 point 5 x 18 x 3 point 3cm compatible with cloud base npwt machine compatible with triage vac machine , antimicrobial silver pu foam dressing large size 15 x 26 x 3 point 3cm compatible with cloud base npwt triage vac machine , instillation canister with gel and solution delivery system 500 ml compatible with cloud base npwt triage vac machine , dynamic incision management kit size 4 point 5cm x 20cm compatible with dynamic incision management system , dynamic incision management kit size 4 point 5cm x 25cm compatible with dynamic incision management system , dynamic incision management kit size 4 point 5cm x30cm compatible with dynamic incision management system , dynamic incision management kit size 4 point 5cm x35cm compatible with dynamic incision management system , decellularized human dermis derived from donated human skin preserved in glycerol based solution with 97 percent plus of donor dna removed and sterility assurance level of 10 point 6 allowing for rapid cellular infiltration and revascularization ready to use without rehydration tensile strength of 635 point 4 plus 199 point 9n meshed form size 3x3cm , decellularized human dermis derived from donated human skin preserved in glycerol based solution with 97 percent plus of donor dna removed and sterility assurance level of 10 point 6 allowing for rapid cellular infiltration and revascularization ready to use without rehydration tensile strength of 635 point 4 plus 199 point 9n meshed form size 4x4cm , decellularized human dermis derived from donated human skin preserved in glycerol based solution with 97 percent plus of donor dna removed and sterility assurance level of 10 point 6 allowing for rapid cellular infiltration and revascularization ready to use without rehydration tensile strength of 635 point 4 plus 199 point 9n meshed form size 4x8cm , surgeon gown primary pluse meets , hyaluronic acid dermal fillers , dermal filler gel e point g juvederm , antimicrobial sacrum five layered highly absorbent foam dressing with activated carbon and sliver content 1 point 2mg obliq cm 2 active release for 168 hrs 7 days with self adherent borders and with soft silicone wound contact layer with wound pad absorption layer made up of polyacrylate fibres polyethylene polyester fibres with acquisition and spreading layer made up of polyurethane silver foam with polyurethane backing film as water bacterial and viral barrier a protective release liner made up of polyethylene film product should be usage dash upto 7 days size dash 23x23 cm , five layered self dash adhesive absorbent sacral dressing designed for exuding wounds with soft silicone adhesive wound contact layer with wound pad absorption layer made up of polyacrylate fibres and polyester fibres wound pad acquisition layer made up of polyurethane foam and spreading layer made up of non woven viscose polyester with polyurethane backing film as water bacterial and viral barrier a protective release liner made up of polyethylene film. product should be usage upto 7 days. size 22x25 cm , self adhesive 4 layered absorbent surgical dressing with soft silicone adhesive wound c

CTN :45546625 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of vinyl film colour golden yellow as per isc:356 of is:5-2007, in roll size of 4.5x150 feet, drg no. cc83117 alt-j, as per specification mdts-156, rev-7 with amendment-1, corrigendum-1 & corrigendum-2. packing instruction: pi042 [ warranty period: 60 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45594160 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of vinyl film colour golden yellow as per isc:356 of is:5-2007, in roll size of 4.5x150 feet, drg no. cc83117 alt-j, as per specification mdts-156, rev-7 with amendment-1, corrigendum-1 & corrigendum-2. packing instruction: pi042 [ warranty period: 60 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45532877 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th

Central Government/Public Sector

CTN :45532878 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For procurement of some consumable items - disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable medical grade non toxic and dehp free tubing with 200 micron filter clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing efficient roller control for better flow control molded bulb type injection site for extra medication approximately 20 drops, l ml dw sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. should be single line monitoring dome. should be measure invasive pressure., digital foetal doppler, eye drape sheet size: 80 x 75 cm - 90 x 75 cm adhesive area: 9 x 7 cm with 6 eye lid holders drainage pouch of transparent pe film eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,there should be a string each at all four, flexible annuloplasty ring - assorted sizes, complete

Central Government/Public Sector

CTN :45532880 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th

Central Government/Public Sector

CTN :45555978 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of exterior stickers for ac 3t amrit bharat coaches., as per drawing: lwaccn/pp2-8-3-002 alt annual repair w/o item 3,16 & 23, follow material spec. to rdso specification no. rdso/2006/cg-13 rev-01 option b (ref. md46271 dated 01.04.2025), packing instruction: exterior sticker/ marking diagram outside set of sidewall stickers should be rolled firmly on a cardboard tube/pipe of aprox. 03 inches diameter of sufficient strength and length more than sticker 2-3 inches of maximum width of sticker . endwall stickers of same set should also be rolled on seperate another cardboard tube/pipe (having similar dimensionaland strength parameter ) in same way. both tubes of one set should be packed together in a bio degradable transparent polyethylene packing. stickers or any edge ofsticker should not be found folded in packing. vinyl film side of stickers should be on the outside of tubes.these individual sets annual repaire further to be packed in card box (containing bulk quantity of sets). a list should be pasted on each set of transparent polyethylene packing and also on card box (containing bulk quantity of sets) showing pl no., item description, po no., name and address of supplier, date of manufacturing, lot number, lot quantity, list of items in a set etc. [ warranty period: 12 months after the date of delivery ] ]

Central Government / Public Sector

CTN :45551532 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For auction sale of - advertisement through vinyl wrapping for train no. 20701/20702 secunderabad-tirupati- secunderabad vande bharat express. advertisements are offered on the interior of the train only. the total area offered for advertisement is 6042.97 sqft. advertisements on sliding doors should be done through the one-sided vinyl film as per the terms enclosed. important note: - these advertisement rights inside of the train no. 20701/20702 secunderabad-tirupati- secunderabad vande bharat express are not sole advertisement rights and are only for the specific areas as mentioned in the special conditions enclosed.

CTN :45490265 Due date: 15 Jun, 202615 Jun, 2026 1.77 Lacs
Tender For removal and replacement of frosted vinyl film on glass partitions and tubular steel band over compound wall (sv road side) as per spa manual and allied civil works at andheri rspo, mumbai(2nd call).

CTN :45454161 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of vinyl film along with pre-spacer tape for complete lettering outside (color: cobalt blue as per ral 5013, golden yellow, white, signal red & black) in roll size of 2 x 150 feet as per specification mdts-156 rev-0. refer annexure-a for quantities of each colour. note- 1) self adhesive vinyl film shall be procured from the manufacture/oem who has got direct presence in india with their in-house testing facilities. 2)tender specific authorization from oem shall be provided at the time of bidding. 3) clause wise compliance to rcf specification mdts 156 rev 7 (latest revision) shall be provided at the time of tender bid. preferred make- reputed brands like 3m or avery dennison or similar. [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up