Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be
Tender For purchase of machinery/equipment for electrical trade for up-gradation of govt. quality marketing centre faridabad under trade infrastructure for export scheme(ties). - purchase of machinery/equipment for electrical trade for up-gradation of govt. quality marketing centre, faridabad under trade infrastructure for export scheme(ties)., salt spray chamber, digit mega ohm meter (0-250-500-1000-2500-5000 v selectable), glow wire test apparatus (test temp. range: 0-950 c selectable), kelvin double bridge (with accessories 1 dc source 2 spto reflecting galvanometer, digital), oxygen index test set, smoke density test apparatus, torsion test apparatus, digital optical measuring system (advanced vision system for dimension measurement)testing sample ranger 0-150 mm along with:-, insulation resistance tester-5kv, high voltage test set-2 kv dc, micro ohm meter-0-20 k ohm, ac breakdown tester-100 kv ac, universal bending compression tensile test 5 kn
Tender For corrigendum : supply of red insulated varnish "h" class epoxy insulation protection coating for winding cable of aux. machines in capacity of container of 500 ml (aerosole) quick dried with 121kv dielectric strength(at 28 degree c.) 5.7 kv breakdown voltage (0.05mm coating thickness) with excellent resistance to abrasion wear oil water acids and alkalis (as per specification clw spec. no. 4tms .092.106 alt-2 dated10.12.1992 and should pass the test as per is -10026-1982.) [ warranty period: 30 months after thedate of delivery ] ]
Tender For electric rubber hand gloves class 4 with 36 kv working voltage as per iec 60903:2014 or is 13774:2021 (rev-2) or latest without joint for electrical work usage, size-400 mm, palm size (circ.)- 10 inch, proof test voltage-40kv, breakdown/withstand voltage-50kv with minimum 1 year guarantee/warranty certificate and test certificate from prescribed institute or any govt authorized lab to be submitted at the time of supply. make: raychem, jayco or similar in reputed brand only [ warranty period: 12 months after the date of delivery ] ]
Tender For supply, commissioning & demonstration of motorized insulation oil breakdown voltage (bdv)test set having detailed specification as per annexure, make: ntpl otmt0605 or similar [ warranty period: 30 months after the date of delivery ] ]
Tender For supply,installation, and testing of bdv test kit for transformer oil : 100 kv automatic bdv oil test set for accurate breakdown voltage tests on mineral, ester and silicon insulating liquids.instrument with minimum 3" colour display, 12 key alpha numeric key pad. basic instrument with (a). 400ml vessel (as per iec 60156), (b). provieded with built in printer, (c).supply includes mushroom shaped electrodes, (d). magnetic stirrer, (e). programmed with iec 60156, astm & gost6581 test sequences. test voltage range : 100 kvrms. operating supply voltage: 230v,50 hz, single phase, with all necessary accessories as per specification attached. note: the firm must ensure full compliance with all columns of annexure and upload the completed annexure alongside the bid, else their offer shall be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply,installation, and testing of bdv test kit for transformer oil : 100 kv automatic bdv oil test set for accurate breakdown voltage tests on mineral, ester and silicon insulating liquids.instrument with minimum 3" colour display, 12 key alpha numeric key pad. basic instrument with (a). 400ml vessel (as per iec 60156), (b). provieded with built in printer, (c).supply includes mushroom shaped electrodes, (d). magnetic stirrer, (e). programmed with iec 60156, astm & gost6581 test sequences. test voltage range : 100 kvrms. operating supply voltage: 230v,50 hz, single phase, with all necessary accessories as per specification attached. note: the firm must ensure full compliance with all columns of annexure and upload the completed annexure alongside the bid, else their offer shall be rejected. [ warranty period: 30 months after the date of delivery ]