Get complete information related to latest Voltage Converter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Voltage Converter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Voltage Converter Tenders.
Tender For supply of microcircuit digital type spl fn ds 2438 , microcircuit linear type irf 7343 so 8 , bty 3v 235 mahlimno2 , battery 3v 950mah limno2 , elect conv dc to dc converter 20w , elect conv ac to dc
Tender For bid to ras supply of micro circuit linear type if amp mc 3372d , filter assembly 6 pin , microcircuit wideband rf spddt switch , ic dsp adsp 2189n bst 320 , converter ic digital dac 9762 , a7 fh syscon , ic fpga 1 programmed , microcircuit digital type x28hc 256ji
Tender For quotation for purchase of electronic components -battery charger 8s lifepo4 -29.2v 5a with xt60 connector ,24v 14.6a-350.4w smps (ac to dc converter) ,cytron smart drive mdds30 dual 30a (80a peak) ,soldering station ,xt90 male connector with housing ,voice recognition module v3 compatible with arduino ,max9814 high performance microphone agc amplifier module ,fluke 106 palm-sized digital multimeter ,m4 ss stainless steel hex nuts (50 pcs) ,m4x30mm socket head cap (allen) bolt and nut (12pcs) ,m3 x 20 mm socket head cap (allen) bolt-25 pcs. ,m3 ss stainless steel hex nuts (50 pcs) ,jumper wire (male to male) (40 pcs) ,jumper wire (male to female) (40 pcs) ,jumper wire (female to female) (40 pcs) ,aa 2000mah nicd/nimh battery - pack of 4 ,cc61n eneloop battery charger with usb cable
Tender For corrigendum : tender for supply of supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , spare - supply of digital tele-protection couplers with all acessories as per ts , spare - supply of e1 to optical converters as per ts , spare - supply of 6 core armoured optical fibre cable , spare- supply of line interface unit for upto 6 terminations ( switchyard side) , spare- supply of line interface unit for upto 24 terminations ( control room side) , supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , supply of digital tele-protection couplers with all acessories as per ts , installation , comissioning and testing of dtpc , spare - supply of digital tele-protection couplers with all acessories as per ts , supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , spare - supply of digital tele-protection couplers with all acessories as per ts , spare - supply of e1 to optical converters as per ts , spare - supply of 6 core armoured optical fibre cable
Tender For supply of 8-channel analog to digital converter, signal conditioner for 1/4-bridge 350 ohm strain gage , 12-channel accelerometer signal conditioning and digitalization
Tender For procurement and installation of ece lab equipments - procurement and installation of ece lab equipments, single output variable dc rpsu single output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, dual output variable dc rpsudual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, function generatorfrequency range: 0.1 hz to 2 mhz.display: 4 to 6 digit led displayoutput waveforms: sine, triangle, square, pulse, ramp.amplitude: 0 20 vp-p.rise time: 100 ns.distortion: 1% (within acceptable range of frequencies).power supply: ac 220 v 10%, 50-60 hzoutput amplifier protection: protected against short circuit and 15v overload, digital storage oscilloscopebandwidth: 50 - 100 mhz.sampling rate: 1gs/s.channels: 2 (minimum)power supply: 100v 240v ac, 50-60 hzautomatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc.,horizontal scale: 5 ns/div 100 ns/div or equivalentvertical resolution: 8 bits (2 channels simultaneously)vertical sensitivity: 1 mv/div 10 v/div (at input)waveform math: +, -, x , , invert, fft etc.,waveform storage: 16 waveforms or equivalentcommunication interface: usb host, usb interface.7-inch color display or equivalentbasic trigger functions, digital vo;tmeterdc voltmeter digital 3 digit display (0-100 v), 0.5 % accuracy (class 0.5 equivalent) (2000), digital ammeterdc ammeter digital 3 digit display (0-2 a), 0.5 % accuracy (class 0.5 equivalent) (1500), eliminator transformer (stepdown)input - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, embedded lpc 2148 kit cpu - lpc2148, core - 16/32 bit arm7dmi-s speed - max 60 mhz, flash - 512kb, ram (on-chip) - 40kb, 46 general purpose i/opins, usb2.0 one 10bit a/d converter with 14 analog inputs, one 10bit d/a converter, six pwm &watchdog two uarts (16c550), two i2c (400kb/s), two spi s eight bit digital output, eight bit digital input, 16 x 2 characters lcd and 4x4 matrixkeypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motordriver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connectorand usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board example programs in embedded c and assembly with documentation (soft copy) power chord, user manual with cd/dvd, free demonstration after delivery, single phase induction motorsingle phase induction motor, 230v ac, 50hz supply.power rating 1 hp (0.75 kw).speed 1440 rpm.capacitor start/run type suitable for lab useloading setup portable ammeter and digital tactometer contact type, single phase autotransformerinput - single-phase, 230v/240v, 50 hz, 4a, ac output - 0 to 270vac, class "h" or class f insulation., lvdt trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v /500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, strain guage trainer kitmetal foil strain gauge mounted on beam/cantileverstrain measurement under applied loadwheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltagezero and gain adjustment controlsprovision for applying calibrated loadsregulated power supply, 230 v ac, 50 hztable-top tr
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam