Get complete information related to latest Voltage Sensing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Voltage Sensing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Voltage Sensing Tenders.
Tender For supply of boq for supply of 05 types of electrical items for maintenance - electrochemical type gas monitoring equipment , visibility sensor system , on delay type electronic timer with range 0 30 sec 240vac , electromagnetic relay with 2 no 2 nc contacts rated for 5a 250 , thyristor ref no semikron 0241 skkt 57 b 16 e 0241 an
Tender For corrigendum : purchase of protection system spares for power house of parbati-ii hep - reb670 main-ii busbar protection relay , resisitor unit for rxmvb4 trip relay, rxtma , trip circuit supervision relay, tsr, coil voltage: 220v&110v dc, 2c/o, article no.: in 352 001-as , high speed trip relay, rxms1 , pushbutton module for trip relay, rxt - pb unit in5396 3001 -ac , test switch, rxtp18 , test pin , bistable relay rxmvb4 (rk251 403-ah)-pb2ph , numerical relay with 50,51,51n,27u,64r protection, ctr:- -5a, 3 di & 5do , static relay mvapm32d1aa2001a operating voltage vn 110v ac , dc supply monitoring relay - vaa11yf8752ca , aux relay,aux voltage 220-250v dc,2no+2nc,reverse flag,vaa11yf7752ca , two element aux. relay,s/r type, 2no+1nc with h/r operation indicator per element - vaa21zg0750ba , bistable relay - mvajm14jb1002a1 , bistable relay- mvajm14jb1004a1 , tripping relay,mvajm25la1004a,16 no+4 nc,h/r flag,burden high , tripping relay with s/r contacts - vajs23zg1000aba , aux voltage 110-125/220-250v dc,2no+2co,reverse flag,flush mount, model no: vax31zg0750ba , trip coil supervision,1no+2nc, s/r , h/r reverse operation indicator per element - vax21zg8045bch , no volt relay, voltage rating 63.5 v, 50 hz , voltage dropping resistor - 3.3 k ohms / 35 watt with base plate , metrosil resistor- s1088 , metrosil resistor - 1196 , stabilising resistor 0 to 1000 ohms , 20hz generator for 100% stator e/f protection relay , band pass filter with built in voltage divider for 100% stator e/f protection relay
Tender For supply of trip coil part no. me-4537 , closing coil part no. me- 4538 , auxiliary switch - 6 no plus 6 nc part no. me- 4541 , indicating lamp part no. me-4543 , push button with contact block part no. me-4545 , trip neutral close switch part no. me-4546 , hrc fuse link part no. mes-4710 , digital earth leakage relay 0.5 - 8 a, 80-300 v ac with cbct, door mounted part no. mes-4716 , single phase rectifier power pack - 110 volt part no. mer-5340 , 4p non-directional idmt static relay - 3o c and 1ef part no. mer-5510 , multi-functional energy meter 110v ac,3 phase,4 wire, a plus hz plus pf plus kw plus kva plus kvar plus kwh plus kvarh max. demand in kw kva, 8 channel part no. mer-5560 , h.d. resin cast current transformer - 200-100 5-5 a part no. md-2234 , h.d. resin cast current transformer - 400-200 5-5 a part no. md-2232 , negative sequence voltagesensing phase failure relay part no. mer- 5509 , fuse base part no. mes-4711 , fuse base holder part no. mes-4712 , maximum demand controller with av, kwh, kw, kvar, pf hd display part no. mer-5540 , complete vacuum circuit breaker truck draw out type manually operated-12kv-630 amp-26ka part no. medv-6193 , vcb finger contact with bolt, nut, sp. washer set of 24 nos. part no. mv-3325 ) /bid number : gem/2025/b/6571337 * /dated: 14-08-2025 & & / bid document 1 / 28
Tender For supply of intelligent multi-criteria detectors for upgradation of fire protection system , manual call point for upgradation of fire protection system , zone monitoring unit for upgradation of fire protection system , monitor module for upgradation of fire protection system , relay module for upgradation of fire protection system , loop powered remote hooters for upgradation of fire protection system , repeat response indicator for upgradation of fire protection system , fas control panel having 8 loop capacity with redundant cpu , zone indicating panel for upgradation of fire protection system , fire alarm control panel having 2 loop capacity with single controller , lcps -bare cabinets for upgradation of fire protection system , standalone ac to dc psu-smps for lcps for upgradation of fire protection system , hand- switches, push buttons, indicating lamps for upgradation of fire protection system , loop powered-cpu motherboard- backplane- bus powered relay modules with at least 8 change over contacts for upgradation of fire protection system , spares for fas control panel min. one type of each card or 10 percentage whichever is more standalone psu etc. , spares for relays other loose components and modules. for upgradation of fire protection system , test meter for smoke detectors , smoke detector removal tool kit with 6 m collapsible-concentric rod , smoke detector testing tool kit , aerosol gas cans 250 ml , heat detector tester , 1 pair 1.5sq. mm overall shielded hrpvc insulated frls pvc sheathed un-armoured cable for upgradation of fire protection system , 5 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 10 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 19 mm flexible gi conduit for upgradation of fire protection system , supply of 25 mm rigid hot dipped gi conduit including accessories , supply of nickel plated double compression brass cable glands , other accessories mcbs sealing compound etc , installation and commissioning of the system for upgradation of fire protection system
Tender For ac drive 37kw/50hp. supply & testing of ac drive specification; 1.ac drive required to drive squirrel cage im:37kw/50hp, 3ph, 415vac, 50hz, 4pole/6pole, s4 duty for crane hoist/ lt, appli cation. 2.ac drive mains supply:3ph, 380-400vac 50hz. 3.ac drive o/p rating, high overload capacity :37kw 4.drive o/p rating, normal ol capacity:45kw 5.panel mounting type, protection:ip-20 6.drive t o work without encoder feedback system with suitable current feedback system for speed control with required braking chopper, rfi & emc filter. 7.drive with inbuilt protection system: drive overload, exc essive load, ground fault, heatsink over temp., motor over load, over speed limit, over voltage, under voltage, short circuit etc. 8.ac drive to work from digital inputs in, up/down or forward/reverse di rection & in jog, start, stop, speed-1, speed-2 & speed-3 modes. 9.drive with standard minimum; 6 digital i/ps, 2 digital o/ps, 2 analog i/ps, 1 analog o/p & 2 relay o/ps. 10.drive shall have hmi with t ouchpad key mounted to display various operating parameters in english. hmi with editing drive para meters & self-monitoring watch dog facility to display fault & alarm indications. 11.drive software pro gram for crane duty be supplied in soft copy. 12. cable to communicate between laptop & ac drive b e supplied & operating manual in hard copy. 13.joint inspection at rwf, rwf will make necessary cab le connections to the rated capacity im & ac drive. supplier has to test ac drive for rated capacity ind uction motor on the crane/equipment & tuned parameters in soft copy. 14.make:danfoss vlt autom ation drive fc-302 series or ab power flex 755 series or siemens s-120 series or abb acs-880-m04 s eries or yaskawa ga-700 series only. 15.while tendering, firm to mention; make,series & complete m odel no & attach technical catalogue of ac drive with tender offer. 16. warranty: 18 months from d.o .supply or 12 months from d.o.commissioning, whichever is earlier. [ warranty period: 18 months a fter the date of delivery ]
Tender For supply of various spare parts for psi department - input contactor, add on aux contact, dvr contactor, auxiliary contactor, air break, in open execution, auxiliary contactor, auxiliary contactor, auxiliary contactor, air break, in open execution, auxiliary contactor with surge suppressor, auxiliary contactor with surge varistors, open/close contactor, dc supply supvn aux contactor, aux contactor, dc contactor, dc contactor, dc contactor, aux contactor, dc contactor, aux contactor, aux. contactor, add on contact block, add on contact block, add on contact block, auxiliary contactor, auxiliary contactor, fcbcs i/p contactor, dvr contactor, dvr contactor, bch i/p contactors, bch i/p contactors, contactor, contactor, contactor, dcdb incomer contactor, winding temperature indicator, oil temperature indicator, winding temperature indicator, oil temperature indicator, remote wti/oti, for wdg temp,oil temp, for tap position, winding temperature, fire alarm, mpcb, time delay relay, rtcc supply, indication supply, out of step, trip circuit supervision, trafo fault relay, dcdb earth fault relay, transformer protection relay, mtr,86, relay, auxiliary relay, aux relay, 8 step apfc relay with rs-485 port, led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (10mm), 25 mm ring, door limit switch, 2.5sqmm, open/close interlock release emergency stop p.b, release emergency stop p.b, push button with spring return, push button actuator red mushroom head nonilluminated, for alarm cancellation, raise/lower command/lamp test push button, overload relay, c/o relay, bridge rectifier, counter, smps, mechnical interlock (3 lock+2 key), i/p voltmeter, o/p voltmeter, digital voltmeter with builtin selector switch, dc voltmeter, digital voltmeter with inbuilt selecter switch, digital voltmeter with inbuilt selecter switch, anolog voltmeter, o/p ammeter, battery ammeter, digital ameter with builtin selector switch size 96x96sqmm, 3 , ammeter with inbuilt selector switch., dc voltage monitoring relay, voltage monitor relay with phase sequence, voltage monitoring relay nominal, voltage monitoring relay (phase & voltage control), fcbc o/p relay, fcbc o/p relay, fcbc boost relay, fcbc voltagesensing relay, relay (air breaker auxiliary contactor relay) (relay with base), multi function meter ctr-1/5a,cl-1 with comm.port rs-485nominal voltage, 415v ac aux voltage-230v ac/ 125-250v having following parameter v, a, f, pf, power, kwh, with tod etc., multifuction meter with builtin selector switch, 230vac aux supply;96sqmm, rs-485portcl-1, digital kwh meter., digital kwh meter., digital kwh meter., on delay timer, on delay timer, on delay timer, on delay timer, hrc fuse (rectifier fuse), bs type hrc bolted/closed slot, fuse base bs type hrc bolted /off settag, bs type hrc bolted/closed slot, control circuit fuse, control fuse with base, control fuse with base, fuse link, control hbc fuse, control hbc fuse base, input fuses, rectifier fuses, capacitor fuse, fuse for lighting, motor fuse, local/remote switch, breaker control switch (trip neutral close), motor switch, auto/manual selector switch, cooler auto/manual selector, door switch, local/remote, breaker cotrol switch with key (spring return), auto/manual selector switch, auto/manual selector switch, auto/main selector switch, local/remote selector switch, vcb auxiliary switch, local/remote switch, interlock switch with mech. lock, auxialry switch, charger on/off switch- cam type front panel mounting knob handle, ac i/p voltage selector switch, breaker control switch, miniature circuit breaker, miniature cir
Tender For insulation monitoring relay (imr) to monitor 3 phase power supply of voltage range 110 v ac , measuring range 1 - 100 k ohm, control voltage 24 - 240 v ac / dc output 1 c / 0 (spdt) contact system l eakage capacitance 10 micro-farad, and place of installation s1a6, as per rdso spec. no. rdso/pe/spec/a c/0184-2015 (rev.1) & bom lr.no. - el/7.1.108/mssbc dt. -17/09/2021 suitable for lhb type ac coaches s witch board cabinet (s1a06). acceptable makes as per bom: abb cat.no.cm.iws.1s, siemens cat no.3ug4 581-1aw31, only acceptable as per above rdso spec. (accepted make/brand: siemens, abb, schneider, d old, woka , bender, contrel only). specific makes, model no. and specification should be supplied as per vande bharat space concerned. [ warranty period: 30 months after the date of delivery ]