Tender For bid to ras supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volumecontroldamper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volumecontroldampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning o
Tender For supply of supplying of 1. 5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1. 5 tr inverter type ductable air cooled split ac unit as per item no. 1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2. 5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1. 5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volumecontroldampers , supplying and installing of 150 mm width 50 mm depth 1. 6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray