Get complete information related to latest Vswr Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vswr Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vswr Meter Tenders.
Tender For corrigendum : supply of ship pressure guage shockproof mkyx1 item code 9208142020 as per ta sl no 4 1 annexure i si 1 with documentationas per ta sl no 5 0 , inclinometer withmeasuring range 120 item code 9208142029 as per ta sl no 4 1 annexure i si 2 with documentationas per ta sl no 5 0 , impeller water meter bckm 90 25 item code 9208142049 as per ta sl no 4 1 annexure i si no 3 with documentationas per ta sl no 5 0 , storage 2 channel digital oscillography relative accuracy limits of the deflection coefficient item code 9208141033 as per ta sl no 4 1 annexure i si no 4 with documentationas per ta sl no 5 0 , multimeter standard error limits for dc and ac voltage item code 9208141034 as per ta sl no 4 1 annexure i si no 5 with documentationas per ta sl no 5 0 , megohmmeter measurement limits of isulation resistance from 0 to 1000 mohm item code 9208141035 as per ta sl no 4 1 annexure i si no 6 with documentation as per ta sl no 5 0 , microohmmeter grounding circuit resistance measurement limits from 0 to 100 item code 9208141036 as per ta sl no 4 1 annexure i si no 7 with documentation as per ta sl no 5 0 , multipurpose digital multimeter appa 103 n item code 9208141056 as per ta sl no 4 1 of annexure i si no 8 with documentation as per ta sl no 5 0 , digital storage oscillo scope item code 9208141070 as per ta sl no 4 1 of annexure i si no 9 with documentation as per ta sl no 5 0 , polarizing attnnuator item code 9208141075 as per ta sl no 4 1 of annexure i si no 10 with documentation as per ta sl no 5 0 , electronic frequency meter item code 9208141076 as per ta sl no 4 1 annexure i si no 11 with documentation as per ta sl no 5 0 , absorbed power wattmeter item code 9208141077 as per ta sl no 4 1 annexure i si no 12 with documentation as per ta sl no 5 0 , pulse generator g5 63 period item code 9208141078 as per ta sl no 4 1 annexure i si no 13 with documentation as per ta sl no 5 0 , high frequency signal generator item code 9208141079 as per ta sl no 4 1 annexure i si no 14 with documentation as per ta sl no 5 0 , oscilloscope fluke item code 9208141080 as per ta sl no 4 1 of annexure i si 15 with documentation as per ta sl no 5 0 , panoramic vswrmeter p2 60 item code 9208141081 as per ta sl no 4 1 annexure i si no 16 with documentation as per ta sl no 5 0 , magnetic measuring equipment item code 9208143009 as per ta sl no 4 1 annexure i si no 17 with documentation as per ta sl no 5 0 , steel plumb ot 400 min cord length 5 0 m item code 9208144008 as per ta sl no 4 1 annexure i si no 18 with documentation as per ta sl no 5 0 , liquid expansion thermometer glass type b item code 9208144044 as per ta sl no 4 1 annexure i si no 19 with documentation as per ta sl no 5 0 , engineers flat square item code 9208144098 as per ta sl no 4 1 annexure i si no 20 with documentation as per ta sl no 5 0 , vernier protractor 0 1800 item code 9208144027 as per ta sl no 4 1 annexure i si no 21 with documentation as per ta sl no 5 0 , urv55 rohde and schwartz milivoltmeter item code 7115120007 as per ta si no 4 1 annexure i si no 22 with documentation as per ta sl no 5 0 , microvoltmeter with frequency boonton item code 7115120009 as per ta si 4 1 annexure i si no 23 with documentation as per ta sl no 5 0 , frequency-selective voltmeter item code 7115120010 as per ta si 4 1 annexure i si no 24 with documentation as per ta sl no 5 0 //bid details 2 / 26
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
Tender For supply of laser interrogator system including hardware firmware and software gui d d ? g? g - design and development of laser integrator system including hardware firmware and software gui , supply of integrated laser card along with accessories and cables , supply of 5 wavelength channel master laser source assembly with dwdm module and chassis , supply of michelson interferometer assembly with acoustically isolation enclosure and cables , supply of interrogator and rtm pcbs along with cables and mechanical appurtenances and spares components , supply of standard vme 64x chassis with controller and display , development tool chain , spares and test tools , qualification test charges for laser system and interrogator unit