Tender For appointment of contractor/bidder for supply of material, erection, testing & commissioning for augmentation of 72 nos. existing 33 kv sub-stations (including civil work as per site requirements) on turnkey basis under revamped reforms-based and results-linked distribution scheme- 33/11 kv s/stn. items , 12.5 mva threee phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigam's technical specification with amendments relevant iss with latest amendments., , 33kv l & e switch (630amps), , 33kv isolators (630 amps), , 33 kv vcb, 36 kv, 1250a with 1000 mva (16 ka for 1 second) rupturing capacity vcb for out door use conforming to latest nigam's technical specification no. csc-24/r-ii/uh/dh/p&d/2020-21 with relevant iss & latest amendments thereof., , 33 kv c&r panel 24 v dc operated suitable for controlling one t/fs (with differential protection) as per nigam's tech. spec., relevant iss and latest amendments., , 33kv lightening arrestor sub-stn type 30kv 10ka with surge counter., , 33kv cts 600/300/5-5-5-5 with junction box, , 33kv pts with junction box, , 33kv post insulators, , disc fitting t&c type, , 11 kv vcb rating 1250 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for incoming panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for outgoing panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for capacitorpanel i/d type, , 11kv lightening arrestor sub-stn type 9 kv 10ka (heavy duty), , 11kv ncts 900/5a, , 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam's tech. spec., relevant iss and latest amendments, , structure for 33 kv cts (galvanized) wt. 87.62 kg., , structure for 33 kv pts (galvanized) wt. 87.62 kg., , structure for 33 kv la (galvanized) wt. 76.38 kg., , structure for 33 kv post insulators (galvanized) wt. 76.38 kg, , structure for 33 kv isolator (galvanized) wt.288.36 kg., , structure for l&e switch (galvanized) wt.288.36 kg., , structure for 11 kv nct (galvanized) wt.92.37 kg., , structure for cable stand, , gantry tower-2xdb-2, 2xdt-2, 2xdt-3 per sub-station, , structure for 11kv la/cable stand, , acsr conductor 80 sq mm(raccoon), , acsr conductor 0.2 sq in(panther), , 11kv single core xlpe cable 630mm², , 11 kv outdoor cable boxes for s/c 630 sq mm cable, , 11 kv indoor cable boxes for s/c 630 sq mm cable, , 11 kv xlpe cable 3 c x 300 sq. mm for capacitor bank, , 11 kv outdoor cable boxes for 3c x 300 sq mm cable, 11 kv indoor cable boxes for 3c x 300 sq mm cable, gi channel 100x50x6mm (gi) various size, gi angle iron 50 x 50 x 6 mm (gi) various size, gi flat 50 x 6 mm, gi flat 75 x 8 mm for earth mat in switchyard, earthing of s/stn. with pipe & earthing plate complete with machnary chamber, g.i pipe 40 mm dia 6 mtr. long for earthing set b class, premier synthetic insulating mat (class-b as per isi 15652:2006), pg clamps for panther conductor, gi nut & bolt off size, flood light led 240 watt (ip-67 rating), aluminium die cast body (make-, crompton, bajaj, phillips and havells only), 11 meters long pcc poles, un armoured copper control cable 2c x 6mm2, un armoured copper control cable 2c x 4mm2, un armoured copper control cable 7c x 2.5mm2, un armoured copper control cable 10c x 2.5mm2, un armoured copper control cable 3c x 4mm2, un armoured copper control cable 4c x 4mm2, un armoured copper control cable 6c x 4mm2, c-wedge connector for 0.2 sq. inch. panther conductor (nom. ai area, 200mm2), 33 kv polymeric disc insulators 70/90 kn b & s type, single tension fitting for 0.2 inch2 /150 mm2 acsr conductor, wooden cleat, ni-cd alkaline battery capacity (100ah) with static battery charger as, per nigam's specification., dry chemical type fire extinguisher (5 kgs), co2 type fire extinguisher (10 kgs), dry chemica
Tender For supply a set of the following spare for apfc panel as per the is: 13340-2012- 1) 3 phase power capacitor 5kvar as per bis standard is: 13340-2012 latest of make- abb, schneider, siemens. qty.- 25 nos. 2) 3 phase power capacitor 10kvar as per bis standard is: 13340-2012 latest of make- abb, schneider, siemens. qty.- 25 nos. 3) 3 phase power capacitor 20kvar as per bis standard is: 13340-2012 latest of make- abb, schneider, siemens. qty.- 25 nos. 4) power factor controller repaly card similar to hpl-pfcr80. of make- qty- 05 nos. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, fixing, testing and commissioning of 100 kvar apfc panel, with crca sheet of thickness 2.00 mm with 7 tank process powder coated, ip-54 consisting of the followings:- (1) main mccb 250 amp 3 pole 35/36ka - 01 no., (2) main copper bus bar tpn 400a capacity -01 set, (3) apfc relay 8 stage - 01 no. (4) led indicator r/y/b -03 nos, (5) mccb 100 a 3-pole 10 ka -02 nos. (6) mcb 40 a 3-pole 10 ka -02 nos.(7) mcb 32 a 3 pole 10 ka-01 no. , (8) mcb 20 a 3-pole 10 ka - 01 no., (9) mcb 10 a 3 pole 10 ka - 01 no. (10) mcb 6 a 3-pole 10 ka - 01 no. (11) contactor capacity duty type:- moc 25 for 25 kvar - 02 no. (12) moc 15 for 15 kvar- 02 no(13) moc 10 for 10 kvar -01 no. (14) moc 05 for 05 kvar -01 no.(15) moc 03 for 03 kvar -01 no.(16) moc 02 for 02 kvar- 01 no .(17) heavy duty capacitor :- 25 kvar - 02 no, 15 kvar- 02 no., 10kvar-01 no. 05 kvar - 01 no., 3kvar- 01 no., 2kvar - 01 no. (18) auto manual selector switch -08 nos. (19) led indicator on off- 16 nos. (20) control and power cable frls copper , ( 21) ct-as per requirement, including all accessories for commissioning complete in all respect as per direction of sse in-charge, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply. specification as per iec 61921/ is 8623/ is 16636/ iec 61439. make abb/ havells/ l&t/siemens or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, fixing, testing and commissioning of 200 kvar apfc panel, with cubical modular construction floor mounting dust and vermin proof made of 14/16 swg crca sheet as per latest approved specification is standard and harmonic block reactor with capacitors 25 kvar, 04 banks, capacitors 20 kvar , 02 banks, capacitors 15 kvar , 02 banks, capacitors 10 kvar , 02 banks capacitor 5 kvar , 01 banks, capacitors , 03 kvar , 01 banks, capacitor 02 kvar , 01 banks, comprising of housing, capacitors banks apfc relays, mccb/mcb protection, with all accessories including mounting arrangements suitable to work on 3 phase 440 volts,50 hz ac supply. features: automatically switch on and switch off relevant capacitor steps to ensure consistent power factor, continuously sense and monitor the load conditions by the use of the external ct ( whose out put is fed to the control relay), double side earthing connection, advance c-mos technology based microprocessor relay for intelligent power factor control, provision of top & bottom cable entry ,ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply, specification as per iec 61921/ is 8623/ is 16636/ iec 61439.makeabb/ havells/ l&t/siemens or similar. [ warranty period: 12 months after the date of delivery ] ]
Tender For corrigendum : supply of hv capacitor bank, 2600 kvar, 11kv(e) , hv capacitor bank, 2600 kvar, 11kv(e) with apfc panel , site supervision , training
Tender For supply of apfc capacitor bank panel - supply, instalation and commissioning of apfc capacitor bank panel with apfc relay with automating load control panel of 1250 kvr trail testing of apfc panel and outgoing supply of feeder will be connection and load trial. as per bellow detail specification make- l & t details of fabrication of panel cubical- free standing floor mounted with ismc chanel base 100x50x5mm front oprated indoor type ip44, powder coated, color-siemens gray ral-7035)hardwae, gasket,door lock, wiring, ferul etc sheet 2.2/1.6mmmm crca. note - 1-1- panel will be ms fabricated and powder coated as per industry standard, 2-all wires will be used fire proof standard. 3-the paneles muist be of iec/nec standards.4- all type of modification of old bus duct as per requiredment of sit.5- panel coolling axial fan 8inch/panel illumination lamps/thermo stat-30-90 degree.6-apfc relay microprossessor based-16 stage.7-acb used mdo 1.5g microprossessor based release uv., supply, instalation and commissioning with all bolts ,angle and supporting tool & takel with hardware as per requirerment of new aluminium bus bar grade- e91e with ducting, cap. 2,500 amp + 0.8 pf. all necessary conection will be done. make: hendalco
Tender For repairing of 3.3 kv grade 600 kvar capacitor bank with apfc panel, akanksha make, sl. no. akansha/pnl/21-22/087 installed at kdh 22.5 mva, 33kv/11kv-3.3kv old substation under kdh ocp, nk area
Tender For corrigendum : design, manufacturing, supply, installation, testing and commissioning of ht capacitor bank with apfc panel at ferro chrome plant, omc.
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitorpanelcapacitorpanel - apfc 200kvar capacitorpanel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitorpanel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of