Get complete information related to latest Waste Pit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Waste Pit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Waste Pit Tenders.
Tender For repair and maintenance of lwss mawa lohara in tehsil amb distt. una (hp) (sub head: improvement of leakage for excavation for dismantling, relaying, jointing and testing of gms pipe in lohara khad leakage & village bringal)
Tender For repair and maintenance of aug. wss chintpurni ji in tehsil amb distt. una (hp) (sub head: improvement of distribution system by excavation for dismantling, relaying jointing and testing of gms pipe and cutting welding due to leakage)
Tender For supply of misc safety and maintenance related jobs : : -sprinkler line repair with all fittings 2 inch , concertina coil repair , renovation of existing borewell , fabrication jobs with existing steel , supply fabrication and erection of structure steel , pcc 1 2 4 , rcc m25 , reinforcement , plastering 12mm , excavation upto 1. 5 mtr , excavation upto 1. 5 to 3 mtr , hard rock breaking upto 1. 5 m , brick work , structure painting , painting works on wall , writing painting on wall , welding inch dia , jcb hiring , hydra hiring , plumber hiring , carpenter hiring , tractor trolley
Tender For repair and lining work at the tunnel entrance of kundal distributary ch 1210 on the palus branch canal and removal of collapsed material from the deep excavation at km 4
Tender For 8825/token-127/2025-26 - demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and as directed., m&l for brick work with sub class b bricks old size bricks strainght or curved on plan exc 6m mean radius built in cm 1:6 omplete all as specified and as directed., all as per item no 2 before but except bricks, excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in soft/loose soil complete all as specified and as directed., returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as specified and as directed., removing excavated material not exceeding 50m and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specified and as directed., m&l for pcc 1:2:4 type b1 using 20mm graded aggregates as in surfaces channels and drains complete all as specified., m&l for cement concrete 1:2:4 type b1(using 20mm graded stone aggregate) as in blocks for hold fast, coping, benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces, complete all as specified and directed., taking down cement plaster in concrete or brick wall surface of any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified., m&l for rendering 15mm thick on fair faces of brick work or concrete surfaces in cm 1 : 4 mixed finished even and smooth without using extra cement complete all as specified., m&l preparation of old plastered surfaces of work and applying two coats of cement base paint all as specified and directed., s&f in repair 110mm bore pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc complete all as specified., s&f in repair 110mm dia of any radius pvc (swr) bends, s&f dwcpe(sn4) 150mm dia (internal dia) pipes,snap fit coupler and rubber ring incl testing and laid and properly jointed laid in trenches to a level on concrete bed including demlition of exiting pipes complete all as specified., s&f dwcpe(sn4) 200mm dia (internal dia) pipes,snap fit coupler and rubber ring incl testing and laid and properly jointed laid in trenches to a level on concrete bed including demlition of exiting pipes complete all as specified., s & f for precast plastic fibre reinforced cement concrete manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by ms sheet medium duty of overall size 1000mmx500mm & 75 mm thick complete all as specified and as directed., s & f for precast plastic fibre reinforced cement concrete manhole covers with frame medium duty of overall size 450mmx450mm & 50mm thick factory made all as specified and directed by engr-in-charge., s & f for precast cement concrete manhole covers with frame medium duty of overall size 300mmx300mm & 25mm thick factory made complete all as specified and directed by engr-in-charge., s & f for precast plastic fibre reinforced cement concrete drain cover including drain hole, grove and hook arrangement for lifting and placing in position and sides covered by ms sheet medium duty of overall size 1000mmx500mm & 75 mm thick complete all as specified and as directed., cleaning of ewcs, iwcs, bottle traps, nahani traps, gully traps and floor traps etc and ci/pvc pipes all types top to bottom including junctions etc, cleaning of sewage line upto gt in the area of pratap chowk and adjoining area(md accn and all types of accn). complete all as specified and as directed., cleaning of gts in the area of pratap chowk and adjoining area (md accn and all types of accn) complete all as specified and as directed., cleaning of manhole depth of upto 1.20mtr in the a
Tender For tender for supply of m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after re