Tender For corrigendum : supply of steam wateranalysissystem main spares and e and c c c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , conductivity analyzer -online retractable type , sample handling system for main steam superheated , sample handling system for main steam saturated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for condensate cep outlet inlet cooling wtr , sample handling system for dm water , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 6 mandays at manufacture works and 6 mandays at site , mandatory spares as per tech specs , supervision of e and c services charges at site , supervision of e and c visit charges
Tender For bid to ras corrigendum : tender for supply of co analyzer - co analysers along with accessories and commissioning spares for unit7 as per boq line item 1 , mandatory spares for co analysers of unit7 as per boq line item 2 , co analysers along with accessories and commissioning spares for unit8 as per boq line item 3 , mandatory spares for co analysers of unit8 as per boq line item 4 , co analysers along with accessories and commissioning for unit9 as per boq line item 5 , mandatory spares for co analysers of unit9 as per boq line item 6 , inst/commsng assist for co analyser for unit7 as per boq line item7 , inst/commsng assist for co analyser for unit8 as per boq line item8 , inst/commsng assist for co analyser for unit9 as per boq line item9
Tender For corrigendum : design, manufacturing, supply, installation and commissioning of online gas analyzer system for measurement of h2, co, co2, ch4 and o2 for ccu plant at thermax site, pune.
Tender For procurement of lab equipments for mechanical engineering department. - procurement of lab equipments for mechanical engineering department., exhaust gas analyzer: portable 5 gas exhaust analyser for automotive lab use measurement of, co (0-10 %) co2 (0-20%) hc (0 20000 ppm) o2 (0-25%) nox (0 5000ppm) gas sampling rate 01 lit / min response time = 5 seconds warm up time =03 minutes display lcd input membrane keyboard operating temperature - 0- 50 degree celsius power consumption 25 w, operates on 230 v ac / battery supplied with sampling probe, filters, and carrying case, 3d printer: build volume (wxdxh) 256 x 256 x 256 mm * shell enclosed (plastic & glass) hot end all-metal nozzle 0.4 mm stainless steel included max hot end temperature 300 nozzle diameter 0.4 mm (included) 0.2 mm, 0.6 mm, 0.8 mm (optional) build plate compatibility textured pei plate, cool plate, engineering plate, high temperature plate max build plate temperature 100 max speed of tool head 500 mm/s max acceleration of tool head 20 m/s supported filament pla, petg, tpu, pva, pet, abs, asa chamber monitoring camera low rate camera 1280 x 720/0.5fps time lapse supported filament run out sensor yes control board fan closed loop control auxiliary part cooling fan closed loop control air filter activated carbon filter, mitutoyo screw thread micrometer (0 -25 mm) mitutoyo screw thread micrometer 0 25 mm range; 0.001 mm accuracy; 0.005 mm/0.01 mm resolution; interchangeable anvils & spindle tips for multiple thread forms hardened measuring faces ratchet stop; calibration certificate protective case
Tender For corrigendum : providing of repair and overhauling service - maintenance works of steam and wateranalysissystem, silica analysers of dm plant and conveyor belt weighing system of lhs in tps-ii; thermal power plant; no; buyer premises
Tender For corrigendum : supply of steam wateranalysissystem main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For reer tender notice - purchase of non consumable item in thermal lab for mechanical department - open type air conditioning system kitcode - (d030)1.5 ton1. compressor type:open type capacity:0.5 tr to 1tr power 1 hp supply 230 v,single phase 50 hz2.condenser type: air cooled condenser material : copper tube with aluminium fins fan motor:230 v ac3.evaporator type :open fin type material : copper air circulation : blower assisted mounted openly for observation4. blower/fan type: centrifugal blower air flow : adjustable power:230 v ac5. refrigeration type : r226. measuring instruments pressure gauges: low&high pressure temperature:thermometers,digital sensors voltmeter : 0 to 300 v ammeter : 0 to 10 a temperature display : at inlet and outlet points energy meter: single phase, exhaust gas analysercode - (d037)to find the percentage of co,co2, o2, amount of hc and nox using exhaust gas analyzer. afr and lammda are measurable.