Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5188g (bmd-ii) - work of providing service of online oil purification / filtration of servo mesh sp-320 oil of coal mill xrp- 763/783/1003 at ukai tps on as & when re..
Tender For repair/ maint and servicing of filtration plant/ pump sets and other allied works at swimming pools of water supply installations of age e/m (ws) under ge (u) meerut cantt.
Tender For corrigendum : special repair to dg sets for water supply installations against ber and allied works at sector b and special repair to chemical dosing system for syl filtration plant under ge u ambala cantt
Tender For :purchase of chemistry laboratory equipment for basic engineering department - purchase of chemistry laboratory equipment for basic engineering department, hot plate: top plate material: cast iron ; plate size: minimum 8 inch diameter;power rating: 2000 w ; temperature range: ambient to 200 c minimumthermostatic temperature control: required; power supply: 220 240 v ac, 50 hz, ic regulated battery eliminator: ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., ammeter: dc (0 - 2 amp), voltmeter: dc voltmeter; range 10 v, analog, galvanometer: moving coil type, 30-0-30 scale, unbranded with bhel ; specification-sensitivity 0.143mm/v, waterdistillationunit: output capacity: 4 litres per hour (lph); ph value: 5.5 to 7.0 ; conductivity (raw waterdistillation):3.0 4.0 s/cm or less ; glassware material: borosilicate 3.3 glass (pyrex/duran equivalent); heating elements: silica-enclosed quartz heaters or chromium-plated element variants; power supply: 220 240 v ac,50 hz / 60 hz, single phase; automatic water level cut -off, electro analytical balance: load capacity: minimum 500 g; readability: 0.01 g; linearity: 0.02g; display: lcd/led; tare function: required; top pan type; power supply: 220 240 v; ac, 50 hz, electric bunsen burner: electrically operated, energy regulator/ control knob operating temperature 800 c ; body: stainless steel, power supply source: corded, electrically operated; energy regulator/ control knob, operating temperature 800 c ; body: stainless steel, power supply source: corded electric, supplied with a heavy-duty, heat-resistant, electric, supplied with a heavy-duty, heat -resistant, digital balance: weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For 8524/e8 repair/maint to water supply installation, swimming pool filtration plant and repair of leakage, cleaning and painting or certain over head tanks and other allied works at shahjahanpur cantt under ge (east) bareilly
Tender For corrigendum : providing of custom bid for services - repair work (supply of consumables and services) of fowler westrup make 6 kl tranformer oil filtration plant (tofp) at hvdc ballia station
Tender For corrigendum : repair replacement and maintenance of water filtration plant and swimming pool installation and connected wks and repair replacement and maintenance of environment park and drip irrigation system installed at vsn gandhinagar under ge(af) chiloda - repair /replacement and maintenance of water filtration plant and swimming pool installation and connected works and repair/replacement and maintenance of environment park and drip irrigation system installed at vsn gandhinagar under ge(af) chiloda