Web Analytics Made Easy - StatCounter

Water Heater Geyser Tenders

Get complete information related to latest Water Heater Geyser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Heater Geyser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Heater Geyser Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45722569 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of electric ceiling fan (v4) isi marked to is 374 , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 , exhaust fan pvc body 12" (300mm) sweep 230v, 50 hz , desert cooler bode size 48 inch (hight) , made from gi sheet

CTN :45609248 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : 1-1/2" inch lpg control valve without actuator , 3/4" inch pilot lpg regulator inlet pressure 7 psi max outlet pressure range 18 to 40 mbar , 1/2" inch pressure balance ratio regulator for lpg service , uv sensor for lpg burner flame detection , dn40 main gas regulator for lpg service 5 bar max inlet pressure outlet pressure range 85-180 mbar , ignition electrode for heater , pilot burner without ignition rod , 1-1/2 inch solenoid valve normally closed auto reset fofc with cpi switch for lpg service 240 volts , dn25 pressure relief valve for lpg service

CTN :44978519 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : procurement of “building spares and outdoor supply source. - geyser assembly 6-hole, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, geyser coil 2kw, geyser coil, 2 kw, 230 vac, 25 ltrs capacity, thermostat for geyser type-9-inch length, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, electric geyser neon indicator light red, 240v ac red indicator light pilot lamp, neon bulb, electric geyser neon indicator light green, 240v ac green indicator light pilot lamp, neon bulb, gyser model: ap-25v, cap:25ltrs, racold,crompton arno neo 25-l 5 star rated storage water heater (geyser) with advanced 3 level safetybrand cromptoncapacity 25 litres power source corded electricproduct dimensions 337.5w x 54.2h cmspecial feature auto restart, fast heating, geyser safety valve, for, 25 litre capacity geysers, make: crompton., cut out relay for geyser- type 9-inch, supply voltage-250v ac required for, 25 litre capacity geysers, make: crompton, ceiling fan, with copper winding coilnumber of blades-3, power consumption-52w, motor speed-380 rpm, design type-economy, type-ceiling fan, bee star rating-1, body material-aluminium, colour-white, 2 years company warranty, make-havells, crompton, bajaj, usha., portable type extension cable reel, without cable, portable i.e. lift & carryextension cable reel, heavy gaugetubular frame, sheet steel roller and al. discs with 2nos. m/c outletsocket 20a 3pin. reel capable of loading 50mtrs. 3core x 2.5mm.sq.pvc/pvc round sheathed flexible cable. (without cable)., power extension board - rating -15 amp, single phase extension board with 4core 2.5 sq.mm pvc insulated flexible cable (30 meter)component to be included in the board as bellow:1. 25a 2-pole mcb and 25a 2-pole rccb at incoming.3. 01 no s 1 phase 15a industrial socket with plug top and individual switch circuit4. 03 no s 1 phase 15a socket with individual switch circuit, industrial type extension box, fabricated from 16swg crcasheet of size 350mm x 250mm x 250mm. tower type powdercoated in deep orange shade gasketed doors conforming toip 55 and with the following components duly wired: -incomer: mcb and indication lampoutgoing: 4 no s f 10a socket & plug top each individuallycontrolled by a 10a dp rotary switch.

CTN :45635667 Due date: 03 Jul, 202603 Jul, 2026 6.08 Lacs
Tender For corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , household refrigerating appliances as per is 17550 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , washing machine - domestic purpose (q2)

CTN :45715657 Due date: 15 Jul, 202615 Jul, 2026 17.38 Lacs
Tender For tender for supply of erection and fabrication work b c c - juice/water scale ke weight channel bed mein se gale/kamzor channel ko kaatkar hatana. poorvanusar naya banakar lagana evam trial dena. , juice weighing scale ke filling tank ke rods ki kamzor/gali guides ko naya banakar lagana. , juice. maceration water evam final molasses ke weighing scale tank ke gale/kamzor bottom cone ko kaatkar purane anusar naya bottom cone lagana va poorn trial dena. , juice weighing system ke measured juice receiving tank ki gali/kamzor bottom evam side plates ko kaatkar hatana evam nirdeshanusar purani/nai plate lagakar leak.proof trial dena. , raw juice pump par lage catcher ko kaatkar hatana tatha naya catcher fabricate kar yathasthan lagakar samast connection poorv ki bhanti karna evam leak.proof trial dena. , pan. quad body evam vapour line juice heaters ki hydraulic testing ke liye inlet evam outlet ke vapour pipes mein cutting karke plate ke blind weld karna tatha hydraulic uparant blind kaatkar hatana evam vapour pipe ko punah andar va bahar se leak.proof weld karna. , semi kestner. vapour cell. quad body juice heater. vapour line juice heater ke condensate bottles tatha syrup receiving bottles ke cells ko kaatkar ceiling baffle plate ke kamzor hisse. bottom plate ke kamzor hisse athva cell ke kamzor hisse ko badalkar condensate bottles/syrup receiving bottles ki vanchhit marammat kar jal bharav parikshan dena. , juice heater mein lage ayatakaar juice entry box ko dismantle karna. gale/kamzor charon nipples badalna. double beat valves ki fitting hetu dono flanges lagana. box ki marammat kar box fit karna evam double beat valve fit karke leak.proof parikshan dena. , sabhi juice heaters ki gali hui sampoorn partition plate ko kaatkar bahar nikalna va nai 8/10 mm plate lagakar gili hui ring ko leak.proof welding karna tatha lagi hui tubes ko bachakar santoshjanak trial dena. , juice heaters mein dono taraf partition plate ki kamzor m.s. strip ko dismantle karna. kate face par grinding kar nai 25 mm x 5 mm ki m.s. strip banakar lagana evam rubber fit karna. , juice sulphiter ke recovery tower ke gale/kamzor bottom cone ko kaatkar 10/12 mm moti m.s. plate se sample anusar naya cone fabricate kar yathasthan fit kar leak.proof welding karna. , juice sulphiter ke base ke charon side ke gale/kamzor horizontal beams ki vanchhit strengthening hetu unke andar 12 mm moti plate lagakar majbooti pradan karna. , juice/syrup sulphiter ke kamzor bottom cones evam top cones ko dismantle kar sample anusar naya banakar fit karna. tatha andar va bahar se leak.proof welding kar santoshjanak jal bharav evam trial dena. , syrup sulphiter ke tower ki gali/kamzor baffle plates/jaliyon ko bahar nikalna. vanchhit marammat kar yathasthan fit kar leak.proof trial dena. , syrup pump se syrup sulphiter tak dono pumps ki delivery ki dono lines ko neeche utarkar garam karke. bhali bhanti safai karna. gali hui pipe line badalkar valve. bend. nipple ityadi lagakar punah lines ko fit karna evam leak.proof trial dena. , syrup/juice sulphiter ke upar lage recovery tower ko utarkar gali shell ko nirdeshanusar nai/purani plate se shell taiyar kar fit karna evam tower ko punah yathasthan lagakar leak.proof trial dena. , juice/syrup sulphiter/clarifier ke kamzor shell ke kamzor bhag ko kaatkar hatana. nirdeshanusar nai/purani 10/12 mm plate se banakar yathasthan lagakar andar va bahar se leak.proof welding kar trial dena. , sulphur bhatti (juice/syrup) ke gale/kamzor secondary gas cooler ko kaatkar hatana. 10/12 mm moti plate se purane ke anusar naya cooler fabricate kar yathasthan fit kar samast connection poorv ki bhanti kar leak.proof gas trial dena. , sulphur bhatti station par juice/syrup hetu sthapit sulphur bhattiyon ke gas coolers ke gale/kamzor cooling pipes ko kaatkar hatana. purane anusar naye pipes taiyar kar poorv ki bhanti fit kar leak.proof trial dena. , sulphur bhattiyon ke gale gas headers ko kaatkar hatana. purane anusar naye headers taiyar kar lagana. , sulphu

corporations/Associations/Others

CTN :45345524 Due date: 06 Jul, 202606 Jul, 2026 10.97 Lacs
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.

State Government

CTN :45452631 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : supply of electric ceiling fan (v4) isi marked to is 374 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2)

CTN :45696125 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply of equipment for mechanical engineering department - supply of equipment for mechanical engineering department, lathe machine :specification :bed: 2v & 2 flat, induction hardened and ground minimum bed length: 1375 mm bed width: 240 mm capacity: height of centre: 165 mm swing over bed: 320 mm swing over gap: 510 mm swing over cross slide: 180 mm distance between centres: 650 mm slides: cross slide travel: 200 mm compound slide travel: 115 mm spindle: spindle bore: 40 mm spindle nose: thread type, 62 mm spindle taper: mt-3 tail stock: quill diameter: 38.1 mm taper: mt-3 travel: 120 mm speed: no. of speeds: minimum 8 range: (40 800 )rpm threading: metric: (1 6 )mm (min 13 steps) english: (2 24 )tpi (min 19 steps) lead screw: (1 4) tpi electrical: motor: 1.5 hp, 230v/415v, 50 hz drive: v-belt structure: bed: close-grained cast iron (fg 260) gears: hardened steel base: rigid cast iron stand , open cup apparatus :specification :standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 6 c per minute (as per standard) temperature range: -6 to 400 c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valvebody: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hz safety: overheat protection heat insulation , closed cup apparatus :specification :standard compliance: astm d93 / is 1448 (part 21) test cup:brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustable ignition: pilot flame with automatic shutter mechanism temperature measurement: thermometer or digital sensor(ip-28c or astm) display: digital temperature display power supply: 230v ac, 50 hz safety:over-temperature cut-off flame safety control , tail stock assembly :specification :medium-duty tailstock assembly for dismantling & assembly quill stroke: minimum 75 mm taper: mt-3 (preferred standard) feed: hand wheel operated features: set-over screws for taper turning spindle locking arrangement body: cast iron (fg 260) spindle: hardened steel, slip gauge :specification :set size: m87 (87 pieces) or equivalent range: 1.001 mm to 100 mm step sizes: 0.001 mm 0.005 mm 0.01 mm material: high-grade alloy steel / tungsten carbide (preferred) hardness: hrc 63 65 accuracy: grade: grade 1 or grade 2 flatne flatness / parallelism: 0.5 m stored in protective wooden boxes to prevent wear; calibration grades include charts for exact sizes , dc motor:specification :type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel calibration grades include charts for exact sizes supply: mounted on training base suitable for dismantling and inspection , hydraulic operated directional control valves (dcv):specification :type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study , bearing with shaft assembly :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steelsupply:mounted on training base suitable for dismantling and inspection , coupling unit using driving and dr

CTN :45676692 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For purchase of fire safety and fighting laboratory equipment for fts department - purchase of fire safety and fighting laboratory equipment for fts department, cleveland open cup (coc) apparatus standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 c per minute (as per standard) temperature range: (-6 to 400) c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valve body: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hzsafety: overheat protection heat insulation, pensky-martens closed cup apparatus standard compliance: astm d93 / is 1448 (part 21) type: pensky-martens closed cup (motorized, digital type preferred) test cup: brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system: heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustableignition:pilot flame with automatic shutter mechanismtemperature measurement:thermometer or digital sensor (ip-28c or astm)digital temperature displaypower supply:230v ac, 50 hzsafety: over-temperature cut-off flame safety control

Central Government/Public Sector

CTN :45692970 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For procurement of seal gas heater of roni elektrogera tebau gmbh make for sgt 400 gas turbines of mh asset
 Loading, Please wait...

Connect us via What's Up