Tender For supply, delivery, installation and commissioning of dn600 electromagnetic flowmeter all complete with allied work for madhyamgram common delivery line at clear waterpumpingstation under madhyamgram municipal area.
Tender For repairing with replacement of worn out components, burn out winding of 2nos, 10hp capacity submersible pump motor sets at raw waterpumpingstation under grww.
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear waterpumpingstation and supply of 1 no empty chlorine tonner at intake kukrakuri under chhatna, saltora block sub-surface water based piped - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear waterpumpingstation and supply of 1 no empty chlorine tonner at ibs uporgora under chhatna, saltora block sub-surface water based piped water - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess
Tender For operation, cleaning including daily/periodic maintenance etc. of the sewage/underground waterpumpingstation....street light operation and maintenance etc. at howrah sub way complex under em sector, kmda for a period of 18(eighteen) months.
Tender For reorganization of 3.3kv oh power line for feeding 440v power to main pump and submersible pump and reorganization of 11kv oh line feeding power to pob plant near padmavati mandor under jambad ocp
Tender For tender for remove the worn out runners from the main bagasse carrier bagasse elevator and return bagasse carrier errect 8x65 10x50 mm flat iron bars in their place clean the welded areas using a grinder , cut and remove the worn out bottom plates of the main bagasse carrier bagasse elevator and return bagasse carrier errect new 6 8 10 mm , cut and remove the worn out side plates of the main bagasse carrier bagasse elevator and return bagasse carrier errect 6 8 10 mm plates satisfactory trial run , cut out and remove the damaged and weak sections of the main bagasse carrier fabricate and errect a new assembly including the gear shaft system using the supplied plate , cut out and remove the weak and corroded sections of the bagasse feeding chutes errected boilers fabricate and replacements using the provided plates and repair the associated shafts and gears , the casings of the boiler id and fd fans have become severely weakened and damaged the task involves cutting away and removing the weakened sections fabricating , cut and remove the deteriorated side bottom and top plates surrounding the air heater of boiler no. 3 fabricate and errect new plates using the specified 6 8 mm plate in their original positions , fully strengthen the air heater plates and conduct a satisfactory trial. , dismantling the old air heater tubes of boiler no. 01 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , dismantling the old air heater tubes of boiler no. 02 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , dismantling the old air heater tubes of boiler no. 03 size 63.5 mm od x 2.64 mm thickness fabricating and errecting new tubes in accordance with the drawing , a. dismantling old columns beam channels etc. b. manufacturing and installing new columns beam channels , installing 16 inch 18 inch manholes with blinds , constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to twenty hp , dismantling fabricating and erecting weak corroded pipe lines up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded tees up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting weak corroded nipples up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated cross member up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated band up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak throated flange up to 12 and providing satisfactory leak proof trials. , dismantling fabricating and erecting a weak sloping reducer up to 12 and providing a satisfactory leak proof trial. , removing the old corroded platform and replacing it with a new one