Tender For 1/2 inch air pressure regulator valve with pressure gauge ,range- 0-10 bar fitting 1/2 inch suitable for single wagon / coach test rig escort make . warranty - up to 30 months from date of supply. make- ask -15 , escort or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of disposable laboratory items - container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of m
Tender For supply of manual cock , model no rp 1/2, gas dh15r50, make kromschroder part no ks03152149 pc-100 or exactly equivalent in other makes like madas/honeywell/maxon and eclipse. connection thread type: rp internal thread (parallel internal gas thread) iso 7-1 standard. size / nominal diameter: 1/2 (rp 1/2) (also designated dh 15r50, dn 15) push-to-test operation: press the button to apply pressure to the gauge and release to isolate. material: brass (nickel-plated). maximum allowable pressure (pu max): 5 bar ( 70 psi) for gas and air. temperature range: -20 degree c to +60 degree c . weight: approx. 0.256 kg [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of growler tester suitable for 6fra6068 three phase rotor, dual magnetization yoke with standard accessories. one set consisting of 05 items - (1) thermacol moulded carry case-1 no (2) astm test block-1 no (3) pie gauge - 1 no (4) puffer bulb -1 no. (5) dry magnetic powder black water base - 1 kg. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of design engineering inspection testing supply of flp motor driven hydraulic variable suction cng booster compressor with canopy having avg flow capacity of 400 scmh , lcv unloading post with coriolis mass flow meter 4 inch dial size pressure gauge , installation and commissioning at site along with field performance acceptance test , operation charges for 1st year i e during warranty period , comprehenesive maintenance charges for 1st year after completion of warranty period , comprehensive maintenance charges for 2nd year i e after completion of 1st year post warranty , comprehensive maintenance charges for 3rd year i e after the completion of 2nd year post warranty , comprehensive maintenance charges for 4th year i e after the completion of 3rd year post warranty