Web Analytics Made Easy - StatCounter

Water Analyzer Tenders

Get complete information related to latest Water Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40561635 Due date: 23 Jul, 202523 Jul, 2025 50.50 Lacs
Tender For corrigendum : nib for supply of instrument automic absorption spectrometer with integrated graphite furnace, p.m. 2.5 sampler, integrated sound level meter, double beam uv/vis spectrophotometer, gps, sulphur dioxide analyser, oxides of nitrogen analyser, independent gaseous pollutant sampler, pen type tds meter, pen type ph meter, pm 10 analyzer, water analyzer kit for field studies, flame photometer and pen type conductivity meter for the laboratory of environmental science department, mgsu under the pm-usha scheme.

CTN :40955282 Due date: 18 Aug, 202518 Aug, 2025 NA
Tender For item wise procurement and supply of laboratory items for a period of 12 months - equipments, digital turbidity meter/ nephelometer -(a).parameter range- 0 to 200 & 200 to 1000 ntu*. (b). readability - 0.1 ntu & 1.0 ntu. ( c). accuracy - 3% of range. (d). repeatability - 2% of range. (e). light source - tungsten halogen lamp. (f). detector - photo diode. (g). data presentation - 31/2 digit 7 segment led of 12.7 mm height. (h). accessories - matched test tubes- 5 nos. (i). useful for determination of sulphate, phosphate, chloride, zn, ag, etc. by astm procedure. (j). extendable for measurement of inhibition growth of semantic microbial agent .brands-systronic,techlab,elko, digital conductivity meter with conductivity cell type cc-03b. (a). conductivity range : 0 to 20,200 m s*, to 2,20 & 200 m s*, (b) readability : 0.05% of range, (c) accuracy ; +_1% of range, (d) repeatability;+_1% of range, (e) data presentation: 31/2 digit 7 segment led of 12.7 mm height, (f) operating frequency: 1000hz, (g) temp. compensation: 0 to 500 c manual, (h) cell constant: 0.05, 0.1 or 1.0 (selectable), (i) out put: 20mv full scale into 10kz resistive impedance, (j) accessories: cell stand with cell holding clip.brands-systronic,techlab,elko, digital ph meter with combined ph electrode type cl - 51b (a). ph range: 0 to 14, +_1999 emf (mv), (b) readability : 0.1 ph, 1emf(mv), (c) accuracy ; +_0.01 ph, +_1 emf (mv), (d) repeatability;+_0.01 ph, +_1 emf, (e) temp. compensation: 0 to 1000 c manual, (f) data presentation: 31/2 digit 7 segment led of 12.7 mm height with polarity, (g) accessories: stand with electrode holding clamp, buffer tablets and polythine bottle, (h) physical dimensions: size 295 x 165 x 140 & weight - approximate 3, (i) manual 2 point calibration for ph, digital salinity meter (micro processor based water analyzer with magnetic stirrer), (a) measures directly ph, emf, temperature, electrolyte conductivity(ec), total dissolved solid (tds), dissolve oxygen (do), sanitary colorimeter (abs & %t) and turbidity in water sample one at a time. (b) data presentation: 2 lines 16 character dot matrix lcd modules, (c) light weight portable and easy to carry on field, (d) operates on rechargeable battery & mains supply, (e) ph: range- 0-14, readability- 0.001, accuracy - +_0.001,repeatability - +_0.1, (f) emf (mv): range- +_1999,9, readability - 0.1, accuracy - +_0.1, repeatability- +_0.1, (g) temp: range - 0-1000 c, readability - +_0.1, accuracy - +_0.5, repeatability - +_0.1, (h) ec; : range - 0-200 ms (5 ranges), readability - 0.05% of range, accuracy - +_0.1 of range, repeatability - +_0.5% of range, (i) tds: range- 0 to 100 ppt 5 range with pds factor 0.5, readability - +_0.05% of range, accuracy - +_1% of range, repeatability - +_0.5% of range, (j) do: range - 0-20, readability - 0.1, accuracy - +_0.1, repeatability - +_0.1 (k) colorimeter: range- +_2 abs & 0 to 100% t, readability - 0.001, accuracy - +_0.05 abs, repeatability - +_0.01 abs, (l) turbidity: range - 0 to 100 ntu, readability - 0.001, accuracy - +_2%, repeatability - +_0.1% (m) salinity ranger: 0 to 40 ppt, accuracy - +_1%, temp, compensation - 0 to 500c, sensor- ise (chloride) & re- bnc, (n) accessories: ce, dip type conductivity cell of 1.0 cell constant, do probe, thermo probe, magnetic stirrer, mains operated electromagnetic stirrer gi 631, stirring capsules, electrode stand with holding clamp, gas permeable membranes and 10mm & 30mm test tubes., zerological water bath superior quality(manufactures specification should be uploaded), ph meter (pocket type), brands-tamp,techlab,scientix, tds meter (pocket type) ,brands-tamp,techlab,scientix, magnetic stirrer superior quality (manufactures specification should be uploaded), heating mantle superior quality (manufactures specification should be uploaded), rainguage with measuring cylinder superior quality (manufactures specification should be uploaded), water purifier (dew drops)superior quali

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso
 Loading, Please wait...

Connect us via What's Up