Web Analytics Made Easy - StatCounter

Water Block Tenders

Get complete information related to latest Water Block Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Block Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Block Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45732688 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For nonond block: sampla panchayat: nonand dist.: rohtak annual maintenance work for water supply - 20 hp horizontal motor rewinding copper wire, material kit with labour and scrap old wire / job work for rewinding/repair of 20 hp cw motor with material, labour charges, motor opening and fitting, carriage charges and replacement of 2 nos. bearings and fitting charges and less then old material at w/w nonand

State Government

CTN :45621861 Due date: 08 Jul, 202608 Jul, 2026 24.72 Lacs
Tender For corrigendum : special repair of existing s and s tank and recoupment of filter media including washing of existing filter media etc for water supply scheme biroke kalan block budhlada district mansa

Central Government/Public Sector

CTN :45427822 Due date: 07 Jul, 202607 Jul, 2026 39.97 Lacs
Tender For corrigendum : ca no. ge af no.1 / gur-38 / 2026-27 repair/ maintenance of external water supply, fire fighting system, fire alarm and other connected works in sekhon vihar under ge (af) gurgaon no.01

State Government

CTN :45732725 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For baldhan khurd, group of 1 no. of habitations annual mtc.works for water supply - hiring of jeep / hiring of jeep on rent for office use under phed division excluding diesel and incl. day to day maintenance i.e insurance charges, repair monthly charges for the period of 01.06.2026 to 15.06.2026 at division office kosli

CTN :45292709 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For bid to ras supply of coducter complete set with all accessories , pvc armoured cable 16 sqmm 4 core make havells comma finolex comma polycab , mcb box 8 way make l and t comma usha comma cg , recess mounting light 2 x 2 make bajaj comma crompton comma philips comma cg , ceiling fan 1200 mm sweep make bajaj comma usha comma cg comma khaitan , ms hook 12mm rod for fan , led tube light 20 watt 4ft complete make bajaj comma usha , led bulb 10 watt make philips comma anchor comma bajaj , exhaust fan 300 mm make philips comma anchor comma bajaj , mcb 63 amp make philips comma anchor comma bajaj , mcb 40 amp make philips comma anchor comma bajaj , mcb 5 to 30 amp make philips comma anchor comma bajaj , mcb 16 amp make philips comma anchor comma bajaj , cooler motor 6100rpm desert cooler 450mm make philips comma usha comma bajaj , desert cooler motor make philips comma usha comma bajaj , desert cooler water pump make philips comma usha comma bajaj , ceiling rose , pvc cable xlpe 25 sqmm 4 core make havells comma finolex comma polycab , led tube light fitting 10 watt 2 ft complete make bajaj comma usha , switch socket combination 15 amp make anchor comma bajaj , switch socket combination 5 amp make anchor comma bajaj , desert cooler 6100rpm make philips comma usha comma bajaj , switch 15 amp modular type make bajaj comma philips comma siemens comma anchor comma equivalent isi marked , bulk head fitting make philips comma bajaj , pvc swithc board 7 inch x 4 inch make anchor comma bajaj , pvc swithc board 10 inch x4 inch make anchor comma bajaj , socket 15 amp make anchor comma bajaj , flood light 100w make philips comma bajaj , security light 100w make philips comma bajaj , ro membrane for 1000lph make adelino comma leo comma cg comma kirloskar , fuel filter for 62 point 5 kva make kirloskar , oil filter for 62 point 5 kva make kirloskar , fan belt for 62 point 5 kva make kirloskar , oil temp guage for 62 point 5 kva make kirloskar , oil pressuer guage for 62 point 5 kva make kirloskar , exhaust fan for 62 point 5 kva make kirloskar , fuel guage for 62 point 5 kva make kirloskar , battery 12 v150 ah make exide comma amaron , engine oil make castrol , fuel filter for 30 kva make kirloskar , oil filter for 30 kva make kirloskar , fan belt for 30 kva make kirloskar , air filter paper type for 30 kva make kirloskar , panel box repair make kirloskar , alternator winding 62 point 5kva make kirloskar , router winding 62 point 5kva make kirloskar , excider winding 62 point 5kva make kirloskar , avr card make kirloskar , diode make kirloskar , starter motor repair make kirloskar , flywheel ring gear make kirloskar , fuel pipe make kirloskar , alternator winding 30kva make kirloskar , rotor winding 30kva make kirloskar , exciter winding 30kva make kirloskar , change over switch 100amp , submersible pump rewinding , change over switch 64amp

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

State Government

CTN :45646202 Due date: 02 Jul, 202602 Jul, 2026 2.14 Lacs
Tender For corrigendum : repair of damaged water supply line, to hpsebl colony at u/s sandhasu, including repair maintenance of hpsebl residential qtrs at sandhasu colony

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

corporations/Associations/Others

CTN :45734071 Due date: 14 Jul, 202614 Jul, 2026 2.50 Lacs
Tender For maintenance of water supply works at ward 1 to 24 minipower pump hand pumps and other repair of vandavasi municipality
 Loading, Please wait...

Connect us via What's Up