Tender For supply and installation and commissioning of spm analyzer - supply, installtion & commossioning of spm analyzer with tuv. as per specifications, the system should have the below features as desired by cpcb.a) the spm analyzer should have continuous quality check for zero and spa point, prferably without human intervention to ensure continuous daya validity and credibility. (please refer guidelines for continuous emission monitoring system july 2017 page 8/100)b) the system should have feature of automatic range setup.c) the system does not required manual adjustment and should operate without any human intervention.d) the system should have autotic drift compensation.e) the system doen not have optical windows to be cleaned.f) the system should not required any alignment for smooth operation.g) the system doen not have any effect of vibrations on the system accuracy and readings.h) the system should have tuv with qal (en15267 parts 1 to 3) with appropriate certification range as per cpcb guidelines.measurement principle: inductive electrificationmeasurement objects: solid particles in a gas flowparticle size : 0.3 um or largermeasurement range: approx 0.1 mg/m3 to 1 kg/m3probe length: as per requirement (standard 500,750,1000,1500,2000 mm)probe dia: 10 mm, max temperature: upto 300 degree c. (optional upto 700 degre c)max pressure: 3 bargas velocity: min 4 m/sresponse time: less than 1 secondself zero span check: yessignal averaging: adjustable 0-300 seondoutput signals: isolated 4-20 ma serial communicaiton rs-485 modbus - two spdt relays:5a-24 vac/dcambient temperature: 20 to +60 degree chumidity: 95% rh (non- condensing)vibration: 5 m/s2 or lessprobe: ss316 linsulation of probe: peekenclosure: aluminmb alloypower supply: 230 vac, 15 vac, 24 vdcpower consumption: 3 wprotection: ip65certification: tuv with qal1, chief engineer
Tender For supply of servicing of fe,dcp,9kg , servicing of fe,dcp,25kg , servicing of fe,dcp,75kg , servicing of fe,co2,4.5kg , servicing of fe,co,2kg , refilling cartraidge 10 09 kg dcp , refilling cartraidge 25 kg dcp , refilling cartraidge 75 kg dcp , refilling 02 kg co2 cylinder , refilling 4.5 kg co2 cylinder , hydrotesting of fire hose , supply hose pipe 09 10 kg dcp , supply hose pipe 25 50 kg dcp , supply hose pipe 75 kg dcp , supply hose pipe 4.5 kg co2 , safety pin 09 10 kg dcp , safety pin 4.5 kg dcp , supply of 02 kg co2 cartraidge , supply of 200 gram co2 cartraidge , hydrant monitor servicing , servicing of two railway siding sprinkler , servicing of tank sprinkler at height , refilling of scaba cylinder , servicing of scaba cylinder , testing of foam pourer , testing of hand operated siren , servicing of safety shower , greasing servicing of valve , supply of nozzle 10 kg dcp , supply of nozzle 25 kg dcp , supply of nozzle 75 kg dcp , servicing of mefg tank dyke , supply filling of nitrogen , suuply filling of foam , supply filling of mineral water , cleaning of strainer , maintenance of hose box , supply of hose box , supply of dcp powder , supply of dcp cap asembely , supply of dcp fe cap washer , supply of lead seal , supply of connecting tube for trolly fe , supply of hydrant couping washer , supply of hydrant sheet washer , supply of hydrant operating wheel , supply of hydrant pvc blank cap , supply of co2 hose pipe , supply of co2 horn , supply of antistatic harness , supply of hose box ribbon , supply of hose box glass , supply of fe instruction sticker , supply of co2 fe operating wheel , supply of co2 fe carrying handle , supply of first aid kit , supply of wind indicator stand , supply of wind shock red n white , supply of siphone tube , fire extinguisher hydrotest upto 10 kg , fire extinguisher hydrotest upto 25 kg , fire extinguisher hydrotest upto 75 kg , supply of watercumfoammonitor pick up tube , gas detector calibration , servicing of h hvlrm , s i foam trolly level pipe , s i mefg pick up tube , hose box key , supply hydrant lugs , fire extinguisher paint upto 10 kg , fire extinguisher paint upto 25 kg , fire extinguisher paint upto 75 kg , supply of fire bucket stand , supply of fire bucket 09 ltr as per is , safety shoes , safety helmet , lifeline revalidation per line , supply of hhmd , o2 sensor replacement , new multi gas detectot honeywell , supply of fire hose b type 63 dia, 15 mtr l , safety googles , hydrant valve with gunmetal coupling
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi