Tender For corrigendum : inj. oral meglu and sod diatrizoaten flavoured ionic, water soluble , oral contrast agent for gi tract for ct combination of diatrizoate sodium and diatrizoate meglumine iodine content 365 375mg/ml in 30ml qty- 300/-
Tender For tender for supply of m soil investigation : : -obalisation of necessary eqpt and man power to the project site and dismantling of the same of completion of field work from the site , provision of two bore hole of 150 mm dia in any type of soil upto max 10 mtr or upto refusal n 100 whichever meet first conducting standard penetration test as per is 2131 1981 reaffirmed 2016 test shall be made at not more than 1 50 mtr interval or on change of strata whichever is less , conducting following lab test on bore collected soil sample i direct triaxial shear test ii grain distribution curves & pattern in bore holes iii bulk density iv natural moisture content v dry density vi water table vii specific gravity viii atterberg limit ix hydrometer analysis x liquid & plastic limit xi swelling index , collection of lab test data calculation of gross and net safe bearing capacity and preparation of report on minimum 80 gsm a4 size white paper duly spiral bound in quintuplet duly vetted by any iit nit vetting shall not be in the personal capacity of the professor for foundation report shall recommend type of foundation and sizes at different depths below ngl including size gross and net safe bearing capacity , i photographic record of geo exploration as well as testing shall also part of the report ii recommendation as regards possibility of liquefaction of soil in case of saturated or partially saturated loose uncompacted sandy soil iii swelling index and swelling pressure in respect of black cotton soil and its depth layer if any iv depth of gr water table gwt in peak mansoon lowest and peak summer highest after correlation of result with seasonal of water table in the station v recommendation for filling under floors vi rl of ground level foundation level with ref to a bm should invariably be mentioned in the soil investigation report
Tender For auction sale of depot non ferrous scrap - scrap aluminium water tank with attachment of ferrous and rubber of sort and sizes. the approx metal content is as under - aluminium- 88%, ferrous-4%, dust sedement rubber hose pipe etc. 8%. note 1- loading by purchaser, 2- cutting not allowed 3- delivery not allowed against part payment. location- lying at line no. -09 in front of nf ward
Tender For supply of 1) atterberg limits (is: 9259-1979). plastic limit (pl) the water content at which the soil changes from a semi-solid to a plastic state.2)cube testing machine digital 1500 kn. digital cube testing machine with self calibration is a precision laboratory instrument used to test the compressive strength of concrete cubes. (is 14858:2000) equipment should be as per is specification.3)sieve analysis gi sieves 45 cm dia [40 mm, 20mm, 10mm,12.5 mm, 6.3 mm. aggregate sieve analysis, used to determine the particle size distribution of coarse and fine aggregate.4)specific gravity bottle of 1 kg capacity. a specific gravity bottle, determine the density of liquids or solids by measuring their mass and volume5)universal automatic mechanical compaction machine universal mechanical compaction machine is motorized lab device used to compact soil samples (is:10074)6)wet and dry sieve analysis[40mm,20mm,10mm,4.75mm,2mm,600mic.,425mic,212mic,75mic] wet and dry sieve analysis used to determine the particle size distribution of granular materials 45 cm dia ( is: 460 - 1962)7)distilled water plant. a distilled water plant, produce high-purity distilled wate. this pure water is essential for laboratory applications where contamination-free water8)heavy duty compaction equipment (is:9198 & is:10074) heavy duty modified proctor compaction test apparatus with moulds , used to compact soil samples in moulds of 2250cc and 1000cc with rammer
Tender For supply of lab equipments - vertical autoclave (q2) , microscopes - pathological and research as per is 4381, is 5204, is 4381, is 5204 (q3) , electro cautery machine , multipara monitor , ups 10kva , suction machine , sphygnometer verticle stand , sterilization chamber , vein veiwing device , anatomy structure model lunges , anatomy structure model heart , anatomy structure model pelvis , anatomy structure model brain , anatomy structure model urology , anatomy structure model torso , anatomy structure model larynx , anatomy structure model male and fenale pelvis set , anatomy structure model skeleton , anatomy structure model muscled arm and legs , anatomy structure model skull and brain , anatomy structure model muscled , water bath , ph meter , waterdistillation , hot air oven
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr