Web Analytics Made Easy - StatCounter

Water Drainage Tenders

Get complete information related to latest Water Drainage Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Drainage Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Drainage Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45326789 Due date: 03 Jun, 202603 Jun, 2026 1.99 Lacs
Tender For annual maintenance estimate of roads, water supply, seweraage and storm water drainage scheme in sector-19, rewari for the year 2026-2027

State Government

CTN :45349832 Due date: 11 Jun, 202611 Jun, 2026 9.67 Crore
Tender For construction of regulator on left bank at rd 50m of mungeshpur drain off take point at rd 34500m of supplementary drain along providing and fixing five nos. gates and gearing system on left bank at rd 50m

Central Government/Public Sector

CTN :45332585 Due date: 25 Jun, 202625 Jun, 2026 2.24 Crore
Tender For sitc of vrv type ac - 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp sitc , fp mcb 63 amp sitc , fp mcb 40 amp sitc , sp and n distribution board 12 way hvac idu , dp mcb 32 amp sitc , sp mcb 6 or 10 amp sitc , sfu 100a tpn at main switch board sitc , chemical earth electrode earthing arrangement sitc , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system

State Government

CTN :45308361 Due date: 03 Jun, 202603 Jun, 2026 56.76 Lacs
Tender For construction of borewell (04 nos) for rain water drainage in main mandi yard kums bikaner (grain)

Central Government/Public Sector

CTN :45345554 Due date: 06 Jun, 202606 Jun, 2026 16.50 Lacs
Tender For supply of 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp , sitc of 5 star 3 ton cassette a c , copper pipe refrigerant piping for 1.5 or 2 tr , interconnecting standard wire cable , drain pipe , ms stand

Central Government/Public Sector

CTN :45336407 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For supply, installation, wiring, commissioning and testing of 1.8 ton inverter 5/3 star rated wall mounted split ac along with 1/2 and 1/4 copper pipe minimum 12 ft and drain pipe with foam insulation over copper pipe with suitable size of pvc cable and connectors conforming to is 732: 2019 or latest for wiring. accepted make of ac jare blue star, hitachi, panasonic, or equivalent at new bogie conference room along with complete wiring with 1.5 sqmm and 2.5 sqmm copper pvc cable as per site requirement and shall be done with suitable wiring and protection system protected with 40a 3/4 pole residual current circuit breaker of leakage current 30 ma and overload protection with mcb conforming to is:12640 part 2 or latest and iec 60898 part 1 or latest respectively and all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 land indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirementshall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. [ warranty period: 30 months after the date of delivery ] ]

corporations/Associations/Others

CTN :45321740 Due date: 05 Jun, 202605 Jun, 2026 26.20 Lacs
Tender For strengthening of storm water drainage system for smooth disposal of rain water at various locations in sector 43 chandigarh.

Central Government/Public Sector

CTN :45342088 Due date: 16 Jun, 202616 Jun, 2026 26.80 Lacs
Tender For repair/maint of drain/culvert/garden walls/gate including cleaning of area drainage system at technical and residential area of deal under ge (i) r and d dehradun

Central Government/Public Sector

CTN :44994611 Due date: 30 May, 202630 May, 2026 23.68 Lacs
Tender For corrigendum : provn of rain water recharge pit and provn of rain water harvesting pond at certain locations and special repair to rain water drainage in the premises of aps kamraj under ge(south) bangalore.

Central Government And Public Sector

CTN :45332724 Due date: 08 Jun, 202608 Jun, 2026 5.37 Lacs
Tender For supply of supply of 3 tr non inverter ductable ac as per bsnl specifications , itc of 3 tr non inverter ductable ac as per bsnl specifications , supply and fixing copper piping of 0.75 inch with nitrite foam insulation as required , supply and fixing copper piping of 0.625 inch with nitrite foam insulation as required , supply and laying 4 core 4 sq mm pvc insulated copper cable as required. , supply and laying 4 core 2.5 sq mm pvc insulated copper cable as required. , supply and fixing 1 inch dia pvc pipe for water drainage as required , s fixing ms structure of suitable size as required , making covering of extra oper space of leakge as required , supply and fixing 8way double door 4 and 24 nos tpn mcb db , supply and fixing 5a to 32 a tpn c curve mcb in extg db as required , supply and fixing 60a four pole isolator in extg db as required , supply and fixing single ploe blanking plates , supply and fixing 8 swg gi wire for loop earthing as required , supply and fixing 150mm x 50mm x 1.5mm perforated ms cable tray
 Loading, Please wait...

Connect us via What's Up