Get complete information related to latest Water Foam Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Foam Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Foam Monitor Tenders.
Tender For maintenance of electrical installation and fans i/c compound lights and repair maintenance of pump sets and electric sub station at jija bai, i.t.i for women, sirifort, new delhi during the year 2025-26 (sh- supply, installation, testing and commissioning of dbs panel mounted fire protection devices)
Tender For repair / maint of diesel generator set amf panel, existing earthing, lighting conductor, fire alarm system and connected works at af stn bihta.
Tender For supply of dsitc of 40kw pv solar plant at fire station building , dsitc of 10kw pv solar plant at power house building. , supply, installation, testing and commissioning of acdb panel. , net metering arrangement and liaising charges with dept of power nagaland. , supply of 3.5 x 185 sq.mm xlpe insulated armoured , laying of one number xlpe armoured power cable in open duct above 95 sq. mm and upto 185 sq. mm , laying of one number xlpe armoured power cable in open duct upto 35 sq. mm , laying and fixing of one number xlpe armoured power cable in cable tray above 95 sq. mm and upto 185 sq. mm , laying and fixing of one number xlpe armoured power cable in cable tray upto 35 sq. mm clamped with 1mm thick shaddle. , laying of one number xlpe armoured power cable in the existing pipe as required above 95 sq. mm and upto 185 sq. mm , supplying and laying of 120 mm dia dwc hdpe pipe direct in ground. , supplying and making end termination 3.5 x 185 sq.mm , supplying and making end termination 3.5 x 35 sq.mm , providing, laying and fixing of 100 mm dia gi pipe , sitc of smart rfid based electronic cable marker 220 mm dia , operation and aicmc 1st year after dlp , operation and aicmc 2nd year after dlp. , operation and aicmc 3rd year after dlp , operation and aicmc 4th year after dlp , operation and aicmc 5th year after dlp
Tender For bid to ras bid to ras armo 2025 27 sh operation and maintenance of hvac system at split at goa airport - manpower for operation and day to day maintenance , camc 4nos x 600 tr chiller , camc 1no x 400 tr chiller , camc anciliary equipments of hvac system , treatment and analysis of hvac condensor water , treatment and analysis of hvac chilled water , supply and replacement of chiller compressor lube oil for carrier make , supply and replacement of chiller compressor lube oil for blue star make , replacement of old worn out ahu air filter with new filter , cmc of ahu fire smoke damper, control panel, actuator , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-500 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-400 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-350 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-300 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-150 mm dia valve , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 24 swg , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 22 swg , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 20 swg , supply and fixing 50 mm thickness closed cell nitrile rubber with insulation provided with uv protected aluminium based cladding with cold setting adhesive on exposed outdoor ducting , supply and fixing 50 mm thickness closed cell nitrile rubber with insulation with factory laminated aluminium foil by applying suitable cold setting adhesive on indoor ducting above false ceiling , cmc of existing uvgi ultra violet germicidal irradiation system provided inside ahu exluding uv lamp reflector and uv ballast. , supply of uv lamp for existing uvgi provided inside ahu , supply of reflector for existing uvgi provided inside ahu , supply of uv ballast for existing uvgi provided inside ahu , cmc of car parking ventilation system installed at mlcp including axial flow type jet fans , cmc of window split type airconditioners cassette type of all makes of 1 point 5 ton 2 ton capacity with single phase supply at different locations including providing for first year , cmc of window split type airconditioners cassette type of all makes of 1 point 5 ton 2 ton capacity with single phase supply at different locations when required for second year , comprehensive maintenance contract of split multi split type cassette typetower type airconditioners of all makes of 3 ton capcity with 3 phase supply etc as and when required for first year , comprehensive maintenance contract of split multisplit type cassette type tower type airconditioners of all makes of 3 ton capcity with 3 phase supply etc as and when required for second year , cmc for vrf system indoor unit varying from 1 ton - 2 ton installed in new admin block , cmc for vrf system indoor unit varying from 3tr installed in pre security area , cmc for vrf system indoor unit varying from 4tr installed in pre security area , cmc for vrf system indoor unit varying from 4tr installed in 1st floor mlcp cisf portion , cmc for vrf system indoor unit varying from 4tr installed in 2nd floor mlcp, aai offices , cmc for vrf system indoor unit varying from 2 ton and cassette unit of 3 ton installed in apron control room. , comprehensive maintenance contract for vrv variable refrigerant volume system consisting of 03 nos of 3point2 tr cassette ac indoor unit, including all related accessories installed in aocc room , comprehensive maintenance contract for vrv variable refrigerant volume system consisting of12 nos outdoor units of 17point7kw each rating, installed in present dsha , comprehensive main
Tender For tender for supply of gas based suppression system 140 kg seamless cylinders , supply of fluoro ketone gas fk 1230 , centralized master cylinder kit comprising primary cylinder accessories electric cum manual actuator , centralized slave cylinder kit comprising secondary cylinder accessories pressure operated control head , centralized tertiary cylinder kit comprising tertiary cylinder accessories pressure operated control head , supplying and installation of central following accessories in the existing gas supression system manifold check valve 2 inches , supplying and installation of central following accessories in the existing gas supression system discharge nozzle , supplying and installation of central following accessories in the existing gas supression system cylinder strap for 140 lt is cylinder , supplying and installation of central following accessories in the existing gas supression system manifold discharge pressure switch , supplying installation testing and commissioning of two zone addressable gas release panel facility manual abort , ul listed manual release switch for gas release (mcp green) , ul listed abort switch for gas release (mcp yellow) , ul listed sounder cum strobe complete as required , sitc of suitable size m s seamless pipes as per astm 106 gr b schedule 40 manifold fabricated from seamless pipe pipe s m s seamless to astm a 106 sch 80 , sitc of suitable size m s seamless pipes as per astm 106 gr b schedule 40 piping fittings and supports etc pipe (s) m s seamless to astm a 106 sch 40 , supplying installation testing and commissioning of intelligent analog addressable type photoelectric type smoke detector complete with dual led , hard addressable having rotary decade address switches from 01 to 99 , supplying installation testing and commissioning of remote indicator complete with connection etc as required , supplying installation testing and commissioning of intelligent analog addressable type manual call point having surface or flush mounting option fully compliant to en54 , supplying installation testing and commissioning of addressable type loop powered hooter complete with mounting base , supplying installation testing and commissioning of addressable type fault isolator for isolating shorted , de-linked and loose circuits , supply and fixing pvc insulated pvc sheathed stranded armoured frls 4x1.5 sq mm , supply and fixing pvc insulated pvc sheathed stranded armoured frls 2x1.5 sq mm , supply and fixing of tripod of suitable size with junction box compete with fixing on floor complete , supplying installation testing and commissioning of monitor module to integrate other device i e vesda etc with fire alarm panel , supplying installation testing and commissioning of control module fro ahu tripping , supplying installation testing and commissioning of micro processor based 2 wire fault tolerant networkable type fire alarm or detection 1 loop control panel , supply , installation , testing and commissioning of laser based absolute smoke detection vesda system coverage up to 5000 square-feet , supply and installation of trunk adaptor for capillary points suitable for vesda system , supply and installation of capillary sampling connector for capillary tubes suitable for vesda system , supply and installation of capillary tube for sample points 5.2mm id 8mm od per metre suitable for vesda system , supplying and installation of sampling point for capillary tube end suitable for vesda system , supply and installation of sampling point label red suitable for vesda system etc complete , supplying and laying of u-pvc c-pvc smooth bore aspiration tube of size (21mm internal dia and 25mm external dia) suitable for vesda system
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For providing of operation and maintenance of fire alarm system - emergency repair/repl of fire alarm two loop panel system at mbu kasimedu chennai
Tender For maintenance of electrical installation and fans, repair maintenance of p/set, diesel generator set, sub-station, lift, owc machine, stac/wtac, fire alarm and fire fighting downcomer system at rak college of nursing, lajpat nagar, new delhi during 2025-26. (sh- routine maintenance of kirloskar make diesel generator set 82.5 kva with amf panel).
Tender For construction of administrative block for shq, bsf, radhabari, siliguri under north bengal frontier including internal water supply, sanitary installations, and electrical installations (i.e. iei, fan & fittings, lt panel / feeder pillar, fire fighting system, audio video conferencing, lan & cc tv etc.)