Web Analytics Made Easy - StatCounter

Water Heater Tenders

Get complete information related to latest Water Heater Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Heater Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Heater Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45727827 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For providing and fixing of water heater element of 2 k.w. heating capacity, repairing of steel iron

Central Government/Public Sector

CTN :45733902 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For repair and maintenance of summer appliances ceiling fans desert coolers water coolers refrigerators winter appliances, electric geyser solar water heater and other equipments at mil stn dappar under age(i) dappar

State Government

CTN :45735150 Due date: 06 Jul, 202606 Jul, 2026 7.01 Lacs
Tender For supply, installation, testing and commissioning of solar water heaters on the terrace of newly constructed first floor of boys hostel building no. 5

CTN :45560058 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : tender for supply of clamp meter , 5 gallon compressor oil tin , core for filter drier , filter drier core rpe48bd , relay base type rxze2m114 , relay 24v dc 4 co rxm4ab2bd , single core 40 mmsqlfh cable , ss washer 125 , screw driver set , ss 304 tubing , pilot tube fitting , filter drier replacement core , potentiometer shaft , relay , store room thermostat , piston set , valve plate set , pocket for temp switch , gasket , therm injection valve , defrost heater element tat 30 , shut off valve , shut off valve , shut off valve , temperature transmitter pt 10 , solenoid valve on oil return line , condensers of chilled water units ac , thermometer discharge line , thermometer cwinlet , flex metal hose , oil heater , therm injection valve , needle valve , gauge oil pressure , feeler pocked , stop valve , stop valve , power contactor 115 vac , air contactor , chilled water pump of air conditioning plant , fuse 500v , relay 24vdc , rc module , auto controller , antifreeze thermostat , fuse switch , fuse switch , sight glass set , current meter , pilot lamp , valve relief , metaflex coupling api 671

CTN :45711088 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For spare parts for scania veh - ventilation glass v part no 206415, door glass part no 206957, door handle, outer v part no 227855, door handle, outer h part no 227856, lock v part no 1864792, control v part no 187721, control h part no 187722, ball part no 236177, side glass part no 256680, rear glass part no 256682, hydraulic pump part no 361453, wiper arm part no 1105172(255837), air nozzle part no 268387, air duct left part no 195669, air duct right part no 257104, fan motor(cab heater) part no 242395, closing plate lock part no 285093, window panes left part no 285070, adjusting angle connect part no 562579, nipple part no 562564, rubber protection part no 562608, nipple m8 part no 562617, pkv part no 562625, 28 spool control module part no 2530720477383(5626, selector valve part no 562631, hydraulic pipe part no 562648, switch part no 562656, motor part no 562464, extre man boom part no 562486, level indicator part no 562551, hydraulic pipe part no 562647, solenoid 24v part no 562520, rope guide roll rear part no 261389, bolt mc6s10 x 25 part no 809826, earth cable 430 mm part no 308080, safety valve part no 562626, solenoid valve part no 1115802(350127), junction box part no 583038, regulation arm / shock absorber part no 1104743

CTN :45722569 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of electric ceiling fan (v4) isi marked to is 374 , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 , exhaust fan pvc body 12" (300mm) sweep 230v, 50 hz , desert cooler bode size 48 inch (hight) , made from gi sheet

CTN :44978519 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : procurement of “building spares and outdoor supply source. - geyser assembly 6-hole, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, geyser coil 2kw, geyser coil, 2 kw, 230 vac, 25 ltrs capacity, thermostat for geyser type-9-inch length, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, electric geyser neon indicator light red, 240v ac red indicator light pilot lamp, neon bulb, electric geyser neon indicator light green, 240v ac green indicator light pilot lamp, neon bulb, gyser model: ap-25v, cap:25ltrs, racold,crompton arno neo 25-l 5 star rated storage water heater (geyser) with advanced 3 level safetybrand cromptoncapacity 25 litres power source corded electricproduct dimensions 337.5w x 54.2h cmspecial feature auto restart, fast heating, geyser safety valve, for, 25 litre capacity geysers, make: crompton., cut out relay for geyser- type 9-inch, supply voltage-250v ac required for, 25 litre capacity geysers, make: crompton, ceiling fan, with copper winding coilnumber of blades-3, power consumption-52w, motor speed-380 rpm, design type-economy, type-ceiling fan, bee star rating-1, body material-aluminium, colour-white, 2 years company warranty, make-havells, crompton, bajaj, usha., portable type extension cable reel, without cable, portable i.e. lift & carryextension cable reel, heavy gaugetubular frame, sheet steel roller and al. discs with 2nos. m/c outletsocket 20a 3pin. reel capable of loading 50mtrs. 3core x 2.5mm.sq.pvc/pvc round sheathed flexible cable. (without cable)., power extension board - rating -15 amp, single phase extension board with 4core 2.5 sq.mm pvc insulated flexible cable (30 meter)component to be included in the board as bellow:1. 25a 2-pole mcb and 25a 2-pole rccb at incoming.3. 01 no s 1 phase 15a industrial socket with plug top and individual switch circuit4. 03 no s 1 phase 15a socket with individual switch circuit, industrial type extension box, fabricated from 16swg crcasheet of size 350mm x 250mm x 250mm. tower type powdercoated in deep orange shade gasketed doors conforming toip 55 and with the following components duly wired: -incomer: mcb and indication lampoutgoing: 4 no s f 10a socket & plug top each individuallycontrolled by a 10a dp rotary switch.

CTN :45716111 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For providing of custom bid for services - fabrication and installation of solar water heater pipe line

CTN :45635667 Due date: 03 Jul, 202603 Jul, 2026 6.08 Lacs
Tender For corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , household refrigerating appliances as per is 17550 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , washing machine - domestic purpose (q2)

CTN :45715657 Due date: 15 Jul, 202615 Jul, 2026 17.38 Lacs
Tender For tender for supply of erection and fabrication work b c c - juice/water scale ke weight channel bed mein se gale/kamzor channel ko kaatkar hatana. poorvanusar naya banakar lagana evam trial dena. , juice weighing scale ke filling tank ke rods ki kamzor/gali guides ko naya banakar lagana. , juice. maceration water evam final molasses ke weighing scale tank ke gale/kamzor bottom cone ko kaatkar purane anusar naya bottom cone lagana va poorn trial dena. , juice weighing system ke measured juice receiving tank ki gali/kamzor bottom evam side plates ko kaatkar hatana evam nirdeshanusar purani/nai plate lagakar leak.proof trial dena. , raw juice pump par lage catcher ko kaatkar hatana tatha naya catcher fabricate kar yathasthan lagakar samast connection poorv ki bhanti karna evam leak.proof trial dena. , pan. quad body evam vapour line juice heaters ki hydraulic testing ke liye inlet evam outlet ke vapour pipes mein cutting karke plate ke blind weld karna tatha hydraulic uparant blind kaatkar hatana evam vapour pipe ko punah andar va bahar se leak.proof weld karna. , semi kestner. vapour cell. quad body juice heater. vapour line juice heater ke condensate bottles tatha syrup receiving bottles ke cells ko kaatkar ceiling baffle plate ke kamzor hisse. bottom plate ke kamzor hisse athva cell ke kamzor hisse ko badalkar condensate bottles/syrup receiving bottles ki vanchhit marammat kar jal bharav parikshan dena. , juice heater mein lage ayatakaar juice entry box ko dismantle karna. gale/kamzor charon nipples badalna. double beat valves ki fitting hetu dono flanges lagana. box ki marammat kar box fit karna evam double beat valve fit karke leak.proof parikshan dena. , sabhi juice heaters ki gali hui sampoorn partition plate ko kaatkar bahar nikalna va nai 8/10 mm plate lagakar gili hui ring ko leak.proof welding karna tatha lagi hui tubes ko bachakar santoshjanak trial dena. , juice heaters mein dono taraf partition plate ki kamzor m.s. strip ko dismantle karna. kate face par grinding kar nai 25 mm x 5 mm ki m.s. strip banakar lagana evam rubber fit karna. , juice sulphiter ke recovery tower ke gale/kamzor bottom cone ko kaatkar 10/12 mm moti m.s. plate se sample anusar naya cone fabricate kar yathasthan fit kar leak.proof welding karna. , juice sulphiter ke base ke charon side ke gale/kamzor horizontal beams ki vanchhit strengthening hetu unke andar 12 mm moti plate lagakar majbooti pradan karna. , juice/syrup sulphiter ke kamzor bottom cones evam top cones ko dismantle kar sample anusar naya banakar fit karna. tatha andar va bahar se leak.proof welding kar santoshjanak jal bharav evam trial dena. , syrup sulphiter ke tower ki gali/kamzor baffle plates/jaliyon ko bahar nikalna. vanchhit marammat kar yathasthan fit kar leak.proof trial dena. , syrup pump se syrup sulphiter tak dono pumps ki delivery ki dono lines ko neeche utarkar garam karke. bhali bhanti safai karna. gali hui pipe line badalkar valve. bend. nipple ityadi lagakar punah lines ko fit karna evam leak.proof trial dena. , syrup/juice sulphiter ke upar lage recovery tower ko utarkar gali shell ko nirdeshanusar nai/purani plate se shell taiyar kar fit karna evam tower ko punah yathasthan lagakar leak.proof trial dena. , juice/syrup sulphiter/clarifier ke kamzor shell ke kamzor bhag ko kaatkar hatana. nirdeshanusar nai/purani 10/12 mm plate se banakar yathasthan lagakar andar va bahar se leak.proof welding kar trial dena. , sulphur bhatti (juice/syrup) ke gale/kamzor secondary gas cooler ko kaatkar hatana. 10/12 mm moti plate se purane ke anusar naya cooler fabricate kar yathasthan fit kar samast connection poorv ki bhanti kar leak.proof gas trial dena. , sulphur bhatti station par juice/syrup hetu sthapit sulphur bhattiyon ke gas coolers ke gale/kamzor cooling pipes ko kaatkar hatana. purane anusar naye pipes taiyar kar poorv ki bhanti fit kar leak.proof trial dena. , sulphur bhattiyon ke gale gas headers ko kaatkar hatana. purane anusar naye headers taiyar kar lagana. , sulphu
 Loading, Please wait...

Connect us via What's Up