Web Analytics Made Easy - StatCounter

Water Jacket Tenders

Get complete information related to latest Water Jacket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Jacket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Jacket Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43205945 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For corrigendum : tender for supply of make- ird mechanalysis limited , ird544m - vibration sensor , inductive velocity , top exit , mil 2-pin connector , 42.52mv/mm/s , 10 hz - 1 khz sku - m97120 , make- ird mechanalysis limited , stud for vibration sensor item no 1 , mounting/grub screws , 1/4 inch-28unf male , m6 x 1 male sku - stud-m6 provides connection between vibration sensor and mounting pad , m/s ird mechanalysis limited , vibration sensor mounting pad mild steel blackodized for ird544m (60x60x16 mm) with m6 thread for item no 1 tapped sku - ms-pad-ird544m , make- m/s ird mechanalysis limited , vibration sensor cable assembly for item no 1 , signal cable teflon 3.5mm dia , ss conduit 5mm id , 15 meter length straight , 2 pin ms , shielded , spade lugs at free end sku - m601015spade lugs at free end carry following colour code- red core- signal live , black core- signal ground , green core- signal shield , make- ird mechanalysis limited , eddy current pickup set comprising of probe , driver and connecting cable for 9 meter system. constituents. , make- m/s ird mechanalysis limited ird8800 rack , 8 position , 5u sku - m88008 this is the bin and will accomodate ird8800 cards , make- ird mechanalysis limited ird8800 (8800) , m88250 (88250) casing vibration module , 2ch velometer input (mv /mm/sec) and 1ch key phasor input , api standard 670 compliant sku - m88250-dc ird8800 series module m88250 can work with all types of velocity output vibration sensors that provide mv/mm/sec output - like ird531 (4 mv/mm/sec) and ird544m (42.52 mv/mm /sec) , make- m/s ird mechanalysis limited , ird8800 (8800) , m88900 (88900) - speed module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88900-dc , input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcp-ip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , ird8800 (8800) , m88600 (88600) - eccentricity module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88600-dc input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcpip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , 35 mm din rail mount industrial grade power supply , 480 w , product- rps480 , 24 v dc output , dimension- 60 x 154 x 158.55 mm (w x h x d) , weight- 1050 gms , sku - rps480-24-ce supports 90 - 264 vac / 127 - 370 vdc power factor more than 0.95 full load over entire input range protection against short circuit , overload , overvoltage & over temperature cooling by free air convection ul 508 approved (e522848) efficiencies up to 93 % dc ok relay contact , make- ird mechanalysis limited , cabinet 1500 x 600 x 600 in mm , ip32 sku - cabinet-1500-600-600-ip32 , installation commissioning and calibration check of all supply sensor with unit at site

CTN :43225529 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For corrigendum : tender for supply of safety valve , mandatory kit 1000 hrs , high temp switch , shaft seal , o ring 5 , connecting rod bearing top & bottom , shim 0 50 3st cyl , copper washer safety valve , oil seal 25x15x7 , filter oil & collar , safety valve , hose , third stage air pressure gauge , first stage air pressure gauge , compressor motor coupling , solenoid valve 220v 1 , nut butterfly m8x1 25 , nut locking m18x1 5 crankshaft , connecting rod , connecting rod , connecting rod screw , main bearing bushing , crank shaft , seal 17x32x7 , coupling , three way solenoid valve , low iube oil pressure switch , pressure guage 0 10kg cm2 , contact manometer iii stage 0 4 , high temp switch , set of sv mounts , satety diaphiragm ee8884v 454480 , oil filter , valve with valve seat , o ring , i&ii stage cyl with water jacket , cylinder 3rd stage , cyl dia50 m c hp03 05 , cyl dla 100 m c ts05 07 , cylinder dia 60 , flat valve dia70 cyl ss02 03 , flat valve dia 100 cyl ss07 10 , valve flat 60 dia , ring soc dia 110 , connecting rod , inter cooler cover 1st stage , sol v assy 3 way , valve finger type dia50 cyl , valve plate dia 60 cylinder , valve finger type dia 70 cyl , valve finger type di , gaslet 0 8c ca , gasket 60 cyl to val fat 0 75 , slotted oil control ring , washer plain , sol v assy 2 , gasket fly end cover , pad tension adj air rec , element assy air filter ss02 , stud m8x40 , gasket end cover 0 2 , seal oil 52x35x7 , oil seal retainer , bush dist oil seal , stud m8x30 ek2 , stud m8x27 , stud m8x32 ek2 , ermeto m20xm24 , packing crankcase to cyl , guide dia25 piston , ring piston dia 25 3rd stage , ring c dia128 piston , shim ball pivot 0 05 , ball pivot bottom , shim water jacket iii stage cylinder 0 50 , stud m12x45 , shim 3rd stage cylinder head 0 30 , nut butterfly m8x1 25 , corrosion protector 1st stage cooler , gasket m27 ermeto , nut locking m27x2 , o ring ss15 ts12 15 , resisto flex shock mounting , piston & gp dia70 ss02 03 05 , ring pkg dia50 cyl i l , ring pkg so conn to 3 8 plug , bearing 6305 , bearing 6309 , v belt b85 , hex bolt m6x10 , split pin dia 2 5 , spring washer m8 , locking plate , packing ring , obs nrv assy 1 1 2 bsp , obs piston rings dia 60 , obs piston rings dia 70 , obs piston rings dia 100 , obs gasket hpo3 05 , air filter , plug , lp ball valve , o ring , o ring , lamellar valve 2nd stage , o ring , back up ring , low tolerance gasket , o ring , o ring , o ring for 2nd stage cylinder head , 0 160 bar pressure gauge iii stage , gasket , back up ring , air filter insert for air filter , solenoid valve , concentric valve 1st stage , filter element of hp filter 2 , resilient mounts , filter element of hp filter 1 , safety valve 4th stage , distance ring , distance ring , packing ring , gasket , gasket , packing ring , pressure washer fan wheel , overpressure valve , zin protection , liner gasket 3rd stage , gasket , hexagon head screw , gasket , gasket , dew point transmitter with 3m cable , soft starter rated 140a , temparature transmitter , one time replacement for desiccant , pre filter element , fine filter element , o ring for 1st stage cylinder head , air filter insert for air filter , valve assy b , i stage inter cooler assy , discharge valve assembly , safety valve assly iii stage , oms assy first st , oms assy 2 & 3st , valve assy nrv , water cum oil pump , auto drain valve , pr switch 0 2 7 5 bar , pressure siwtch b 42 kp6w , 1 2 bsp 150 100 hgi tg , 9bd 1 4 bsp 10 pg , ek2 anticipatory kit 2500 hrs , ek2a150m ep 10hp wc w o motor , display unit for dew point meter , water resistant pearl kg , suction air filter element

CTN :43400145 Due date: 22 Jan, 202622 Jan, 2026 NA
Tender For supply of water jacketed oven as per specification no. hemrl/css/oven/2025/6

Central Government/Public Sector

CTN :43306328 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
 Loading, Please wait...

Connect us via What's Up