Get complete information related to latest Water Line Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Line Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Line Tenders.
Tender For repair of leakage in 400/450 mm dia waterline at mangolpuri water emergency and restoration of sudden leakage/brusted waterline of 300mm dia and above at various location s in mangolpuri constituency (ac-12) under ee(d)-72.
Tender For 1)devlali- hl pf -proposed high level platform on up side with toilet, water stand facility at devlali railway station.2)devlali- hlpf- proposed high level platform on dn side with toilet, water stand facility at devlali railway station.
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For repair maintenance of ei and fans lifts pumps water supply sub station diesel generator set hvac fire fighting and fire alarm at ddu college at sector 3 dwarka new delhi sh servicing and annual maintenance contract of wtac stac units and water cooler
Tender For kota div.:-cmu-supply of 6000 gallon clean potable water per day in railway colony & station (in summer season 120 days per year) for 02 year.
Tender For supply of restoration deicing system of spillway radial gate 1 and 2 trashrack repairing servicing at cps - wall plate heater 16 kw 415 v ac length 7600 mm , skin plate heater 16 kw 415 v ac length 6825 mm , trunion arm heater 3 kw 240 v , cover plate heater 3 kw 240 v , cover plate heater 4 kw 240 v , cover plate heater 2 kw 240 v , thyristor power controller three phase current rating 50 amp , thyristor power controller single phase current rating 50 amp , thyristor power controller single phase currnet rating 40 amp , thyristor power controller single phase current rating 20 amp , temperature controller aux supply 203 v ac input 4 to 20 ma , rtd pt 100 sensor od-6 mm x l50 mm with 1 meter cable with mating connector. , propylene glycol gel industrial grade , hardware items viz. nut bolt washer water tight joint kits for cable heater tubes joints etc , installation testing and re commissioning of deiceing system of spillway radial gates no 1 and 2 and trash rack installed at dam of chutak power station as per the scope of work , annual maintenance contract two visits per year of service engineer for 5 service days for two persons including travelling charges , transportation packing and forwarding
Tender For corrigendum : supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch waterline by pvdg 3inch flange , modify 3inch waterline by pvdg 3inch nipple , modify 3inch waterline by pvdg 3 inch tee , modify 3inch waterline by pvdg 2.5 inch nipple , modify 3inch waterline by pvdg 3 and 2.5 inch socket , modify 3inch waterline by pvdg 2.5inch coupler , modify 3inch waterline by pvdg 2 inch nipple , modify 3inch waterline by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea
Tender For effecting pipeline upgradation to divert gas from seal oil traps of 10 k 105 in lpg plant and fire waterline for running ia ig compressors for cooling purpose and mitigate the bottlenecking of higher mp flash gas pressure in gsu at ongc hazira plant