Get complete information related to latest Water Pipes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Pipes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Pipes Tenders.
Tender For supply of 2 point 5mfd ceiling fan capacitor , 3m plate make roma , 4m plate make roma , 6m plate make roma , 8m plate make roma , 12m plate make roma , 3m surface type pvc box make roma , 6m surface type pvc box make roma , 8m surface type pvc box make roma , 12m surface type pvc box make roma , 1m blanking platedummy make roma , 3pin 6a socket 2m make legrand , 616a 2in 1 socket 2m make legrand , 3pin 6a socket 2m make roma , 616a 2in 1 socket 2m make roma , 3pin 6a socket 2m make mk , 6a socket 2m make mk , 6 10a switch, 1m make roma , switch mk , switch legrand , 16 20a switch, 1m make mk , 16 20a switch, 1m make roma , 6pin 6a 16a ss combined with shutter and pvc boxmake anchor , 32a single pole c type mcb make legrand , 32a 2p c type mcb make legrand , 32a 3p c type mcb make legrand , 32a 4p c type mcb make legrand , 63a 4p c type mcb make legrand , 32a spn plug industrial socket and cap with metallic enclosure box suitable for ac make legrand , insulation tape , fischer plug suitable for 1 inch drywall screw , fischer plug , screw , 1ft 58w led cool white tube lightmake cromptonsyska equivalent , 2ft 14wled cool white tube light , cool white round led false ceiling light , 12w cool white round led surface mounting light , 18w cool white round led false ceiling light , 15w cool white round led surface light , 18w cool white round led surface light , 1m fan regulator make roma , 1m 4step 04fan regulator make legrand , 2m fan regulator makemk , exhaust ventilating fan makeorient model ventilator dx , telephone instrument , telephone instrument with caller id , 5inch pvc round sheet , thermostat solar water tank , 200w led cool white flood light , 56a 3pin plug top , 15a 3pin plug top , 9inch nylon selflocking cable tie , copper wire , dol starter make l and t bch electric , annealed copper telephone flexible unarmouredcable , aa duracell batteries , distilled water , handheld cardless microphones with 2mics in each and receiver with standard accessories , capacity empty oil barrel suitable for purchasing of diesel , rotary manual hand pump with dual direction , pvc casing pipe , pvc heavy duty conduit pipe , pvc casing heavy duty conduit pipe , mseal 90gm , steel clamp
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For supply of thermocouple c c - thermocouple assembly,type k,il 2000mm , surface t c assy,type k,055 mech 0122 , thermocouple assy,type k,il 1000 mm , thermocouple assembly,type k,il 800mm , thermocouple assembly,type k,il 1250mm , n type thermocouple,inconnel600,il 750mm , n type thermocouple assy,055.mech.0518 , k type mi thermocouple,lg 152mm,dia 6mm , k type mi thermocouple,lg 117mm,dia 6mm , k type mi t c,l 275mm,055.elect.0792 , k type mi t c f periphery,055.mech.0526 , k type mi t c f stack zone,055.mech.0526 , k type mi base t c,od 6mm,055.mech.0535 , k type mi thermocouple,dia 6mm,lg 825mm , k type thermocouplesimplex,length 1200mm , k type thermocouple,simplex,length 1600m , k type thermocouple assy,length 1000mm , mineral insulated thermocouple,lg 3500mm , mineral insulated thermocouple,lg 6100mm , alumina ceramic beads,od 12.7 13.2mm , ceramic protection sheath tube , inconnel pipe 600 f thermocouple, 1100mm , inconnel pipe 600 for t c, length 1900mm , metallic t c head with ceramic,m30x1.25 , metallic t c head with ceramic, m20x1.75 , heat proof s type compensating cable,2 c * /bid number : gem/2026/b/7717132 + /dated: 29-06-2026 ' ' / bid document 1 / 32
Tender For providing of facility management services - lumpsum based - work regarding the painting and whitewashing of the 33 kv lucknow central zone lesa bhawan premises and the repair of waterpipes; civil work; consumables to be provided by service provider (inclusive in..