Get complete information related to latest Water Pump Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Pump Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Pump Motor Tenders.
Tender For replacement of 3 nos damaged/wornout 3hp submersible waterpumpmotor sets along with other related works, for irrigation of landscape in various areas of skims
Tender For lab equipment for machines lab - consumables, plc trainer kit allen bradley micro 810 plc analog and digital i/o module plc trainer with allen bradley micro810controller (2080lc1012qwb) 6 digital inputs, 2 analog inputs and 4 digital outputs 6 digital input switches 2 analog inputs with dc (0-10v) variable input 4 digital relay outputs with led indication 4 no contacts of the relays connected at outputs of the plc and a buzzer 24v operated, built-in power supply, additional 5v power supply computer connectivity to download the program using usb port with cableprofessional programming software - component connect workbench (ccw) legend printed in the pcb closed wooden cabinet, trainer kit - interfacing of discrete field devices with plc (push button, limit switch, reed switch, 3-wire proximity sensor and buzzer)sequence of operation: develop ladder logic in plc to execute the following logical relation between the input and output field devices. y = a + b + c + d y = a. b.c. d y = (a+b). (c+d) y = (a.b) + (c.d) interface contains: plc input interfacing push button (a) limit switch (b) reed switch (c) 3 wire inductive proximity sensor (d) plc output interfacing buzzer (y)closed wooden cabinet, ttrainer kit plc based conveyor system with pre warning siren interfacesequence of operation: develop and execute ladder logic in plc using an on delay timer to delay the start of a conveyor. while press the start button, activate the warning siren for pre-set time. after the pre-set time delay the warning siren turns off and the conveyor starts running. when stop button is pressed turns off the conveyorinterface details sloped conveyor system:mechanical setup: sloped conveyor integrated with 1 nos. shawl sheet metal models for material handling demonstration. plc input interfacing: 1 no. inductive proximity sensors to detect presence of shawls on the conveyor. 1 no. start push buttons one for each conveyor. 1 no. stop push buttons for individual conveyor control. 1 no. fwd/rev toggle switches to set direction of conveyor operation (forward/reverse).plc output interfacing: 1 no. siren to provide audible alarms upon detection events or conditions. 1 no. conveyor belts driven by geared dc motors controlled through plc for start/stop and direction.all components housed in a metal closed cabinet for safety integration, itrainer kit plc based water level control system interface sequence of operation: develop and execute ladder logic in plc to fill the empty tank with liquid when the start button is pressed. when liquid reaches the high level, turn off the pumpmotor and turn on the solenoid valve to drain the liquid from tank. when liquid reaches the low level, turn off the solenoid valve and turn on the pumpmotor for refilling. interface external pilot lamp with plc to indicate the operation of pumpmotor and solenoid valve. interface contains: low high level sensors as input to the plc water tap as output from the plc waterpumpmotor control using outputs of the plc water tank with sump and overhead tank model 2 levels sensor switches and 12 v pump 24 v solenoid valve to drain water, foot valve arrangement to take the water from the sump12 v and 24v power supply provided, trainer kit plc based counting of moving objects on two conveyors interfacesequence of operation: a manufacturing plant is arranged with 2 feeder conveyors for transferring the objects into the plant. develop and execute ladder logic using math instruction in plc to get the total number of objects transferred by 2 conveyors into the plant. when the count of total object has reached pre-set count value, turn on buzzer to give beep sound for 1 second and turn off the conveyors.interface details sloped conveyor system: mechanical setup: sloped conveyor integrated with 2 nos. shawl sheet metal models for material handling demonstration. plc input interfacing: 2 nos. inductive proximity sensors to detect presence of shawls on the conveyor. 2 nos. start push buttons one for eac
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - 0; hvac, l-01 the black waterpumpmotor of the evac system is non operational e-07 water droplets observed on ac plant no 1 while running conditions e-08 during operati..
Tender For annual contract for housekeeping and equipments cleaning at pps iii bawana - contract for housekeeping & equipments cleaning at pps-iii bawana for three months, clng entire flr area gt#1&2, dusting wall door window gt#1&2, washing flr gts&around, gt accries coment floor & encloser 1&2, dusting clng structural member gt#1&2, clng ent flr ar gt#1&2 air inl fil house, clng entire flr area sos 1&2 ,jop 1&2, clng entire flr area gcs 1& 2, clng entir road ,drain around gcs 1&2, dusting clng structurl membr gcs 1&2, clng entire flr area of et,pt,gbdpu, dust clng wall door win around pt,gbdpu, generator & gcb flr of unit#1 &2, clng entire flr area of exciaon room1&2, dust clng wall door win of exci room 1&2, cln enti flr area of hydn room 1&2,stg 1, dust cln wall dr wn of hyd rm gt1&2,stg1, clng entire flr area of dmcw & phe room, dust cln wall ,dr wind of dmcw & phe rm, cln enti(gtgt1&2&stgt#1)sat1&2, lt tr ar, clng entire flr area of package ac room, clng entire ground area dsb, dusting wall door window dsb, clng entire ground flr area hrsg i&ii, clng drains & roads around hrsg i&i, washing roads around hrsg i&ii, cln enti flr from gf to 3rd flr bfp bldg, clng drain & road around bfp bldg, cln ent flr ar stg hall bldg, mot&gd flr, dusting clng structural member stg hall, clng entire flr area of control room, dust cln cab wall dr wind of conl room, clng entire flr area of battery room, clng enti flr ar of cable gallery room, clng entire flr area mcc room, dusting clng structural member mcc room, clng entire flr area of nn100 room, clng entire flr area chiller room, clng entire flr area of lp co2 tank, cln toilet near by gas turbine, clng entire flr area comp house, dust clng door window., clng entire flr area of fire pump house, dust clng door window., clng entire areas of cwpp house, clng entire flr area rwr pp house, clng entire flr area gcs, clng entire flr area cooling tower &stai, gf flr i/c staircase upto ff flr, dusting clngs door window ceiling gf, 1st flr flr i/c staircase upto 2nd flr, dusting clng door window ceiling 1st flr, parking place and internal road, clean toilet, clng entire flr area gf, dusting clngs door window ceiling gf, clean toilet, clng gas turbine compartment, clng vent fan & its motor gt#1&2, cln gt accs compartment equipments 1&2, clng eqipts &pipe in so s1&2 ,jop 1&2, cln eqts &pipe gcs1&2(near gas turbine), clean bus duct & its support of gt#1&2, clng generator & gcb of unit#1 &2, clean dg set & fuel tank, cln auxs( pump, motors, pip, v/v etc), cln steam tur1& its associated aux ., clng stg 1 generator, exci encl,bus d, cln stg stm,oil,wt, pips on stgfr,motfr, cln ecw,acw,sos,vacm pp,cep mots ,v/v, clean compressor , pipe, v/v,dryers,tank, clean fire pump, motor, pipe,v/v, clean cw& acw pump, motor, pipe,v/v, clean raw waterpump, motor, pipe,v/v, clean gcs (near gail terminal) eqts,v/v, clng lci enclosure from outside, clng entire flr area gt#3&4, dusting wall door window gt#3&4, gt acces compar floor&enclos3&4, washing flr gts&around, dusting clng structural member gt#3&4, cln enti flr area gt#3&4air filter house, clng entire flr area sos 3&4 ,jop 3&4, clng entire flr area gcs 3&4, clng entir road ,drain around gcs 3&4, dusting clng structurl membr gcs 3&4, clng entire flr area of et,pt,gbdpu, dust clng wal dr windo aroud et,pt,gbdpu, generator & gcb flr of unit#3&4, cln entir flr area of exciation room3&4, dust cln wal dor windo of exciat rm 3&4, cln entr flr area of h2 rm 3&4,stg 2, dust cln wal dor of hyd rm gt 3&4,stg 2, cln entr flr area of dmcw & phe room#2, dust cln wall ,dor of dmcw & phe room#2, cln entr road(gtgt3&4, stgt lt trns area, clng entire ground flr area hrsg iii&iv, cln drains & roads around hrsg iii&iv, w