Tender For submission of a rate schedule for machinery and equipment to prepare an estimate for installing rainwater harvesting systems in stormwater lines and low lying areas along main and internal roads within the municipal corporation limits. - item name, providing and constructing recharge pit of 2.0m deep and 1.0m dia of precast rcc rings with 6.5 dia. x 25m deep bore well at the floor of recharge pit including providing and supplying one complete ai-enabled single integrated modular smart groundwater recharge unit with recharge-volume measurement, real-time clog monitoring, recharge-waterqualitymonitoring, soil quality / site suitability assessment, iot communication, ai dashboard and gis monitoring platform, suitable for urban rainwater and storm water groundwater recharge applications. the supplied unit shall be a single integrated smart recharge unit and shall not be a combination of disconnected or separately assembled devices. all field-level hardware, sensors, filtration arrangement, sedimentation section, recharge-volume measurement system, real-time clog monitoringsystem, recharge-waterqualitymonitoringsystem, iot controller, communication module, qr/gis asset identification and data communication components shall be integrated within the supplied smart recharge unit and shall operate as one complete system. the ai dashboard, gis monitoring platform, cloud hosting, sim/data communication and software support shall be digitally integrated with the supplied unit for live monitoring, alerts, analytics and reporting. internal components shall not be treated as separate payable items. the main body / modular assembly of the unit shall be made primarily from hdpe/frp / upvc or equivalent corrosion free material and shall be suitable for long-term contact with rainwater / storm water, groundwater recharge applications and repeated cleaning. the unit shall be corrosion-resistant, water-resistant, durable and easy to maintain. the unit shall be modular, removable, reusable and serviceable. the design of the unit shall enable cleaning, sediment removal, filter inspection, filter-media replacement, sensor inspection and refitting without damaging the surrounding civil structure, chamber or recharge arrangement. the unit shall have a minimum external diameter of 750 mm and minimum overall height of 2000 mm with frp cover of suitable size having 40 mt capacity. the unit shall have sufficient internal space for filtration arrangement, sediment holding, recharge-volume measurement, real-time clog monitoring, water-qualitymonitoring, iot components, sensor housing, cleaning access and maintenance. the unit shall include multistage filtration, debris arrest arrangement, first-flush / bypass provision, sedimentation and silt-management section, recharge-volume measurement system, recharge-rate monitoring, real-time clog monitoring, recharge-waterqualitymonitoring after filtration and before recharge, soil quality / site suitability assessment module, iot-based data communication, qr, gis asset identification, ai-enabled web dashboard, gis monitoring platform. the unit shall be capable of measuring, recording and reporting actual recharge volume, recharge-rate trend, sedimentation status, clogging condition, recharge-waterquality parameters, soil / site suitability parameters, unit health, sensor health, battery status, communication status and maintenance status on a web-based dashboard. the item shall be treated as one complete integrated smart unit. internal components such as hdpe/ frp modular body, filtration arrangement, sedimentation section, measurement systems, sensors, iot controller, communication module, ai dashboard, gis platform, cloud hosting and sim/data support shall not be measured or paid separately. the unit shall have authentication from any govt. institute like c.o.e.p./cw&prs/gsda etc. the unit shall be supplied with five years warranty against manufacturing defects, material defects and functional failur
Tender For corrigendum : procurement of medical consumables items for use by the cardiology department, goa medical college, bambolim - injectable cardiovascular ultrasound contrast agent comprised of lipid-coated echogenic microbubbles filled with octafluoropropane gas or equivalent approved agent (cost comparison will be based on per study cost); in remarks - please detail the dose required per study per the instructions for use, disposable electrodes designed specifically for patient monitoring, disposible electrodes designed specifically for stress testing - please quote only those that are specifically designed for stress testing, disposible electrodes designed specifically for holter monitoring - please quote only those that are specifically designed for holter monitoring, disposable defibrillator patches (anterior and posterior) for use with philips brand defibrillators, disposable radiolucent defibrillator patches (anterior and posterior) for use with philips defibrillators, printer paper roll for philips mrx defibrillator and for efficia defibrillators, thermal printing paper for sony thermal printer used with echocardiography machines (model up/d-897), ultrasound jelly for echocardiography 5 litre pack, ecg thermal printing paper for use with philips pagewriter tc20 ecg machine; philips make only, ecg thermal printing paper for use with ge mac 5500 hd ecg/stress testing machine; ge make only, ecg thermal printing paper for use with bpl cardiart 6208 view plus ecg machine; 80 mm width roll, filter for hamilton ventilator hma anti-bacterial filter, flow sensor for hamilton g5 ventilator, oxygen cell for hamilton g5 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, abg machine sensor cassette for radiometer abl 9 machine - 200 tests with 60 days validity with ph, pco2, po2, hct, na, k, ca++, chloride, lactate, abg machine ssolution pack for radiometer abl 9 machine (sp9), ventilator circuits (two limb) for adult patients, non-invasive ventilator face mask, nasal prongs for pediatric patients, normal saline 1 l pouch pack suitable for use with pressure infusor bag, normal saline 0.5 l pouch pack suitable for use with pressure infusor bag, pressure bag with manometer for iv infusion/pressure infusor bag, silk suture sterilized and packed with cutting needle 1.0 silk nw 5062 or equivalent, silk suture sterilized and packed with round body needle 1.0 silk nw 5063 or equivalent, surgical skin stapler with stapler cartridge for pacemaker pocket closure, staple remover, surgical disposible scalpel blade only number 11, surgical disposible scalpel blade only number 15, iodine impregnated antimicrobial transparent incise drape 23 x 23 cm, film transparent dressing with non-adherent pad 3 1/2 inches x 6 inches (9 x 15 cm), packing material for cath lab use 5 cm width x 200 metres roll, packing material for cath lab use 7.5 cm width x 200 metres roll, packing material for cath lab use 10 cm width x 200 metres roll, packing material for cath lab use 15 cm width x 200 metres roll, packing material for cath lab use 20 cm width x 200 metres roll, packing material for cath lab use 25 cm width x 200 metres roll, packing material for cath lab use 30 cm width x 200 metres roll, ethylene oxide (eto) gas cartridge, labelling instrument for packed items for cath lab, printer ribbon for use in labelling instrument l-1 will be calculated for labelling instrument with label rolls (total quantities), label roll for use with instrument quoted for in labelling instrument with built in eto exposure indicator, label roll for use with instrument quoted for in labelling instrument with built in steam exposure indicator, biological indicator for use in eto sterilizer, biological indicator for use with autoclave sterilizer, incubator for use with biological indicators quoted above l-1 will be calculated for incubator with total quantities of biological indicators in above t
Tender For supply of oil in water analyser spares procurement for dmp-3 to m/s. forbes marshall pvt ltd, as per mrpl tender terms and conditions - bulkhead union elbow in pp, connection 3/8" od, for inlet & outlet tube, awa-he750-fm, neoprene tube 6.4x9.6mm-imtr length, awa-he720tubec-fm cleaning pump tubing with connectors novoprene, waterqualitymonitoringsystem spare mvux card for cod analyzer at373524n, part number: awa-he170s, strainer set spares for forbes marshall cx6000 series oil in water/phenol analyser, part number:awa-me610, water detector set, cleaning reagent flow detector with cable. spares for forbes marshall cx6000 series o, part number:awa-ea330, pcx1 microprocessor without display board spares for forbes marshall cx3000, series cod/bod/tss analyser, part number: awa ea306-fm, 4-20ma double output module spares for forbes marshall cx6000 series oil in water /phenol analyser an, mpa analyzer internal & external tubing., 1)sample tube-1meter. 2) clean tube-2mtrs & pump tube with connector.3)catch pot tube-, part number:awa-cx2he111, canister s lit. spares for forbes marshall cx6000 series oil in water/phenol analyser and cx3000 seri, part number awa-ee8395, xenon lamp box set (xenon, trigger, board, filter and box)-lnternal. spares for forbes marshall cx6000 5
Tender For annual maintenance contract (non- comprehensive) for online effluent waterqualitymonitoringsystem of unit no. 1 and 2 of 2x600 mw, sstpp, mppgcl, dongalia.
Tender For corrigendum : providing of testing of waterquality - annual maintenance contract of online waterqualitymonitoringsystem operation or data transmission etc for one year; as per specification
Tender For supply of medical equipments in various locations in distt. patiala (as per detail attached) - supply, ot table, hydraulic operated with smooth gear mechanism, double cylinder loak proof, stainless steel, medical refrigerator 250-300 ltr. with shelf temperature setting (approx) +0 to +8 c, voltage 220 - 240 v, freguency 50/60 hz, ot light ceiling mounted single dome 12 led with led 50000 lux 22" dia dome with 4 reflector of 8 dia. auto spring balanced, heavy duty step down transformer. sterilizable central handle., ecg machines 12 leads single print 10-hour standby time, continuous print more than 3-hour, auto-analysis and auto-diagnosis for routine ecg parameters, built-in large capacity memory, casseta 14*x17* for pre-installed dr system for xray at mkh patiala make agfa, semi auto analyzer with built in software for the calculation and curve plotting. light source led, open system capable using all grand reagents and all the test programs should be in open mode. user interface: lcd display with touch key board, flow cell type permanent flow cell. memory >= 500 tests, in-built thermal printer, in-built thermal printer required, accessories to be supplied 1. micro pipettes (* no.) - 2 variable (5-50), (100-1000), small tips 500 nos. & large tips- 500 number, laproscopic surgical instrument set, ups 1kva offline for ultrasound machine simulated sine wave or better voltage avr mode 200-245v voltage battery mode 230vac +10%e frequency (htz) on battery 50/60hz + 0.1hz, 30 min backup, iso 14001/bis certification, biphasic defibrillator monitor 8.4" inch size screen, charging time of less than 9 seconds for maximum energy of 2 to 360 joule, synchronized & asynchronized cardio-version and having in-built thermal printer, monitoring 12 lead ecg, heart rate, spo2, & nibp, 230v, 50hz ac mains and battery capable of delivering up to 50 shocks at 200 joule, iso /en 60601-1, certified, oem warranty 3 year, boyles apparatus, 4 cyl mechanical with 3 gas system with hypoxic guard with 2 vaporizer (halothane & isoflurane), ice lined refrigerator (ilr) 144 lt 220 volt 50 hertz, in build stabilzer led (3-digit digital display), galvanized steel, stem alchol thermometer, ground clearance (min) 100 millimeter, holdover time (in a continuous external temperature of +43 degree celsius -24 hour, sets of instruments used for laparoscopy surgerya. gull bladder extractor, b. call stone spoon extractor c. 10 mm safety trocar, d. aspiration needlee. 5mm and 10 mm reducers, metallic continuous spray pump 1.5 ltr. (ganesh pump) type: hand compressor sprayer, tank: brass. tank capacity: 1.5 lit. pump barrel brass, working pressure, 40 - 45 psi, baby warmer steel tubular structure pretreated and powder coated heater rotation +90, bed tilt should be 615 , led displays, aulomatically cut off at 38 degree celsius, probe accuracy specilication: +0.1 c @ 30 c to 42 c, 200 to 240vac 50 hz supply
Tender For purchase of lab equipments for heat power engineering lab and 3d printer for mech department - five gas analyzer (exhaust gas)* portable 5-gas exhaust analyzer for automotive lab use * measurement of co (0 10%), co (0 20%), hc (0 20000 ppm), o (0 25%), nox (0 5000 ppm) * gas sampling rate: 1 litre/min * response time: 5 seconds * warm-up time: 3 minutes * display: lcd * input: membrane keypad* operating temperature: 0-50 c * power consumption: 25 w, operates on 230v ac / battery * supplied with sampling probe, filters, and carrying case, 3 d printing machine build volume(wxdxh) 256 x 256 x 256 mm shell enclosed (plastic & glass) hot end all metal nozzle 0.4 mm stainless steel included max hot end temperature 300 nozzle diameter 0.4 mm (included) 0.2 mm, 0.6 mm, 0.8 mm build plate compatibility textured pei plate, cool plate, engineering plate, high temperature plate max build plate temperature 100 max speed of tool head 500 mm/s max acceleration of tool head 20 m/s supported filament pla, petg, tpu, pva, pet, abs, asa chamber monitoring camera low rate camera 1280 x 720/0.5fps timelapse supported filament run out sensor :yes control board fan closed loop control auxiliary part cooling fan closed loop control air filter activated carbon filter
Tender For amtc of ephs in 15 mld stp ue kurukshetra supply of online data transfer to cpcb and hspcb server for existing system of waterqualitymonitoringsystems parameter is bod cod tss ph and etc of 15 mld stp kurukshetra complete all other work contingent