Web Analytics Made Easy - StatCounter

Water Stand Post Tenders

Get complete information related to latest Water Stand Post Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Stand Post Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Stand Post Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41082560 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For repairing and maintenance of existing water stand posts submersible borings including supply of all necessary materials under water supply head from agency/contractor/supplier/ service provider/ seller, for total 45 wards under nagar nigam, munger from ward no. 1 to 45 (rate proposed will be inclusive of all taxes & other charges) (15th finance 6th state finance head)

Central Government/Public Sector

CTN :41101737 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For providing of repair and overhauling service - both fire damper operating handles; both fire damper operating handles; no; service provider premises

Central Government/Public Sector

CTN :40636354 Due date: 17 Jul, 202517 Jul, 2025 4.90 Crore
Location: Goa - Goa Goa - Goa
Tender For bid to ras armo 2025 27 sh operation and maintenance of hvac system at split at goa airport - manpower for operation and day to day maintenance , camc 4nos x 600 tr chiller , camc 1no x 400 tr chiller , camc anciliary equipments of hvac system , treatment and analysis of hvac condensor water , treatment and analysis of hvac chilled water , supply and replacement of chiller compressor lube oil for carrier make , supply and replacement of chiller compressor lube oil for blue star make , replacement of old worn out ahu air filter with new filter , cmc of ahu fire smoke damper, control panel, actuator , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-500 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-400 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-350 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-300 mm dia valve , replacement of ci butterfly valve for condensor chilled water including dismantling of faulty valve-150 mm dia valve , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 24 swg , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 22 swg , supply,fabrication,installation, testing and commissioning of site fasbricated gss sheet thickness 20 swg , supply and fixing 50 mm thickness closed cell nitrile rubber with insulation provided with uv protected aluminium based cladding with cold setting adhesive on exposed outdoor ducting , supply and fixing 50 mm thickness closed cell nitrile rubber with insulation with factory laminated aluminium foil by applying suitable cold setting adhesive on indoor ducting above false ceiling , cmc of existing uvgi ultra violet germicidal irradiation system provided inside ahu exluding uv lamp reflector and uv ballast. , supply of uv lamp for existing uvgi provided inside ahu , supply of reflector for existing uvgi provided inside ahu , supply of uv ballast for existing uvgi provided inside ahu , cmc of car parking ventilation system installed at mlcp including axial flow type jet fans , cmc of window split type airconditioners cassette type of all makes of 1 point 5 ton 2 ton capacity with single phase supply at different locations including providing for first year , cmc of window split type airconditioners cassette type of all makes of 1 point 5 ton 2 ton capacity with single phase supply at different locations when required for second year , comprehensive maintenance contract of split multi split type cassette typetower type airconditioners of all makes of 3 ton capcity with 3 phase supply etc as and when required for first year , comprehensive maintenance contract of split multisplit type cassette type tower type airconditioners of all makes of 3 ton capcity with 3 phase supply etc as and when required for second year , cmc for vrf system indoor unit varying from 1 ton - 2 ton installed in new admin block , cmc for vrf system indoor unit varying from 3tr installed in pre security area , cmc for vrf system indoor unit varying from 4tr installed in pre security area , cmc for vrf system indoor unit varying from 4tr installed in 1st floor mlcp cisf portion , cmc for vrf system indoor unit varying from 4tr installed in 2nd floor mlcp, aai offices , cmc for vrf system indoor unit varying from 2 ton and cassette unit of 3 ton installed in apron control room. , comprehensive maintenance contract for vrv variable refrigerant volume system consisting of 03 nos of 3point2 tr cassette ac indoor unit, including all related accessories installed in aocc room , comprehensive maintenance contract for vrv variable refrigerant volume system consisting of12 nos outdoor units of 17point7kw each rating, installed in present dsha , comprehensive maintenance con

CTN :40567938 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For corrigendum : supply of mgsd spares - epoxy 5 minutes adhesive,over voltage relay,seat bleeder,oil pressure sensor (servicing kit),oetiker type clamp,oetiker type clamp,clamp,spacer tube,rubber,nipple (eng),nipple,tube 160mm,air hose,damper,fuel line,hose coolant 50x60,safety house,hose,filter cpapcitor,shim 8.2x1.5,brake fluid cyl,pressure line 45x600wg and fire sleeve,hose (mtr),hose,placard, altitude speed list,placard canopy jettision,bolt with hole,tail skid rubber,lithium grease,loctite 603 green,overflow bottle,v-belt,adapter,kniestick,spinner screw,tube,nipple,bolt,rudder pedal adjustment,spacer tube,rotax bowden cable,bowden cable choke,seat cushion right,seat cushion left,piano switch(load switch) acl,inst,light, fuel pump,piano switch mode selector(flight/soaring),self locking nut,cooolant hose(water cooler coolant bend rh),gasket ring 10x14,tube 66mm, | quantity - 1747,916384

CTN :40953797 Due date: 19 Jul, 202519 Jul, 2025 7.39 Lacs
Tender For naveen mandi sthal haldaur mein re-constraction of damage boundarywall and 01 nos new water stand post ka nirman karye mandi haldur

CTN :40966577 Due date: 12 Jul, 202512 Jul, 2025 1.80 Crore
Tender For e-procurement tender for fire renovation work for lab, electrical control panel, and air handling system repair and restoration - construction of puf panel room, ahu control panel shifting, ahu main lt panel, cable tray 300x50mm (ff), termination 3.5c x 400 sq.mm, termination 3c x 2.5 sq.mm, termination 4c x 25 sq.mm, aluminium cable 3.5c x 400 sq. mm, flexible cable 3c x 2.5 sq. mm, copper, ar. 4c x 25 sq. mm, cable tray 150x50mm, cable tray 300x50mm, cable termination 10 sqmm, cable termination 6 sqmm, cable termination 2.5 sqmm, copper, ar. cable 3c x 10 sq. mm, copper, ar. cable 3c x 6 sq. mm, copper, ar. cable 3c x 2.5 sq. mm, core cutting civil hole packing, wall finishing after duct work, wall opening for duct entry, civil bed for ac outdoor installation, lifting , shifting & transportation, swing glass door 1000 x 2100mm, gi powder coated accessories, wall panel 50mm (ff), view glass 750 x 1000mm, view glass 1000 x 1000mm, aluminium internal/external corners 3d & 2d, extruded aluminium covings, silicon sealant, ceiling support & accessories, gi powder coated c channels, l angles, bottom tracks, ceiling panel 50mm, wall panel 50mm, double door 1500 x 2100, dynamic pass box for the cleanroom, coving & 2d , 3d, riser panel, suitable vfd, duct supporting accessories, supply & installation of damper , collar & canvas, supply & installation of duct & insulation, accessories for the condensing unit, odu for fau, suitable hepa filter, eau 8900 cfm at 150 mm wc, fau 8900 cfm at 150 mm wc

corporations/Associations/Others

CTN :40581173 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For corrigendum : supply of 5.5tr split ductable unit btu per h 66000 high static duct able units minimum 78 pascal external static pressure , copper referigerent pipe , 7.0 core x 2.5 sqmm , refrigerant r410a , n2 pressure gas charge , 50 mm dia pvc drain pipes , 40 mm dia pvc drain pipes , gss sheet metal 24 swg , 19 mm thick duct thermal insulation , duct accounstic lining inside the ducts with 10mm thick class-1 open cell nitrile sheet , linear discreet continious grill , coller damper , 150 mm depth fire retardent canvas , civil works
 Loading, Please wait...

Connect us via What's Up